CoChat

The sensitivity of real-time PCR amplification targeting invasive Salmonellaserovars in biological specimens

Open access
Nga, Tran Vu Thieu, Karkey, Abhilasha, Dongol, Sabina, Thuy, Hang Nguyen, Dunstan, Sarah, Holt, Kathryn, Tu, Le Thi Phuong, Campbell, James I, Chau, Tran Thuy, Chau, Nguyen Van Vinh, Arjyal, Amit, Koirala, Samir, Basnyat, Buddha, Dolecek, Christiane, Farrar, Jeremy, Baker, Stephen · 2010 · BMC Infectious Diseases
Cited by 121

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: PCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella serovars, which cause enteric fever, can be commonly cultured from the blood of infected patients. Yet, the isolation of invasive Salmonella serovars from blood is protracted and potentially insensitive. Methods: We developed and optimised a novel multiplex three colour real-time PCR assay to detect specific target sequences in the genomes of Salmonella serovars Typhi and Paratyphi A. We performed the assay on DNA extracted from blood and bone marrow samples from culture positive and negative enteric fever patients. Results: The assay was validated and demonstrated a high level of specificity and reproducibility under experimental conditions. All bone marrow samples tested positive for Salmonella, however, the sensitivity on blood samples was limited. The assay demonstrated an overall specificity of 100% (75/75) and sensitivity of 53.9% (69/128) on all biological samples. We then tested the PCR detection limit by performing bacterial counts after inoculation into blood culture bottles. Conclusions: Our findings corroborate previous clinical findings, whereby the bacterial load of S. Typhi in peripheral blood is low, often below detection by culture and, consequently, below detection by PCR. Whilst the assay may be utilised for environmental sampling or on differing biological samples, our data suggest that PCR performed directly on blood samples may be an unsuitable methodology and a potentially unachievable target for the routine diagnosis of enteric fever.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2334-10-125

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 121

Metadata

Authors
Nga, T. V. T., Karkey, A., Dongol, S., Thuy, H. N., Dunstan, S., Holt, K., Tu, L. T. P., Campbell, J. I., Chau, T. T., Chau, N. V. V., Arjyal, A., Koirala, S., Basnyat, B., Dolecek, C., Farrar, J., & Baker, S.
Venue
BMC Infectious Diseases
Published
2010-05-21
Volume
10
Issue
1
Pages
125-125
ISSN
1471-2334 (ISSN-L)
OpenAlex
W2054361846
Cited by
121
References
2
FWCI
10.41
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The sensitivity of real-time PCR amplification targeting invasive Salmonellaserovars in biological specimens. https://app.cochat.ai/papers/10.1186/1471-2334-10-125
The paper
Nga, T. V. T., Karkey, A., Dongol, S., Thuy, H. N., Dunstan, S., Holt, K., Tu, L. T. P., Campbell, J. I., Chau, T. T., Chau, N. V. V., Arjyal, A., Koirala, S., Basnyat, B., Dolecek, C., Farrar, J., & Baker, S. (2010). The sensitivity of real-time PCR amplification targeting invasive Salmonellaserovars in biological specimens. BMC Infectious Diseases. https://doi.org/10.1186/1471-2334-10-125

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.