A simple viability analysis for unicellular cyanobacteria using a new autofluorescence assay, automated microscopy, and ImageJ
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Currently established methods to identify viable and non-viable cells of cyanobacteria are either time-consuming (eg. plating) or preparation-intensive (eg. fluorescent staining). In this paper we present a new and fast viability assay for unicellular cyanobacteria, which uses red chlorophyll fluorescence and an unspecific green autofluorescence for the differentiation of viable and non-viable cells without the need of sample preparation. RESULTS: The viability assay for unicellular cyanobacteria using red and green autofluorescence was established and validated for the model organism Synechocystis sp. PCC 6803. Both autofluorescence signals could be observed simultaneously allowing a direct classification of viable and non-viable cells. The results were confirmed by plating/colony count, absorption spectra and chlorophyll measurements. The use of an automated fluorescence microscope and a novel ImageJ based image analysis plugin allow a semi-automated analysis. CONCLUSIONS: The new method simplifies the process of viability analysis and allows a quick and accurate analysis. Furthermore results indicate that a combination of the new assay with absorption spectra or chlorophyll concentration measurements allows the estimation of the vitality of cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
“Both OD750 and the height of the peaks of phycocyanin, chlorophyll and carotenoids in the absorption spectra decreased with the loss of viability [35].”
BackgroundHigh-throughput cultivation and screening platform for unicellular phototrophs
Tillich, U. M., Wolter, N., Schulze, K., Kramer, D., Brödel, O., & Frohme, M. (2014) · BMC Microbiology · doi:10.1186/s12866-014-0239-x · Cited by 31
Self-citationSrivastava, V., Amanna, R., Rowden, S. J. L., Sengupta, S., Madhu, S., Howe, C. J., & Wangikar, P. P. (2021) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2020.11.012 · Cited by 29
“The fixed cells were mounted on the slide and 174 observed under a fluorescence microscope (23).”
BackgroundMicroalgae Microneedle Supplies Oxygen for Antiphotoaging Treatment
Wang, Z., Kwong, C. H. T., Zhao, H., Ding, Y.-F., Gao, C., Zhang, D., Cheng, Q., Wei, J., Zhang, Q.-W., & Wang, R. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c00192 · Cited by 19
(2017) · PubMed
Metadata
- Authors
- Schulze, K., López, D. A., Tillich, U. M., & Frohme, M.
- Venue
- BMC Biotechnology
- Published
- 2011-11-30
- Volume
- 11
- Issue
- 1
- Pages
- 118-118
- ISSN
- 1472-6750 (ISSN-L)
- OpenAlex
- W2054847069
- Cited by
- 101
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple viability analysis for unicellular cyanobacteria using a new autofluorescence assay, automated microscopy, and ImageJ. https://app.cochat.ai/papers/10.1186/1472-6750-11-118
- The paper
- Schulze, K., López, D. A., Tillich, U. M., & Frohme, M. (2011). A simple viability analysis for unicellular cyanobacteria using a new autofluorescence assay, automated microscopy, and ImageJ. BMC Biotechnology. https://doi.org/10.1186/1472-6750-11-118
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.