Application of serum SELDI proteomic patterns in diagnosis of lung cancer
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: Currently, no satisfactory biomarkers are available to screen for lung cancer. Surface-Enhanced Laser Desorption/ionization Time-of- Flight Mass Spectrometry ProteinChip system (SELDI-TOF-MS) is one of the currently used techniques to identify biomarkers for cancers. The aim of this study is to explore the application of serum SELDI proteomic patterns to distinguish lung cancer patients from healthy individuals. Methods: A total of 208 serum samples, including 158 lung cancer patients and 50 healthy individuals, were randomly divided into a training set (including 11 sera from patients with stages I/II lung cancer, 63 from patients with stages III/IV lung cancer and 20 from healthy controls) and a blinded test set (including 43 sera from patients with stages I/II lung cancer, 41 from patients with stages III/IV lung cancer and 30 from healthy controls). All samples were analyzed by SELDI technology. The spectra were generated on weak cation exchange (WCX2) chips, and protein peaks clustering and classification analyses were made using Ciphergen Biomarker Wizard and Biomarker Pattern software, respectively. We additionally determined Cyfra21-1 and NSE in the 208 serum samples included in this study using an electrochemiluminescent immunoassay. Results: Five protein peaks at 11493, 6429, 8245, 5335 and 2538 Da were automatically chosen as a biomarker pattern in the training set. When the SELDI marker pattern was tested with the blinded test set, it yielded a sensitivity of 86.9%, a specificity of 80.0% and a positive predictive value of 92.4%. The sensitivities provided by Cyfra21-1 and NSE used individually or in combination were significantly lower than that of the SELDI marker pattern (P < 0.005 or 0.05, respectively). Based on the results of the test set, we found that the SELDI marker pattern showed a sensitivity of 91.4% in the detection of non-small cell lung cancers (NSCLC), which was significantly higher than that in the detection of small cell lung cancers (P < 0.05); The pattern also had a sensitivity of 79.1% in the detection of lung cancers in stages I/II. Conclusion: These results suggest that serum SELDI protein profiling can distinguish lung cancer patients, especially NSCLC patients, from normal subjects with relatively high sensitivity and specificity, and the SELDI-TOF-MS is a potential tool for the screening of lung cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Multidisciplinary Management of Lung Cancer
Spira, A., & Ettinger, D. S. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035536 · Cited by 922 · cited 1×
“Background Lung cancer is, at present, the most common malignancy in the world and its overall 5-year survival rate is only 14% [1].”
BackgroundLung Cancer Screening with CT: Mayo Clinic Experience
Swensen, S. J., Jett, J. R., Hartman, T. E., Midthun, D. E., Sloan, J. A., Sykes, A.-M., Aughenbaugh, G. L., & Clemens, M. A. (2003) · Radiology · doi:10.1148/radiol.2263020036 · Cited by 665 · cited 1×
“All these methods, however, lack adequate sensitivity and/or specificity [ 3-6 ].”
BackgroundNew desorption strategies for the mass spectrometric analysis of macromolecules
Hutchens, T. W., & Yip, T. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070703 · Cited by 621 · cited 1×
“Surface-Enhanced Laser Desorption /ionization Time-of-Flight Mass Spectrometry (SELDI-TOF-MS), an innovative proteomic technology introduced by Hutchens and Yip [7], has overcome many of the limitations of two-dimensional electrophoresis and MatrixAssisted Laser Desorption/ionization Time-of-Flight Mass Spectrometry (…”
Adam, B.-L., Qu, Y., Davis, J. W., Ward, M. D., Clements, M. A., Cazares, L. H., Semmes, O. J., Schellhammer, P. F., Yasui, Y., Feng, Z., et al. (2002) · PubMed · Cited by 612
Localization of Bronchial Intraepithelial Neoplastic Lesions by Fluorescence Bronchoscopy
Lam, S., Kennedy, T., Unger, M., Miller, Y. E., Gelmont, D., Rusch, V., Gipe, B., Howard, D., LeRiche, J. C., Coldman, A., et al. (1998) · Chest · doi:10.1378/chest.113.3.696 · Cited by 571 · cited 1×
“All these methods, however, lack adequate sensitivity and/or specificity [3-6].”
BackgroundVlahou, A., Schellhammer, P. F., Mendrinos, S., Patel, K., Kondylis, F. I., Gong, L., Nasim, S., & Wright Jr., G. L. (2001) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64100-4 · Cited by 409
Rosty, C., Christa, L., Kuzdzal, S. A., Baldwin, W. M., ZAHURAK, M. L., Carnot, F., Chan, D. W., Canto, M. I., Lillemoe, K. D., Cameron, J. L., et al. (2002) · PubMed · Cited by 292
Koopmann, J., Zhang, Z., White, N., Rosenzweig, J., Fedarko, N., Jagannath, S., Canto, M. I., Yeo, C. J., Chan, D. W., & Goggins, M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-1167-3 · Cited by 282 · cited 1×
“It can detect multiple protein changes simultaneously with high sensitivity and specificity [10,11].”
BackgroundKulpa, J., Wójcik, E., Reinfuss, M., & Kołodziejski, L. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.1931 · Cited by 242 · cited 1×
“All these methods, however, lack adequate sensitivity and/or specificity [ 3-6 ].”
Background
Cited by
Human body fluid proteome analysis
Hu, S., Loo, J. A., & Wong, D. T. (2006) · PROTEOMICS · doi:10.1002/pmic.200600284 · Cited by 533
Contribution of oncoproteomics to cancer biomarker discovery
Cho, W. C. (2007) · Molecular Cancer · doi:10.1186/1476-4598-6-25 · Cited by 268
Exhaled biomarkers in lung cancer
Horváth, I., Lázár, Z., Gyulai, N., Kollai, M., & Losonczy, G. (2009) · European Respiratory Journal · doi:10.1183/09031936.00142508 · Cited by 268
Label‐free detection techniques for protein microarrays: Prospects, merits and challenges
Ray, S., Mehta, G., & Srivastava, S. (2010) · PROTEOMICS · doi:10.1002/pmic.200900458 · Cited by 224
“These technologies include SPR-MS [106] , backscattering interferometry [66, 107] , brewster angle straddle interferometry [108] , UV fluorometry [109, 110] , SELDI-TOF-MS [111] [112] [113] , taggedinternal standard assay [114] and spectral-domain optical coherence phase microscopy [115] .”
MethodSample preparation for serum/plasma profiling and biomarker identification by mass spectrometry
Luque-Garcia, J. L., & Neubert, T. A. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.054 · Cited by 212
Heo, S., Lee, S., Ryoo, H., Park, J., & Cho, J. (2007) · PROTEOMICS · doi:10.1002/pmic.200700433 · Cited by 166
“2-DE coupled with MALDI-TOF [4, 5, 7], Western blot arrays [19] and SELDI [1, 21], have also been developed to identify cancer biomarkers.”
Method
Metadata
- Authors
- Yang, S.-Y., Xiao, X.-Y., Zhang, W.-G., Zhang, L.-J., Zhang, W., Zhou, B., Chen, G., & He, D.-C.
- Venue
- BMC Cancer
- Published
- 2005-07-20
- Volume
- 5
- Issue
- 1
- Pages
- 83-83
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W1536912963
- Cited by
- 161
- References
- 12
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.