The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat
Open accessAbstract
BACKGROUND: Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D) motion analysis system. In addition, the inter-rater reliability was evaluated. METHODS: Twenty-five (17 women) non-injured participants (mean age 25.6 years, range 18-37) were included. Visual analysis of the medio-lateral knee motion, scored as knee-over-foot or knee-medial-to-foot by two raters, and 3-D kinematic data were collected simultaneously during a single-limb mini squat. Frontal plane 2-D peak tibial, thigh, and knee varus-valgus angles, and 3-D peak hip internal-external rotation, and knee varus-valgus angles were calculated. RESULTS: Ten subjects were scored as having a knee-medial-to-foot position and 15 subjects a knee-over-foot position assessed by visual inspection. In 2-D, the peak tibial angle (mean 89.0 (SE 0.7) vs mean 86.3 (SE 0.4) degrees, p = 0.001) and peak thigh angle (mean 77.4 (SE 1.0) vs mean 81.2 (SE 0.5) degrees, p = 0.001) with respect to the horizontal, indicated that the knee was more medially placed than the ankle and thigh, respectively. Thus, the knee was in more valgus (mean 11.6 (SE 1.5) vs 5.0 (SE 0.8) degrees, p < 0.001) in subjects with the knee-medial-to-foot than in those with a knee-over-foot position. In 3-D, the hip was more internally rotated in those with a knee-medial-to-foot than in those with a knee-over-foot position (mean 10.6 (SE 2.1) vs 4.8 (SE 1.8) degrees, p = 0.049), but there was no difference in knee valgus (mean 6.1 (SE 1.8) vs mean 5.0 (SE 1.2) degrees, p = 0.589). The kappa value and percent agreement, respectively, was >0.90 and 96 between raters. CONCLUSIONS: Medio-lateral motion of the knee can reliably be assessed during a single-leg mini-squat. The test is valid in 2-D, while the actual movement, in 3-D, is mainly exhibited as increased internal hip rotation. The single-limb mini squat is feasible and easy to administer in the clinical setting and in research to address lower extremity movement quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hewett, T. E., Myer, G. D., Ford, K. R., Heidt, R. S., Colosimo, A. J., McLean, S. G., van den Bogert, A. J., Paterno, M. V., & Succop, P. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504269591 · Cited by 3,577
Chmielewski, T. L., Hodges, M. J., Horodyski, M., Bishop, M. D., Conrad, B. P., & Tillman, S. M. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2457 · Cited by 113
Yamazaki, J., Muneta, T., Ju, Y. J., & Sekiya, I. (2010) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-009-0892-z · Cited by 88
Cited by
A Randomized, Controlled Trial of Total Knee Replacement
Skou, S. T., Roos, E. M., Laursen, M. B., Rathleff, M. S., Arendt-Nielsen, L., Simonsen, O., & Rasmussen, S. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1505467 · Cited by 816
Self-citationBarber-Westin, S. D., & Noyes, F. R. (2011) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.09.009 · Cited by 575
Weeks, B. K., Carty, C. P., & Horan, S. A. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-207 · Cited by 80
Lopes, T. J. A., Ferrari, D., Ioannidis, J., Simic, M., Mícolis de Azevedo, F., & Pappas, E. (2018) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2018.8006 · Cited by 48
Whatman, C., Hume, P., & Hing, W. (2013) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2012.06.001 · Cited by 44
Metadata
- Authors
- Ageberg, E., Bennell, K. L., Hunt, M. A., Simic, M., Roos, E. M., & Creaby, M. W.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2010-11-16
- Volume
- 11
- Issue
- 1
- Pages
- 265-265
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W2029282835
- Cited by
- 216
- References
- 3
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat. https://app.cochat.ai/papers/10.1186/1471-2474-11-265
- The paper
- Ageberg, E., Bennell, K. L., Hunt, M. A., Simic, M., Roos, E. M., & Creaby, M. W. (2010). Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat. BMC Musculoskeletal Disorders. https://doi.org/10.1186/1471-2474-11-265
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.