Tillquist, Maggie, Kutsogiannis, Demetrios J., Wischmeyer, Paul E., Kummerlen, Christine, Leung, Roger, Stollery, Daniel, Karvellas, Constantine J., Preiser, Jean‐Charles, Bird, Nora, Kozar, Rosemary, Heyland, Daren K.·2014·Journal of Parenteral and Enteral Nutrition

Abstract

Background : Critically ill patients commonly experience skeletal muscle wasting that may predict clinical outcome. Ultrasound is a noninvasive method that can measure muscle quadriceps muscle layer thickness (QMLT) and subsequently lean body mass (LBM) at the bedside. However, currently the reliability of these measurements are unknown. The objectives of this study were to evaluate the intra‐ and interreliability of measuring QMLT using bedside ultrasound. Methods : Ultrasound measurements of QMLT were conducted at 7 centers on healthy volunteers. Trainers were instructed to perform measurements twice on each patient, and then a second trainee repeated the measurement. Intrarater reliability measured how consistently the same person measured the subject according to intraclass correlation (ICC). Interrater reliability measured how consistently trainer and trainee agreed when measuring the same subject according to the ICC. Results : We collected 42 pairs of within operator measurements with an ICC of .98 and 78 pairs of trainer‐to‐trainee measurements with an ICC of .95. There were no statistically significant differences between the trainer and trainee results (trainer and trainee mean = −0.028 cm, 95% CI = −0.067 to −0.011, P = .1607). Conclusions : Excellent intra‐ and interrater reliability for ultrasound measurements of QMLT in healthy volunteers was observed when performed by a range of providers with no prior ultrasound experience, including dietitians, nurses, physicians, and research assistants. This technique shows promise as a method to evaluate LBM status in ICU or hospital settings and as a method to assess the effects of nutrition and exercise‐based interventions on muscle wasting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0148607113501327

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 281

Metadata

Authors
Tillquist, M., Kutsogiannis, D. J., Wischmeyer, P. E., Kummerlen, C., Leung, R., Stollery, D., Karvellas, C. J., Preiser, J., Bird, N., Kozar, R., & Heyland, D. K.
Venue
Journal of Parenteral and Enteral Nutrition
Publisher
Wiley
Published
2013-08-26
Volume
38
Issue
7
Pages
886-890
ISSN
  • 0148-6071 (ISSN-L)
  • 1941-2444
OpenAlex
W2094825334
Cited by
281
References
13
FWCI
6.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bedside Ultrasound Is a Practical and Reliable Measurement Tool for Assessing Quadriceps Muscle Layer Thickness. https://app.cochat.ai/papers/10.1177/0148607113501327
The paper
Tillquist, M., Kutsogiannis, D. J., Wischmeyer, P. E., Kummerlen, C., Leung, R., Stollery, D., Karvellas, C. J., Preiser, J., Bird, N., Kozar, R., & Heyland, D. K. (2014). Bedside Ultrasound Is a Practical and Reliable Measurement Tool for Assessing Quadriceps Muscle Layer Thickness. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607113501327

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.