Characteristic wave detection in ECG signal using morphological transform
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: Detection of characteristic waves, such as QRS complex, P wave and T wave, is one of the essential tasks in the cardiovascular arrhythmia recognition from Electrocardiogram (ECG). Methods: A multiscale morphological derivative (MMD) transform-based singularity detector, is developed for the detection of fiducial points in ECG signal, where these points are related to the characteristic waves such as the QRS complex, P wave and T wave. The MMD detector is constructed by substituting the conventional derivative with a multiscale morphological derivative. Results: We demonstrated through experiments that the Q wave, R peak, S wave, the onsets and offsets of the P wave and T wave could be reliably detected in the multiscale space by the MMD detector. Compared with the results obtained via with wavelet transform-based and adaptive thresholding-based techniques, an overall better performance by the MMD method was observed. Conclusion: The developed MMD method exhibits good potentials for automated ECG signal analysis and cardiovascular arrhythmia recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization of signals from multiscale edges
Mallat, S., & Zhong, S. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.142909 · Cited by 3,200 · cited 1×
“The fiducial points in ECG signal, such as the Q wave, R peak, S wave, the onsets and offsets of the P wave and T wave, can be regarded as such singular points [16,17].”
Image Analysis Using Mathematical Morphology
Haralick, R. M., Sternberg, S. R., & Zhuang, X. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767941 · Cited by 2,710
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597 · cited 3×
“In addition, the problem of position deviation existed in wavelet transform-based techniques [10] can be avoided due to the nonlinearity of morphological transform.”
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142 · cited 1×
“A significant amount of research effort has been devoted to the automated detection of the fiducial (reference) points of the ECG characteristic waves [2-12].”
Laguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.648140 · Cited by 606 · cited 2×
“The proposed morphological approach for the characteristic wave detection in ECG signal was tested using the first ECG leads from the MIT-BIH arrhythmia database [21] and the QT database [ 22 ]http://www.physionet.org, which were developed with the aim to be benchmarking references for automated analysis of ECG.”
Automatic Detection of Wave Boundaries in Multilead ECG Signals: Validation with the CSE Database
Laguna, P., Jané, R., & Caminal, P. (1994) · Computers and Biomedical Research · doi:10.1006/cbmr.1994.1006 · Cited by 490 · cited 1×
“A significant amount of research effort has been devoted to the automated detection of the fiducial (reference) points of the ECG characteristic waves [2-12].”
An approach to cardiac arrhythmia analysis using hidden Markov models
Coast, D. A., Stern, R. M., Cano, G. G., & Briller, S. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.58593 · Cited by 475
Scale-space properties of the multiscale morphological dilation-erosion
Jackway, P. T., & Deriche, M. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.476009 · Cited by 292 · cited 2×
“By choosing a flat structuring function, where gs(x) = 0, x ∈ G, where G = {x: ||x|| ≤ s} [14], the above multiscale morphological derivative transform described by Equation (6) is simplified to the following process: Choose a moving window with a length of (2s + 1) samples and find the maximum and minimum values in t…”
New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications
Laguna, P., Thakor, N. V., Caminal, P., Jané, R., Yoon, H.-R., Bayés de Luna, A., Marti, V., & Guindo, J. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441680 · Cited by 228 · cited 1×
“A significant amount of research effort has been devoted to the automated detection of the fiducial (reference) points of the ECG characteristic waves [2-12].”
ECG signal conditioning by morphological filtering
Sun, Y., Chan, K. L., & Krishnan, S. M. (2002) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(02)00034-3 · Cited by 222 · cited 1×
“The preprocessing in step 1 is performed as follows: where fo is the original input signal; fb is the baseline drift signal; f is the signal after preprocessing; o is morphological opening operator; • is morphological closing operator; structuring elements, Bo, Bc and B, are selected based on the properties of ECG cha…”
Self-citation
Cited by
RAIM: Recurrent Attentive and Intensive Model of Multimodal Patient Monitoring Data
Xu, Y., Biswal, S., Deshpande, S. R., Maher, K. O., & Sun, J. (2018) · Proceedings of the 24th ACM SIGKDD International Conference on Knowledge Discovery & Data Mining · doi:10.1145/3219819.3220051 · Cited by 144
“Traditional signal processing algorithms were widely used for analyzing patient monitoringdata,suchasP-QRS-Tdetection[44]orRRinterval/heart ratevariability(HRV)extraction 1 for ECG signal processing.”
Smart-watches: a potential challenger to the implantable loop recorder?
Carpenter, A., & Frontera, A. (2016) · Europace · doi:10.1093/europace/euv427 · Cited by 86
Metadata
- Authors
- Sun, Y., Chan, K. L., & Krishnan, S. M.
- Venue
- BMC Cardiovascular Disorders
- Published
- 2005-09-20
- Volume
- 5
- Issue
- 1
- Pages
- 28-28
- ISSN
- 1471-2261 (ISSN-L)
- OpenAlex
- W1623295311
- Cited by
- 177
- References
- 16
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.