The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty
Open accessAbstract
Background: Physical performance measures play an important role in the measurement of outcome in patients undergoing hip and knee arthroplasty. However, many of the commonly used measures lack information on their psychometric properties in this population. The purposes of this study were to examine the reliability and sensitivity to change of the six minute walk test (6MWT), timed up and go test (TUG), stair measure (ST), and a fast self-paced walk test (SPWT) in patients with hip or knee osteoarthritis (OA) who subsequently underwent total joint arthroplasty. Methods: A sample of convenience of 150 eligible patients, part of an ongoing, larger observational study, was selected. This included 69 subjects who had a diagnosis of hip OA and 81 diagnosed with knee OA with an overall mean age of 63.7 ± 10.7 years. Test-retest reliability, using Shrout and Fleiss Type 2,1 intraclass correlations (ICCs), was assessed preoperatively in a sub-sample of 21 patients at 3 time points during the waiting period prior to surgery. Error associated with the measures' scores and the minimal detectable change at the 90% confidence level was determined. A construct validation process was applied to evaluate the measures' abilities to detect deterioration and improvement at two different time points post-operatively. The standardized response mean (SRM) was used to quantify change for all measures for the two change intervals. Bootstrapping was used to estimate the 95% confidence intervals (CI) for the SRMs. Results: The ICCs (95% CI) were as follows: 6MWT 0.94 (0.88,0.98), TUG 0.75 (0.51, 0.89), ST 0.90 (0.79, 0.96), and the SPWT 0.91 (0.81, 0.97). Standardized response means varied from .79 to 1.98, being greatest for the ST and 6MWT over the studied time intervals. Conclusions: The test-retest estimates of the 6MWT, ST, and the SPWT met the requisite standards for making decisions at the individual patient level. All measures were responsive to detecting deterioration and improvement in the early postoperative period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
A leisurely look at the bootstrap, the jackknife, and cross-validation
Efron, B., & Gong, G. (1983) · The American Statistician · doi:10.1080/00031305.1983.10483087 · Cited by 3,229
Osteoarthritis: New Insights. Part 1: The Disease and Its Risk Factors
Felson, D. T., Lawrence, R. C., Dieppe, P. A., Hirsch, R., Helmick, C. G., Jordan, J. M., Kington, R. S., Lane, N. E., Nevitt, M. C., Zhang, Y., et al. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00016 · Cited by 2,519
Measuring change over time: Assessing the usefulness of evaluative instruments
Guyatt, G., Walter, S., & Norman, G. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90069-5 · Cited by 1,880
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
URIST, M. R. (1967) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196709000-00023 · Cited by 1,590
Guccione, A. A., Felson, D. T., Anderson, J. J., Anthony, J. M., Zhang, Y., Wilson, P. W., Kelly-Hayes, M., Wolf, P. A., Kreger, B. E., & Kannel, W. B. (1994) · American Journal of Public Health · doi:10.2105/ajph.84.3.351 · Cited by 1,584
A methodological framework for assessing health indices
Kirshner, B., & Guyatt, G. (1985) · Journal of Chronic Diseases · doi:10.1016/0021-9681(85)90005-0 · Cited by 1,538
Felson, D. T., & McAlindon, T. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-136-1-200201010-00019 · Cited by 1,122
Redelmeier, D. A., Bayoumi, A. M., Goldstein, R. S., & Guyatt, G. H. (1997) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.155.4.9105067 · Cited by 1,029
Cited by
Dobson, F., Hinman, R. S., Roos, E. M., Abbott, J. H., Stratford, P., Davis, A. M., Buchbinder, R., Snyder-Mackler, L., Henrotin, Y., Thumboo, J., et al. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.05.002 · Cited by 908
Self-citationMizner, R. L., Petterson, S. C., Clements, K. E., Zeni, J. A., Irrgang, J. J., & Snyder-Mackler, L. (2011) · The Journal of Arthroplasty · doi:10.1016/j.arth.2010.06.004 · Cited by 349
Rolfson, O., Bohm, E., Franklin, P., Lyman, S., Denissen, G., Dawson, J., Dunn, J., Eresian Chenok, K., Dunbar, M., Overgaard, S., et al. (2016) · Acta Orthopaedica · doi:10.1080/17453674.2016.1181816 · Cited by 323
Intramuscular adipose tissue, sarcopenia, and mobility function in older individuals
Marcus, R. L., Addison, O., Dibble, L. E., Foreman, K. B., Morrell, G., & LaStayo, P. (2012) · Journal of Aging Research · doi:10.1155/2012/629637 · Cited by 296
Dobson, F., Hinman, R. S., Hall, M., Terwee, C. B., Roos, E. M., & Bennell, K. L. (2012) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.08.015 · Cited by 278
Metadata
- Authors
- Kennedy, D. M., Stratford, P. W., Wessel, J., Gollish, J. D., & Penney, D.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2005-01-28
- Volume
- 6
- Issue
- 1
- Pages
- 3-3
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W1587236774
- Cited by
- 512
- References
- 39
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty. https://app.cochat.ai/papers/10.1186/1471-2474-6-3
- The paper
- Kennedy, D. M., Stratford, P. W., Wessel, J., Gollish, J. D., & Penney, D. (2005). Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty. BMC Musculoskeletal Disorders. https://doi.org/10.1186/1471-2474-6-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.