The role of endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) for qualitative diagnosis of mediastinal and hilar lymphadenopathy: a prospective analysis.
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: Recently EBUS-TBNA, which has a sensitivity of 94.6%, specificity of 100% and diagnostic accuracy rate of 96.3% as previously reported, has been widely used for patients with mediastinal and hilar lymphadenopathy or suspected lung cancer to get accurate diagnosis. The purpose of the current study was to evaluate the usefulness of EBUS-TBNA in obtaining cytological and histological diagnosis of mediastinal and hilar lymph nodes compared to the results obtained with conventional mediastinoscopy as previously reported, and to assess the relationship of diagnostic accuracy and number of passes and size of lymph nodes. Methods: 101 patients with mediastinal and hilar lymphadenopathy or suspected lung cancer in our institution were included in this prospective study. EBUS-TBNA was performed in all cases. The final diagnosis was confirmed by cytology, surgical results, and/or clinical follow-up for at least 6 months. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated using standard formulas. Results: In 101 patients, EBUS-TBNA was successfully performed to obtain samples from 225 lymph nodes, 7 lung masses, 1 mediastinal mass and 2 esophageal masses. 63 malignant tumors and 38 benign diseases were confirmed. Epidermal growth factor receptor mutation was detected in 10 biopsy samples, and epidermal growth factor receptor mutation was detected in 4 cases. With respect to the correct diagnosis of mediastinal and hilar lymphadenopathy, EBUS-TBNA had a sensitivity of 95.08%, specificity of 100%, positive predictive value of 100%, negative predictive value of 93.02%, and overall accuracy of 97.02%. The relationship of diagnostic accuracy and number of lymph node passes or size of lymph nodes was both insignificant (p = 0.27; p = 0.23). The procedure was uneventful without complications. Conclusions: EBUS-TBNA is an accurate and safe tool in diagnosis of mediastinal and hilar lymphadenopathy. It cannot completely replace mediastinoscopy, it may indeed reduce the number of mediastinoscopy procedures. In some cases, it can necessarily be the first-line procedure before mediastinoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This technique has been shown to increase the confidence level of cytopathologists in the diagnosis of lymphadenopathy [33, 34]”
From Improving diagnosis of tuberculous lymphadenitis by combination of cytomorphology and MPT64 immunostaining on cell blocks from the fine needle aspirates (2022) · cites this paper as [34]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yasufuku, K., Chiyo, M., Sekine, Y., Chhajed, P. N., Shibuya, K., Iizasa, T., & Fujisawa, T. (2004) · Chest · doi:10.1378/chest.126.1.122 · Cited by 710 · cited 1×
“Real-time endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) is a new technique that combines endoscopic visualization with high frequency ultrasound imaging, which is used to obtain cytological and histological samples of lesions adjacent to the tracheobronchial tree [ 2-4 ].”
MethodInvasive Mediastinal Staging of Lung Cancer
Detterbeck, F. C., Jantz, M. A., Wallace, M., Vansteenkiste, J., & Silvestri, G. A. (2007) · Chest · doi:10.1378/chest.07-1362 · Cited by 685
Yasufuku, K., Pierre, A., Darling, G., de Perrot, M., Waddell, T., Johnston, M., da Cunha Santos, G., Geddie, W., Boerner, S., Le, L. W., et al. (2011) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.08.037 · Cited by 563
Endobronchial ultrasound guided transbronchial needle aspiration for staging of lung cancer
Yasufuku, K., Chiyo, M., Koh, E., Moriya, Y., Iyoda, A., Sekine, Y., Shibuya, K., Iizasa, T., & Fujisawa, T. (2005) · Lung Cancer · doi:10.1016/j.lungcan.2005.07.013 · Cited by 483 · cited 2×
“As Yasufuku and colleagues [4] reported, EBUS-TBNA had a sensitivity of 94.”
BackgroundMethodInvasive Staging of Non-small Cell Lung Cancer*
Toloza, E. M., Harpole, L., Detterbeck, F., & McCrory, D. C. (2003) · Chest · doi:10.1378/chest.123.1_suppl.157s · Cited by 395 · cited 2×
“Furthermore, though viewed as the gold standard for mediastinal nodal assessment, the diagnostic sensitivity of cervical mediastinoscopy is only 78-81%, which is inferior to that of EBUS-TBNA, as reported in two recent systematic reviews [1, 11 ].”
BackgroundResultErnst, A., Anantham, D., Eberhardt, R., Krasnik, M., & Herth, F. J. F. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e3181753b5e · Cited by 322 · cited 1×
“Moreover, it cannot be repeatedly operated on the same patient [5,6].”
BackgroundThe current role of mediastinoscopy in the evaluation of thoracic disease
Hammoud, Z. T., Anderson, R. C., Meyers, B. F., Guthrie, T. J., Roper, C. L., Cooper, J. D., & Patterson, G. A. (1999) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70059-0 · Cited by 319 · cited 1×
“Unfortunately it does have a 2% risk of morbidity and 0.08% mortality [1, 9 ,10].”
BackgroundInfluentialRintoul, R. C., Skwarski, K. M., Murchison, J. T., Wallace, W. A., Walker, W. S., & Penman, I. D. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00095404 · Cited by 309 · cited 1×
“Real-time endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) is a new technique that combines endoscopic visualization with high frequency ultrasound imaging, which is used to obtain cytological and histological samples of lesions adjacent to the tracheobronchial tree [2-4].”
MethodNakajima, T., Yasufuku, K., Suzuki, M., Hiroshima, K., Kubo, R., Mohammed, S., Miyagi, Y., Matsukuma, S., Sekine, Y., & Fujisawa, T. (2007) · Chest · doi:10.1378/chest.07-0095 · Cited by 198 · cited 1×
“We detected EGFR mutation on the cytological level, which was different from what Nakajima reported on the histological level in 2007 [16].”
Nakajima, T., Yasufuku, K., Kurosu, K., Takiguchi, Y., Fujiwara, T., Chiyo, M., Shibuya, K., Hiroshima, K., Nakatani, Y., & Yoshino, I. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.07.013 · Cited by 163 · cited 1×
“reported in 2009 [15], EBUS-TBNA should be added to conventional diagnostic modalities for patients with suspicious stage I sarcoidosis on chest roentgenogram.”
Background
Cited by
Methods for Staging Non-small Cell Lung Cancer
Silvestri, G. A., Gonzalez, A. V., Jantz, M. A., Margolis, M. L., Gould, M. K., Tanoue, L. T., Harris, L. J., & Detterbeck, F. C. (2013) · Chest · doi:10.1378/chest.12-2355 · Cited by 1,483
Jain, D., Allen, T. C., Aisner, D. L., Beasley, M. B., Cagle, P. T., Capelozzi, V. L., Hariri, L. P., Lantuejoul, S., Miller, R., Mino-Kenudson, M., et al. (2018) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2017-0114-sa · Cited by 183
Dong, X., Qiu, X., Liu, Q., & Jia, J. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2013.05.016 · Cited by 120
Bugalho, A., Ferreira, D., Eberhardt, R., Dias, S. S., Videira, P. A., Herth, F. J. F., & Carreiro, L. (2013) · BMC Cancer · doi:10.1186/1471-2407-13-130 · Cited by 58
Cömert, S. Ş., Parmaksız, E. T., Çağlayan, B., Salepçi, B. M., Kıral, N., Fidan, A., & Saraç, G. (2012) · Annals of Thoracic Medicine · doi:10.4103/1817-1737.102171 · Cited by 42
Endoscopic ultrasound in the diagnosis and staging of lung cancer
Colella, S., Vilmann, P., Konge, L., & Clementsen, P. F. (2014) · Endoscopic Ultrasound · doi:10.4103/2303-9027.144510 · Cited by 38
“A part from the studies already mentioned when abnormal radiological mediastinal LNs are considered, the sensitivity of EBUS — ranges from 85% to 97%.[34-45]”
BackgroundMurthi, M., Donna, E., Arias, S., Villamizar, N. R., Nguyen, D. M., Holt, G. E., & Mirsaeidi, M. S. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00118 · Cited by 34
Choi, S. M., Lee, A.-R., Choe, J., Nam, S. J., Chung, D. H., Lee, J., Lee, C., Lee, S., Yim, J., Yoo, C., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.06.086 · Cited by 33
Jin, F., Li, Q., Li, S., Wang, H., Bai, C., Zeng, Y., Zhou, R., Cai, Z., Chen, L., Feng, J., et al. (2019) · Respiration · doi:10.1159/000497213 · Cited by 32
Endobronchial ultrasound transbronchial needle aspiration in older people
Okachi, S., Imai, N., Imaizumi, K., Hase, T., Shindo, Y., Sakamoto, K., Aso, H., Wakahara, K., Hashimoto, I., Ito, S., et al. (2013) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/ggi.12043 · Cited by 26
The Role of Endobronchial Ultrasound in Lung Cancer Diagnosis and Staging: A Comprehensive Review
Kokkonouzis, I., Strimpakos, A. S., Lampaditis, I., Tsimpoukis, S., & Syrigos, K. (2012) · Clinical Lung Cancer · doi:10.1016/j.cllc.2012.05.001 · Cited by 23
CHOUAID, C., Salaün, M., Gounant, V., Febvre, M., Vergnon, J., Jounieaux, V., Fournier, C., Lachkar, S., Hermant, C., Raspaud, C., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0208992 · Cited by 22
Real-time prediction of mediastinal lymph node malignancy by endobronchial ultrasound
Shafiek, H., Fiorentino, F., Peralta, A. D., Serra, E., Esteban, B., Martínez, R., Noguera, M. A., Moyano, P., Sala, E., Sauleda, J., et al. (2014) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2014.05.003 · Cited by 21
Mehta, H. J., Tanner, N. T., Silvestri, G. A., Simkovich, S. M., Shamblin, C. J., Shaftman, S. R., Nietert, P. J., & Yang, J. Z. (2014) · Cancer Cytopathology · doi:10.1002/cncy.21482 · Cited by 20
Shafiek, H., Fiorentino, F., Peralta, A. D., Serra, E., Esteban, B., Martínez, R., Noguera, M. A., Moyano, P., Sala, E., Sauleda, J., et al. (2014) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2013.12.002 · Cited by 20
EBUS-TBNA for the Diagnosis of Lymphoma. Still an Achilles Heel
Bandyopadhyay, D., Panchabhai, T. S., & Mehta, A. C. (2015) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201507-403ed · Cited by 19
Qiu, T., Zhu, H., Cai, M., Han, Q., Shi, J., & Wang, K. (2015) · Acta Cytologica · doi:10.1159/000376545 · Cited by 18
Schneiter, D., Franzen, D., Weder, W., & Kohler, M. (2016) · Endoscopic Ultrasound · doi:10.4103/2303-9027.190925 · Cited by 18
“[15] In contrast, only few selected criteria influencing the diagnostic accuracy of EBUS-TBNA have been investigated that led to conflicting results.[2,16]”
BackgroundMethodResultInfluentialSantos, J. S., Andreo, F., Castellà, E., Llatjós, M., Castro, P. L. D., Astudillo, J., García‐Luján, R., Serra, P., & Monsó, E. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.10.006 · Cited by 18
Whitson, B. A., Groth, S. S., Odell, D. D., Briones, E. P., Maddaus, M. A., D’Cunha, J., & Andrade, R. S. (2012) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2012.09.057 · Cited by 17
Çetınkaya, E., Özgül, M. A., Tutar, N., Özgül, G., Çam, E., & Bilaçeroğlu, S. (2013) · Annals of Thoracic and Cardiovascular Surgery · doi:10.5761/atcs.oa.12.02072 · Cited by 17
“5 (21–89) Lymph node characteristics Number lymph nodes, n 123 Node size, mm* 16 (6.”
BackgroundGupta, S., Jain, Y. K., Agrawal, R., Mishra, J., & Singh, P. (2015) · Journal of Cytology · doi:10.4103/0970-9371.171226 · Cited by 17
“A sensitivity of 95% and specificity of 100% was reported by Ye et al.[9] Al sharif et al.”
BackgroundEvaluation of cytology in lung cancer diagnosis based on EBUS-TBNA
Wu, C., Dong, Z., Li, H., & Jiang, H. (2017) · Journal of Cytology · doi:10.4103/0970-9371.203567 · Cited by 16
Precision diagnostics: integration of tissue pathology and genomics in cancer
Sharma, S., George, P. M., & Waddell, N. (2021) · Pathology · doi:10.1016/j.pathol.2021.08.003 · Cited by 19
Agrawal, S. P., Ish, P., Goel, A. D., Gupta, N., Chakrabarti, S., Bhattacharya, D., Sen, M. K., & Suri, J. C. (2018) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2018.928 · Cited by 14
“The broad application of Endobronchial Ultrasound (EBUS) has opened new opportunities for ultrasound guided lymph node sampling [2].”
BackgroundDoss, A., Howarth, T. P., Ng, L., Doss, S. A., & Heraganahally, S. S. (2023) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13569 · Cited by 11
“14 17 Moreover, there are substantial challenges with access to investigative modalities such as EBUS for Indigenous patients, as the majority of Indigenous people reside in remote and rural localities.”
BackgroundLearning curve of conventional transbronchial needle aspiration
Tutar, N., Büyükoğlan, H., Yılmaz, İ., Kanbay, A., Önal, Ö., Bilgin, M., Canöz, Ö., Demir, R., Oymak, F. S., Gülmez, İ., et al. (2013) · The Clinical Respiratory Journal · doi:10.1111/crj.12041 · Cited by 11
“The recently developed EBUS-TBNA procedure enables direct and real-time aspiration of mediastinal and hilar lymph nodes (23).”
MethodMassive mediastinal cryptococcosis in a young immunocompetent patient
Okachi, S., Wakahara, K., Kato, D., Umeyama, T., Yagi, T., & Hasegawa, Y. (2015) · Respirology Case Reports · doi:10.1002/rcr2.111 · Cited by 10
“Although conventional TBNA might be also diagnostic, we routinely perform EBUS-TBNA for diagnosis of mediastinal and hilar lymphadenopathy because the usefulness and safety of EBUS-TBNA have been established [5].”
MethodTedde, M. L., Figueiredo, V. R., Terra, R. M., Minamoto, H., & Jatene, F. B. (2012) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132012000100006 · Cited by 10
Luo, G., Cai, P., He, J., Li, X. H., Li, Y., Shan, H., Zhang, R., Gao, X.-Y., Lao, X., & Xu, G.-L. (2013) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-013-9657-x · Cited by 10
“Our diagnostic accuracy was consistent with the results in previous studies [2, 3, 11, 12].”
ResultLung cancer screening in China: early-stage lung cancer and minimally invasive surgery 3.0
Zheng, D., & Chen, H. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.05.206 · Cited by 9
“This technique is more minimally invasive and safer, with a diagnostic accuracy of 97%, and can be a replacement for most mediastinoscopic procedures (9).”
BackgroundSelf-citationUlain, N., Ali, A., Khan, M., Ullah, Z., Shaheen, L., Shareef, N., Yasir, M., & Mustafa, T. (2022) · PLoS ONE · doi:10.1371/journal.pone.0276064 · Cited by 8
“This technique has been shown to increase the confidence level of cytopathologists in the diagnosis of lymphadenopathy [33, 34] and therefore it is recommended for routine cytomorphological analysis instead of cell smears.”
MethodBoonsarngsuk, V., Pongtippan, A., & Juthakarn, S. (2013) · Lung · doi:10.1007/s00408-013-9480-6 · Cited by 8
“Apparently, location and size of the lesion [8] and the availability of rapid on-site cytology evaluation (ROSE) [9] do not affect its performance.”
BackgroundKużdżał, J., & Szlubowski, A. (2012) · Thoracic surgery clinics/Thorac. surg. clin. · doi:10.1016/j.thorsurg.2011.12.006 · Cited by 8
Jeebun, V., & Harrison, R. N. (2017) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.05.18 · Cited by 8
“Additionally, a number of studies have utilized ROSE (32,33,35,38,39-41,42,44,48,50), which was not available at our centre, other studies which have contributed to the meta-analysis combined both EBUS and endoscopic ultrasonography (EUS).”
BackgroundResultInfluentialTunç, M., Sazak, H., Öztürk, A., Yılmaz, A., & Alagöz, A. (2023) · BMC Anesthesiology · doi:10.1186/s12871-023-02241-7 · Cited by 7
“Accurate staging is crucial in elderly patients in determining prognosis and treatment [2].”
BackgroundEndobronchial Ultrasound in Suspected Non-Malignant Mediastinal Lymphadenopathy
Eickhoff, L., Golpon, H. A., Zardo, P., Suhling, H., Welte, T., Jonigk, D. D., Gottlieb, J., & Fuehner, T. (2018) · Pneumologie · doi:10.1055/a-0583-0265 · Cited by 7
“Endobronchial ultrasound is a minimally invasive technique to obtain tissue via ultrasonic bronchoscope to visualise and perform a real-time transbronchial needle aspiration under direct endobronchial ultrasonographic guidance [1, 2].”
Accidental fracture of EBUS-TBNA needle during sampling of an enlarged mediastinal lymph node
Tariq, S. M. (2016) · Oxford Medical Case Reports · doi:10.1093/omcr/omw015 · Cited by 6
Zhang, W. C., Chen, W., Zhou, J., Lerner, A. D., Ni, L., Shen, J., Yan, T. L., Zhou, M., Shi, G. C., & Xiang, Y. (2017) · Respiration · doi:10.1159/000462978 · Cited by 6
Ojha, P., Madan, R., & Bharadwaj, R. (2019) · Archives of Medicine and Health Sciences · doi:10.4103/amhs.amhs_135_18 · Cited by 6
“in their study stationed the mediastinal lymph nodes according to the puncture site as the upper paratracheal (2R, 2 L), subcarinal (7), the lower paratracheal and hilar (4R, 4 L, 10R, and 10 L), the right paraesophageal (8R), and the interlobar station (11 L, 11R).[29] The sensitivity was 95.”
BackgroundLuthra, K., & Singh, J. (2021) · Indian Journal of Cancer · doi:10.4103/ijc.ijc_687_19 · Cited by 5
Magdy, O., Dayem, A. M. A., Maraghy, A. A. E., Ali, M., & Hafez, F. S. (2024) · Egyptian Journal of Bronchology · doi:10.1186/s43168-024-00322-w · Cited by 5
“Ye et al. [23] reported a sensitivity of 95% and a specificity of 100%.”
BackgroundEknewir, S., John, T.-J., Bennji, S. M., & Koegelenberg, C. F. N. (2022) · African Journal of Thoracic and Critical Care Medicine · doi:10.7196/ajtccm.2022.v28i1.156 · Cited by 5
“The diagnostic sensitivity of cervical mediastinoscopy has been reported to be as low as 78 - 81% in two systematic reviews, showing that this modality that has traditionally been the ‘gold standard’ for diagnosing mediastinal lymphadenopathy, is in fact inferior to EBUS-TBNA in sensitivity and morbidity.[2] Our prese…”
BackgroundMethodResultInfluentialZaidi, S. N., & Raddaoui, E. M. S. (2015) · CytoJournal · doi:10.4103/1742-6413.165947 · Cited by 5
Mediastinal lymphadenopathy in malignancy: metastatic or granulomatous?
Subramanian, S., Sandeepa, H., Chaudhari, P., Kate, A. H., Kumar, S., Shah, P. R., & Chhajed, P. N. (2014) · PubMed · Cited by 4
Helalah, L. A., Madkour, A. M., Elfattah, N. M. A., Mohammed, R. M., Farghaly, A. A. H., Fawzy, R. A., & Elasser, A. M. A. (2019) · Egyptian Journal of Bronchology · doi:10.4103/ejb.ejb_57_19 · Cited by 4
Mediastinal lymph node staging for lung cancer
Sawabata, N. (2019) · Mediastinum · doi:10.21037/med.2019.07.04 · Cited by 4
Durmuş, Ş. E. (2021) · Diagnostic Cytopathology · doi:10.1002/dc.24898 · Cited by 3
“It is recommended by current guidelines as the first-line approach for mediastinal lymph node staging of lung cancer,(3,4) for which it has high sensitivity (88%–93%), specificity (100%), and diagnostic accuracy (98%).(4,5) Cytology is a useful method in the diagnosis of lesions of the respiratory tract.”
Embaby, D. A. E. S. E., Abdullah, F. A. A., Korraa, E., Shalaby, H. M., Ibrahim, E. A.-S., Emam, W., & Maher, R. (2024) · Egyptian Journal of Bronchology · doi:10.1186/s43168-024-00328-4 · Cited by 3
“However, contrasts most similar studies where the range is usually a bit narrower, as seen with Ye et al. [35] Where the range was two to five passes .”
ResultRaddaoui, E. M. S., Alhamad, E. H., Zaidi, S. N., Alhabeeb, F., & Arafah, M. (2014) · CytoJournal · doi:10.4103/1742-6413.137760 · Cited by 3
Verma, V., Khan, A., Rao, R. N., Nath, A., & Hashim, Z. (2021) · Journal of Cytology · doi:10.4103/joc.joc_55_21 · Cited by 2
“[6] Hence, it allows precise sampling of lesions adjacent to the tracheobronchial tree, including mediastinal and hilar lymph nodes.”
Traveling with ROSE in EBUS-TBNA – Experience from a Tertiary Care Hospital in South India
Vasugi, G. A., Mathivanan, K. M., Rajendiran, S., Sundaram, S., & Ayub, I. I. (2021) · Journal of Cytology · doi:10.4103/joc.joc_60_21 · Cited by 3
Negative Predictive Value of Endobronchial Ultrasound–guided Transbronchial Needle Aspiration
Bellinger, C., Ruiz, J., & Dotson, T. L. (2016) · Clinical Pulmonary Medicine · doi:10.1097/cpm.0000000000000147 · Cited by 1
Chest wall resections for non-small cell lung cancer: a literature review
Huang, L., Li, F., Neudecker, J., Elsner, A., Strauchmann, J., Dziodzio, T., Zhou, H., & Rueckert, J.-C. (2024) · Journal of Thoracic Disease · doi:10.21037/jtd-23-774 · Cited by 1
Val‐Bernal, J. F., Martino, M., Contreras, E. Y., Romay, F., Sánchez‐Ares, M., & Abdulkader, I. (2018) · Turkish Journal of Pathology · doi:10.5146/tjpath.2018.01437 · Cited by 1
“2, 2019; Page 92-101 Furthermore, the method cannot be repeatedly conducted on the same patient (12-14).”
Rhee, C. K. (2013) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2013.28.6.652
Benign Mediastinal/Hiler Lenfadenopatilerde Etyoloji
Erbay, M., Özlü, T., Bülbül, Y., Öztuna, F., Özsu, S., & Tekinbaş, C. (2019) · Uludağ Üniversitesi Tıp Fakültesi Dergisi · doi:10.32708/uutfd.594753
Gul, S. K., Niksarlıoğlu, E. Y. Ö., & Yeter, A. (2021) · Acta Medica · doi:10.32552/2021.actamedica.557
“However, in other studies, there was no significant correlation between diagnostic accuracy and the number of passes [24, 25].”
Successful Diagnosis of Epithelial Thymic Cancer Case Using EBUS-TBNA
Issa, T., Sharma, R., Aboaid, S., Polineni, R. D., & Aboeed, A. (2022) · Journal of Investigative Medicine High Impact Case Reports · doi:10.1177/23247096221090791
Krüger, M., & Ivanyi, P. (2019) · Springer Reference Medizin · doi:10.1007/978-3-642-54676-1_382-1
Spalgais, S., Kumar, R., Mrigpuri, P., & Vikrant, F. (2022) · The Indian Journal of Chest Diseases and Allied Sciences · doi:10.5005/ijcdas-62-1-19
Yield and Complications of Endobronchial Ultrasound Using the Expect Endobronchial Ultrasound Needle
Ghazal, F., Hanna, S., Costanian, C., Nuguru, S., & Diab, K. J. (2024) · Southwest Journal of Pulmonary Critical Care & Sleep · doi:10.13175/swjpccs020-23
Intraoperative Consultation in Frozen Section of Intrathoracic Lesions
Marchevsky, A. M., Lai, J., & McKenna, R. J. (2015) · Elsevier eBooks · doi:10.1016/b978-1-4557-4823-5.00009-3
Remimazolam in elderly patients undergoing EBUS-TBNA: protocol for a randomized clinical trial
Liu, Y., Chen, Y., Ma, L., Zhang, F., Yang, M., & He, L. (2025) · International Journal of Surgery Protocols · doi:10.1097/sp9.0000000000000058
“Lung cancer predominantly affects individuals over the age of 65, with statistics indicating that majority of cases occur in this age group [ 10 , 11 ] .”
Bennji, S. M., Jayakrishnan, B., Al-Hashami, Z. S., Ravi, P. R., Alhabsi, A., Qarshoubi, I. A., & Koegelenberg, C. F. N. (2026) · Annals of Thoracic Medicine · doi:10.4103/atm.atm_374_25
“[4] Similarly, the evaluation of hilar, interlobar, and lobar lymph nodes with N1 and N3 status with EBUS‑TBNA in primary lung cancer showed the overall diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predictive value of 95.7, 100, 97.3, 93.2, and 100%,…”
InfluentialAbdulnaby, N. K., Kamel, K. M., Ashur, W. M., Selim, S., El-Naiem, A., & Farrag, S. M. (2026) · Egyptian Journal of Bronchology · doi:10.1186/s43168-026-00563-x
Molecular Analysis of EBUS-TBNA Samples for Nodal Staging in Non-Small Cell Lung Cancer
Ehab, A., Benabdallah, N., & Darwiche, K. (2026) · Cancers · doi:10.3390/cancers18111797
“The size of metastatic lymph nodes may also influence the reliability of molecular analyses performed on EBUS-TBNA-derived specimens, although the impact of lymph node size remains controversial [117].”
Influential
Metadata
- Authors
- Ye, T., Hu, H., Luo, X., & Chen, H.
- Affiliations
- Shanghai Medical College of Fudan University (CN)
- Corresponding author
- Chen, Haiquan
- Venue
- BMC Cancer
- Published
- 2011-03-21
- Volume
- 11
- Issue
- 1
- Pages
- 100-100
- ISSN
- 1471-2407 (ISSN-L)
- PMC
- PMC3076261
- OpenAlex
- W2129153972
- Semantic Scholar
- 4321de094e11a957519cb1c41be0fcff4106520f
- Cited by
- 67
- References
- 17
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 4 · 2023: 2 · 2022: 4 · 2021: 6 · 2020: 1 · 2019: 7 · 2018: 4 · 2017: 4 · 2016: 3 · 2015: 7 · 2014: 6 · 2013: 9 · 2012: 5
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMC Cancer (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Pathology and Forensic Medicine › Lymphadenopathy Diagnosis and Analysis
- Health Sciences › Medicine › Oncology › Cancer Diagnosis and Treatment
- Keywords
- endobronchial ultrasound-guided transbronchial needle aspiration, mediastinal lymphadenopathy, hilar lymphadenopathy, mediastinoscopy, diagnostic accuracy, lung cancer diagnosis, lymph node biopsy, EGFR mutation, cytology, histology
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biopsy, Needle, Bronchi, Feasibility Studies, Female, Follow-Up Studies, Humans, Lymph Nodes, Lymphatic Diseases, Male, Mediastinum, Middle Aged, Predictive Value of Tests, Prognosis, Sensitivity and Specificity, Ultrasonography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.