Determination of decimal reduction time (D value) of chemical agents used in hospitals for disinfection purposes
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Prior to the selection of disinfectants for low, intermediate and high (sterilizing) levels, the decimal reduction time, D-value, for the most common and persistent bacteria identified at a health care facility should be determined. METHODS: The D-value was determined by inoculating 100 mL of disinfecting solution with 1 mL of a bacterial suspension (10(4)-10(5) CFU/mL for vegetative and spore forms). At regular intervals, 1 mL aliquots of this mixture were transferred to 8 mL of growth media containing a neutralizing agent, and incubated at optimal conditions for the microorganism. RESULTS: The highest D-values for various bacteria were determined for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0)--E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min) and 0.1% for B. stearothermophilus (D = 3.5 min) and B. subtilis (D = 3.2 min); (iii) 2.0% glutaraldehyde (pH 7.4)--B. stearothermophilus, B. subtilis (D = 25 min) and E. coli (D = 7.1 min); (iv) 0.5% formaldehyde (pH 6.5)--B. subtilis (D = 11.8 min), B. stearothermophilus (D = 10.9 min) and A. calcoaceticus (D = 5.2 min); (v) 2.0% chlorhexidine (pH 6.2)--B. stearothermophilus (D = 9.1 min), and at 0.4% for E. cloacae (D = 8.3 min); (vi) 1.0% Minncare (peracetic acid and hydrogen peroxide, pH 2.3)--B. stearothermophilus (D = 9.1 min) and E. coli (D = 6.7 min). CONCLUSIONS: The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations showed that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasizes the importance and need to develop routine and novel programs to evaluate product utility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APIC guidelines for handwashing and hand antisepsis in health care settings
Larson, E. L. (1995) · American Journal of Infection Control · doi:10.1016/0196-6553(95)90070-5 · Cited by 771
Cited by
Clinically Relevant Chromosomally Encoded Multidrug Resistance Efflux Pumps in Bacteria
Piddock, L. J. V. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.2.382-402.2006 · Cited by 1,231
Non-thermal plasma technologies: New tools for bio-decontamination
Moreau, M., Orange, N., & Feuilloley, M. G. J. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.08.001 · Cited by 657
Clasen, T., & Edmondson, P. (2006) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2005.11.004 · Cited by 188
Sporicidal Activity of Synthetic Antifungal Undecapeptides and Control of Penicillium Rot of Apples
Badosa, E., Ferré, R., Francés, J., Bardají, E., Feliu, L., Planas, M., & Montesinos, E. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.00711-09 · Cited by 67
Metadata
- Authors
- Mazzola, P. G., Penna, T. C. V., & da S Martins, A. M.
- Venue
- BMC Infectious Diseases
- Published
- 2003-10-17
- Volume
- 3
- Issue
- 1
- Pages
- 24-24
- ISSN
- 1471-2334 (ISSN-L)
- OpenAlex
- W2118376148
- Cited by
- 119
- References
- 1
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.