Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

Open access
Thomaes, Tom, Thomis, Martine, Onkelinx, Steven, Coudyzer, Walter, Cornelissen, Véronique, Vanhees, Luc·2012·BMC Medical Imaging

Abstract

Background: The increasing age of coronary artery disease (CAD) patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US) technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods: 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT) on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results: An intraclass correlation coefficient (ICC) of 0.97 ((95%CL: 0.92 - 0.99) was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97). The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66) resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001) and assessed with US (r = 0.49, p < 0.05). Muscle strength parameters were also significantly correlated with muscle diameter assessed with both techniques (range r = 0.45-r = 0.61, p < 0.05). Conclusions: Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2342-12-7

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 158

Metadata

Authors
Thomaes, T., Thomis, M., Onkelinx, S., Coudyzer, W., Cornelissen, V., & Vanhees, L.
Venue
BMC Medical Imaging
Published
2012-04-02
Volume
12
Issue
1
Pages
7-7
ISSN
1471-2342 (ISSN-L)
OpenAlex
W2074280245
Cited by
158
References
3
FWCI
4.15
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients. https://app.cochat.ai/papers/10.1186/1471-2342-12-7
The paper
Thomaes, T., Thomis, M., Onkelinx, S., Coudyzer, W., Cornelissen, V., & Vanhees, L. (2012). Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients. BMC Medical Imaging. https://doi.org/10.1186/1471-2342-12-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.