Routes to improving the reliability of low level DNA analysis using real-time PCR

Open access

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Background: Accurate quantification of DNA using quantitative real-time PCR at low levels is increasingly important for clinical, environmental and forensic applications. At low concentration levels (here referring to under 100 target copies) DNA quantification is sensitive to losses during preparation, and suffers from appreciable valid non-detection rates for sampling reasons. This paper reports studies on a real-time quantitative PCR assay targeting a region of the human SRY gene over a concentration range of 0.5 to 1000 target copies. The effects of different sample preparation and calibration methods on quantitative accuracy were investigated. Results: At very low target concentrations of 0.5–10 genome equivalents (g.e.) eliminating any replicates within each DNA standard concentration with no measurable signal (non-detects) compromised calibration. Improved calibration could be achieved by eliminating all calibration replicates for any calibration standard concentration with non-detects ('elimination by sample'). Test samples also showed positive bias if non-detects were removed prior to averaging; less biased results were obtained by converting to concentration, including non-detects as zero concentration, and averaging all values. Tube plastic proved to have a strongly significant effect on DNA quantitation at low levels ( p = 1.8 × 10 -4 ). At low concentrations (under 10 g.e.), results for assays prepared in standard plastic were reduced by about 50% compared to the low-retention plastic. Preparation solution (carrier DNA or stabiliser) was not found to have a significant effect in this study. Detection probabilities were calculated using logistic regression. Logistic regression over large concentration ranges proved sensitive to non-detected replicate reactions due to amplification failure at high concentrations; the effect could be reduced by regression against log (concentration) or, better, by eliminating invalid responses. Conclusion: Use of low-retention plastic tubes is advised for quantification of DNA solutions at levels below 100 g.e. For low-level calibration using linear least squares, it is better to eliminate the entire replicate group for any standard that shows non-detects reasonably attributable to sampling effects than to either eliminate non-detects or to assign arbitrary high Ct values. In calculating concentrations for low-level test samples with non-detects, concentrations should be calculated for each replicate, zero concentration assigned to non-detects, and all resulting concentration values averaged. Logistic regression is a useful method of estimating detection probability at low DNA concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1472-6750-6-33

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Figures

Boxplot of concentration z score by Condition Figure 1 Boxplot of concentration z score by Condition . Base: All observations for concentrations 0.5-1000. See Table 1 for preparative condition details. Briefly: Conditions 1-3 are standard plastic tubes and conditions 4-6 low-retention plastic. Pairs (1,4), (2,5) and 3,6) correspond to water, stabilising solution and carrier DNA solutions respectively.
Boxplot of concentration z score by Condition Figure 1 Boxplot of concentration z score by Condition . Base: All observations for concentrations 0.5-1000. See Table 1 for preparative condition details. Briefly: Conditions 1-3 are standard plastic tubes and conditions 4-6 low-retention plastic. Pairs (1,4), (2,5) and 3,6) correspond to water, stabilising solution and carrier DNA solutions respectively.CC-BY · From the PDF
Effect of tube plastic on DNA quantitation Figure 2 Effect of tube plastic on DNA quantitation . Notched box plot of concentration z-core against plastic type. Notches show approximate 95% confidence intervals for the median; non-overlapping notches (as here) indicate significant difference. Base: All observations for concentrations 0.51000.
Effect of tube plastic on DNA quantitation Figure 2 Effect of tube plastic on DNA quantitation . Notched box plot of concentration z-core against plastic type. Notches show approximate 95% confidence intervals for the median; non-overlapping notches (as here) indicate significant difference. Base: All observations for concentrations 0.51000.CC-BY · From the PDF
Effect of low retention plastic by concentration Figure 3 Effect of low retention plastic by concentration . The figure shows the ratio of mean predicted concentrations (C) for low-retention and standard plastic tubes (the ratio is mean(low ret.)/mean(standard)), grouped by nominal concentration (copy number). Note that low-concentration groups include non-amplification events; the ratios partly reflect the reduced incidence of non-amplifications in lowretention tubes. Means were calculated from all observations for concentrations 0.5-1000.
Effect of low retention plastic by concentration Figure 3 Effect of low retention plastic by concentration . The figure shows the ratio of mean predicted concentrations (C) for low-retention and standard plastic tubes (the ratio is mean(low ret.)/mean(standard)), grouped by nominal concentration (copy number). Note that low-concentration groups include non-amplification events; the ratios partly reflect the reduced incidence of non-amplifications in lowretention tubes. Means were calculated from all observations for concentrations 0.5-1000.CC-BY · From the PDF
Calibration for low level DNA quantification Figure 4 Calibration for low level DNA quantification . Base: All valid observations. The figure shows mean values at each concentration with a) (filled circles ● ) negative observations excluded; b) (open circles o) all values including negative observations taken as Ct = 55 (the means coincide at log 10 (C)>0.5). Regression lines are the exclusion-by-sample regression (solid line), the line through means with negative observations excluded (dashed line) and the line through means with negative observations set to Ct = 55 (dotted line).
Calibration for low level DNA quantification Figure 4 Calibration for low level DNA quantification . Base: All valid observations. The figure shows mean values at each concentration with a) (filled circles ● ) negative observations excluded; b) (open circles o) all values including negative observations taken as Ct = 55 (the means coincide at log 10 (C)>0.5). Regression lines are the exclusion-by-sample regression (solid line), the line through means with negative observations excluded (dashed line) and the line through means with negative observations set to Ct = 55 (dotted line).CC-BY · From the PDF
Logistic regression of detection probability Figure 5 Logistic regression of detection probability . Logistic regression of a) (solid line) p(positive) vs. concentration C with false negative at log 10 (C) omitted; b) (dashed line) p(positive) vs. log 10 (C) with false negative included. Solid points show fraction of positives at each concentration with the false negative omitted; the open circle shows the calculated fraction at log 10 (C) with the false negative included. The apparent lower limit to the solid curve is an artefact of plotting on the log 10 axis.
Logistic regression of detection probability Figure 5 Logistic regression of detection probability . Logistic regression of a) (solid line) p(positive) vs. concentration C with false negative at log 10 (C) omitted; b) (dashed line) p(positive) vs. log 10 (C) with false negative included. Solid points show fraction of positives at each concentration with the false negative omitted; the open circle shows the calculated fraction at log 10 (C) with the false negative included. The apparent lower limit to the solid curve is an artefact of plotting on the log 10 axis.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 230

Metadata

Authors
Ellison, S. L., English, C. A., Burns, M. J., & Keer, J. T.
Affiliations
LGC (GB)
Corresponding author
Ellison, Stephen LR
Venue
BMC Biotechnology
Published
2006-07-06
Volume
6
Issue
1
Pages
33-33
ISSN
1472-6750 (ISSN-L)
OpenAlex
W2146069457
Cited by
207
References
24
Citations by year
2026: 10 · 2025: 13 · 2024: 9 · 2023: 10 · 2022: 17 · 2021: 15 · 2020: 10 · 2019: 15 · 2018: 40 · 2017: 10 · 2016: 12 · 2015: 5 · 2014: 8 · 2013: 8 · 2012: 7
FWCI
1.63
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BMC Biotechnology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Genetic diversity and population structure
Keywords
real-time quantitative PCR, SRY gene, detection probability, logistic regression, sample preparation, forensic DNA analysis
MeSH terms
Base Sequence, Computer Simulation, Computer Systems, Microchemistry, Models, Genetic, Molecular Sequence Data, Quality Control, Sensitivity and Specificity, Specimen Handling, Reproducibility of Results, Artifacts, Sequence Analysis, DNA, Reverse Transcriptase Polymerase Chain Reaction, Oligonucleotide Array Sequence Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Routes to improving the reliability of low level DNA analysis using real-time PCR. https://app.cochat.ai/papers/10.1186/1472-6750-6-33
The paper
Ellison, S. L., English, C. A., Burns, M. J., & Keer, J. T. (2006). Routes to improving the reliability of low level DNA analysis using real-time PCR. BMC Biotechnology. https://doi.org/10.1186/1472-6750-6-33

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.