CoChat

Interstitial fluid pressure, vascularity and metastasis in ectopic, orthotopic and spontaneous tumours

Open access
Lunt, Sarah Jane, Kalliomaki, Tuula MK, Brown, Allison, Yang, Victor X, Milosevic, Michael, Hill, Richard P · 2008 · BMC Cancer
Cited by 106

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: High tumour interstitial fluid pressure (IFP) has been adversely linked to poor drug uptake in patients, and to treatment response following radiotherapy in cervix cancer patients. In this study we measured IFP values in a selection of murine and xenograft models, spontaneously arising or transplanted either intramuscularly (i/m) or orthotopically and analysed their relationship to tumour vascularity and metastatic spread. Methods: KHT-C murine fibrosarcoma, ME180 and SiHa human cervix carcinoma were grown either intramuscularly (i/m), sub-cutaneously (s/c) or orthotopically. Polyoma middle-T (MMTV-PyMT) transgenic spontaneous mammary tumours were studied either as spontaneous tumours or following orthotopic or i/m transplantation. IFP was measured in all tumours using the wick-in-needle method. Spontaneous metastasis formation in the lungs or lymph nodes was assessed in all models. An immunohistochemical analysis of tumour hypoxia, vascular density, lymphatic vascular density and proliferation was carried out in ME180 tumours grown both i/m and orthotopically. Blood flow was also assessed in the ME180 model using high-frequency micro-ultrasound functional imaging. Results: Tumour IFP was heterogeneous in all the models irrespective of growth site: KHT-C i/m: 2–42 mmHg, s/c: 1–14 mmHg, ME180: i/m 5–68 mmHg, cervix 4–21 mmHg, SiHa: i/m 20–56 mmHg, cervix 2–26 mmHg, MMTV-PyMT: i/m: 13–45 mmHg, spontaneous 2–20 mmHg and transplanted 2–22 mmHg. Additionally, there was significant variation between individual tumours growing in the same mouse, and there was no correlation between donor and recipient tumour IFP values. Metastatic dissemination to the lungs or lymph nodes demonstrated no correlation with tumour IFP. Tumour hypoxia, proliferation, and lymphatic or blood vessel density also showed no relationship with tumour IFP. Speckle variance analysis of ultrasound images showed no differences in vascular perfusion between ME180 tumours grown i/m versus orthotopically despite differences in IFP. Conclusion: Our studies across a range of different tumour models showed substantial heterogeneity in tumour IFP, suggesting differences in the vascular development and interstitial fluid dynamics in the individual tumours. The results demonstrate a strong stochastic aspect to tumour IFP development, notably the variation apparent between different tumours within the same animal and the lack of correlation between donor and recipient tumours.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2407-8-2

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 106

Metadata

Authors
Lunt, S. J., Kalliomaki, T. M., Brown, A., Yang, V. X., Milosevic, M., & Hill, R. P.
Venue
BMC Cancer
Published
2008-01-07
Volume
8
Issue
1
Pages
2-2
ISSN
1471-2407 (ISSN-L)
OpenAlex
W1986986101
Cited by
106
References
8
FWCI
3.23
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interstitial fluid pressure, vascularity and metastasis in ectopic, orthotopic and spontaneous tumours. https://app.cochat.ai/papers/10.1186/1471-2407-8-2
The paper
Lunt, S. J., Kalliomaki, T. M., Brown, A., Yang, V. X., Milosevic, M., & Hill, R. P. (2008). Interstitial fluid pressure, vascularity and metastasis in ectopic, orthotopic and spontaneous tumours. BMC Cancer. https://doi.org/10.1186/1471-2407-8-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.