A commercial line probe assay for the rapid detection of rifampicin resistance in Mycobacterium tuberculosis: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Background: Mycobacterium tuberculosis is a leading cause of death worldwide. In multi-drug resistant tuberculosis (MDR-TB) infectiousness is frequently prolonged, jeopardizing efforts to control TB. The conventional tuberculosis drug susceptibility tests are sensitive and specific, but they are not rapid. The INNO-LiPA Rif. TB®(LiPA) is a commercial line probe assay designed to rapidly detect rifampicin resistance, a marker of MDR-TB. Although LiPA has shown promising results, its overall accuracy has not been systematically evaluated. Methods: We did a systematic review and meta-analysis to evaluate the accuracy of LiPA for the detection of rifampicin-resistant tuberculosis among culture isolates and clinical specimens. We searched Medline, Embase, Web of Science, BIOSIS, and Google Scholar, and contacted authors, experts and the manufacturer. Fifteen studies met our inclusion criteria. Of these, 11 studies used culture isolates, one used clinical specimens, and three used both. We used a summary receiver operating characteristic (SROC) curve and Q* index to perform meta-analysis and summarize diagnostic accuracy. Results: Twelve of 14 studies that applied LiPA to isolates had sensitivity greater than 95%, and 12 of 14 had specificity of 100%. The four studies that applied LiPA directly to clinical specimens had 100% specificity, and sensitivity that ranged between 80% and 100%. The SROC curve had an area of 0.99 and Q* of 0.97. Conclusion: LiPA is a highly sensitive and specific test for the detection of rifampicin resistance in culture isolates. The test appears to have relatively lower sensitivity when used directly on clinical specimens. More evidence is needed before LiPA can be used to detect MDR-TB among populations at risk in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405 · cited 1×
“Overall diagnostic performance of a test can be judged by the position and appearance of the SROC curve, which is fitted by using a regression model proposed by Moses et al [ 25 ].”
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340 · cited 1×
“We performed meta-analyses in accordance with published guidelines [21,22].”
Systematic reviews of evaluations of diagnostic and screening tests
(2001) · Europe PMC (PubMed Central) · Cited by 850
Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
Walter, S. D. (2002) · Statistics in Medicine · doi:10.1002/sim.1099 · Cited by 672 · cited 3×
“An AUC of one represents perfect discriminatory ability, while a Q* index of one represents perfect accuracy [24].”
InfluentialExploring sources of heterogeneity in systematic reviews of diagnostic tests
Lijmer, J. G., Bossuyt, P. M. M., & Heisterkamp, S. H. (2002) · Statistics in Medicine · doi:10.1002/sim.1185 · Cited by 446 · cited 1×
“Despite variations in patient populations, all 15 studies yielded consistently high estimates of sensitivity and specificity, so heterogeneity was not a concern in this metaanalysis [26].”
Rossau, R., Traore, H., De Beenhouwer, H., Mijs, W., Jannes, G., De Rijk, P., & Portaels, F. (1997) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.41.10.2093 · Cited by 231 · cited 14×
“tuberculosis complex, five overlapping wild-type S probes, and four R probes for detecting specific mutations of resistant genotypes) immobilized on nitrocellulose paper strips [7].”
InfluentialDe Beenhouwer, H., Lhiang, Z., Jannes, G., Mijs, W., Machtelinckx, L., Rossau, R., Traore, H., & Portaels, F. (1995) · Tubercle and Lung Disease · doi:10.1016/0962-8479(95)90009-8 · Cited by 220 · cited 6×
“As illustrated in figure 2, of the four studies that tested LiPA directly on clinical specimens [8,10,11,19], sensitivity estimates, although more variable than specificity, are consistently high (80% to 100%) with one study [11] reporting a sensitivity of 100%.”
InfluentialHeifets, L. B., & Cangelosi, G. A. (1999) · PubMed · Cited by 177
Watterson, S. A., Wilson, S. M., Yates, M. D., & Drobniewski, F. A. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.7.1969-1973.1998 · Cited by 162 · cited 9×
“As illustrated in figure 2, of the four studies that tested LiPA directly on clinical specimens [8,10,11,19], sensitivity estimates, although more variable than specificity, are consistently high (80% to 100%) with one study [11] reporting a sensitivity of 100%.”
InfluentialTraore, H., Fissette, K., Bastian, I., Devleeschouwer, M. J., & Portaels, F. (2000) · PubMed · Cited by 152
Hirano, K., Abe, C., & Takahashi, M. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.8.2663-2666.1999 · Cited by 150 · cited 5×
“Rifampicin works by binding to the beta-subunit of the RNA polymerase (coded for by the rpoB gene), inhibiting protein transcription [ 3 ].”
InfluentialÇavuşoğlu, C., Hilmioğlu, S., Güneri, S., & Bilgiç, A. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.12.4435-4438.2002 · Cited by 137 · cited 2×
“DNA sequencing studies have shown that greater than 95% of the RIF-resistant strains have mutations within an 81 base pair hot-spot region (codons 507–533) of the rpoB gene [ 4 ].”
Drobniewski, F. A., & Wilson, S. M. (1998) · Journal of Medical Microbiology · doi:10.1099/00222615-47-3-189 · Cited by 123 · cited 1×
“It is estimated that more than 90% of RIF-resistant TB is also resistant to INH, making RIF-resistance a good surrogate marker for MDR-TB [4, 6 ].”
Systematic reviews of diagnostic test evaluations: what's behind the scenes?
Pai, M. (2004) · Evidence-Based Medicine · doi:10.1136/ebm.9.4.101 · Cited by 86
Self-citationRapid alternative methods for detection of rifampicin resistance in Mycobacterium tuberculosis
Lemus, D., Martin, A., Montoro, E., Portaels, F., & Palomino, J. C. (2004) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkh320 · Cited by 75 · cited 6×
“Six studies [3,7-9,15,18] used proportion method, six studies [5,10-12,14,17] used BACTEC 460, two studies [13,19] used both proportion method and BACTEC 460, and one study [16] used minimum inhibitory concentration (MIC) method as the reference test.”
InfluentialAhmad, S., Mokaddas, E. M., & Fares, E. (2002) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/s0732-8893(02)00457-1 · Cited by 63 · cited 7×
“A number of studies [3, 5 ,7-19] have evaluated the diagnostic accuracy of LiPA for detecting RIF resistance in diverse geographic settings.”
InfluentialSomoskövi, Á., Qunfeng, S., Mester, J., Tanner, C., Hale, Y. M., Parsons, L. M., & Salfinger, M. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.7.2822-2826.2003 · Cited by 51 · cited 5×
“Six studies [3,7-9, 15 ,18] used proportion method, six studies [5,10-12,14,17] used BACTEC 460, two studies [13,19] used both proportion method and BACTEC 460, and one study [16] used minimum inhibitory concentration (MIC) method as the reference test.”
InfluentialSystematic reviews of diagnostic test evaluations: What's behind the scenes?
Pai, M., Michael McCulloch, L., Wayne Enanoria, M., & John M. Colford Jr., M. (2004) · ACP Journal Club · doi:10.7326/acpjc-2004-141-1-a11 · Cited by 43 · cited 1×
“We performed meta-analyses in accordance with published guidelines [21,22].”
Self-citationSrivastava, K., Das, R., Jakhmola, P., Gupta, P., Chauhan, D. S., Sharma, V. D., Singh, H. B., Sachan, A. S., & Katoch, V. M. (2004) · PubMed · Cited by 24
Cited by
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Lewinsohn, D. M., Leonard, M. K., LoBue, P. A., Cohn, D. L., Daley, C. L., Desmond, E., Keane, J., Lewinsohn, D. A., Loeffler, A. M., Mazurek, G. H., et al. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/ciw694 · Cited by 992
Self-citationLawn, S. D., & Zumla, A. I. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62173-3 · Cited by 751
GenoType MTBDR assays for the diagnosis of multidrug-resistant tuberculosis: a meta-analysis
Ling, D. I., Zwerling, A. A., & Pai, M. (2008) · European Respiratory Journal · doi:10.1183/09031936.00061808 · Cited by 340
Self-citationMaartens, G., & Wilkinson, R. J. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61262-8 · Cited by 245
Metadata
- Authors
- Morgan, M., Kalantri, S., Flores, L., & Pai, M.
- Venue
- BMC Infectious Diseases
- Published
- 2005-07-28
- Volume
- 5
- Issue
- 1
- Pages
- 62-62
- ISSN
- 1471-2334 (ISSN-L)
- OpenAlex
- W2103808584
- Cited by
- 243
- References
- 21
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.