The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite®)
Open accessAbstract
BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at preferred and fast walking speeds using the GAITRite system. Measurements tested included walking speed, step length, stride length, base of support, step time, stride time, swing time, stance time, single and double support times, and toe in-toe out angle. RESULTS: Twenty-one healthy subjects participated in this study. The group consisted of 12 men and 9 women, with an average age of 34 years (range: 19-59 years). At preferred walking speed, all gait measurements had ICC's of 0.92 and higher, except base of support which had an ICC of 0.80. At fast walking speed all gait measurements had ICC's above 0.89 except base of support (ICC = 0.79), CONCLUSIONS: Spatial-temporal gait measurements demonstrate good to excellent test-retest reliability over a one-week time span.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Bilney, B., Morris, M., & Webster, K. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00053-x · Cited by 737
The validity and reliability of the GAITRite system's measurements: A preliminary evaluation
McDonough, A. L., Batavia, M., Chen, F. C., Kwon, S., & Ziai, J. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.19778 · Cited by 529
Reliability of Observational Kinematic Gait Analysis
Krebs, D. E., Edelstein, J. E., & Fishman, S. (1985) · Physical Therapy · doi:10.1093/ptj/65.7.1027 · Cited by 302
Evaluation of an instrumented walkway for measurement of the kinematic parameters of gait
Cutlip, R. G., Mancinelli, C., Huber, F., & DiPasquale, J. (2000) · Gait & Posture · doi:10.1016/s0966-6362(00)00062-x · Cited by 176
Gait consistency over a 7-day interval in people with parkinson's disease
Urquhart, D. M., Morris, M. E., & Iansek, R. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90175-2 · Cited by 31
Cited by
Wearable sensor-based objective assessment of motor symptoms in Parkinson’s disease
Ossig, C., Antonini, A., Buhmann, C., Classen, J., Csoti, I., Falkenburger, B., Schwarz, M., Winkler, J., & Storch, A. (2016) · Journal of Neural Transmission · doi:10.1007/s00702-015-1439-8 · Cited by 164
Metadata
- Authors
- van Uden, C. J., & Besser, M. P.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2004-05-17
- Volume
- 5
- Issue
- 1
- Pages
- 13-13
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W2139546539
- Cited by
- 307
- References
- 6
- FWCI
- 15.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite®). https://app.cochat.ai/papers/10.1186/1471-2474-5-13
- The paper
- van Uden, C. J., & Besser, M. P. (2004). Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite®). BMC Musculoskeletal Disorders. https://doi.org/10.1186/1471-2474-5-13
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.