Effects of automated alerts on unnecessarily repeated serology tests in a cardiovascular surgery department: a time series analysis
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Laboratory testing is frequently unnecessary, particularly repetitive testing. Among the interventions proposed to reduce unnecessary testing, Computerized Decision Support Systems (CDSS) have been shown to be effective, but their impact depends on their technical characteristics. The objective of the study was to evaluate the impact of a Serology-CDSS providing point of care reminders of previous existing serology results, embedded in a Computerized Physician Order Entry at a university teaching hospital in Paris, France. METHODS: A CDSS was implemented in the Cardiovascular Surgery department of the hospital in order to decrease inappropriate repetitions of viral serology tests (HBV).A time series analysis was performed to assess the impact of the alert on physicians' practices. The study took place between January 2004 and December 2007. The primary outcome was the proportion of unnecessarily repeated HBs antigen tests over the periods of the study. A test was considered unnecessary when it was ordered within 90 days after a previous test for the same patient. A secondary outcome was the proportion of potentially unnecessary HBs antigen test orders cancelled after an alert display. RESULTS: In the pre-intervention period, 3,480 viral serology tests were ordered, of which 538 (15.5%) were unnecessarily repeated. During the intervention period, of the 2,095 HBs antigen tests performed, 330 unnecessary repetitions (15.8%) were observed. Before the intervention, the mean proportion of unnecessarily repeated HBs antigen tests increased by 0.4% per month (absolute increase, 95% CI 0.2% to 0.6%, p < 0.001). After the intervention, a significant trend change occurred, with a monthly difference estimated at -0.4% (95% CI -0.7% to -0.1%, p = 0.02) resulting in a stable proportion of unnecessarily repeated HBs antigen tests. A total of 380 unnecessary tests were ordered among 500 alerts displayed (compliance rate 24%). CONCLUSIONS: The proportion of unnecessarily repeated tests immediately dropped after CDSS implementation and remained stable, contrasting with the significant continuous increase observed before. The compliance rate confirmed the effect of the alerts. It is necessary to continue experimentation with dedicated systems in order to improve understanding of the diversity of CDSS and their impact on clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Segmented regression analysis of interrupted time series studies in medication use research
Wagner, A. K., Soumerai, S. B., Zhang, F., & Ross-Degnan, D. (2002) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1046/j.1365-2710.2002.00430.x · Cited by 3,279 · cited 2×
“We used a segmented regression analysis to determine the impact of the intervention, both immediately (change in level) as well as over time (change in trend) [18,21].”
MethodGarg, A. X., Adhikari, N. K. J., McDonald, H., Rosas-Arellano, M. P., Devereaux, P. J., Beyene, J., Sam, J., & Haynes, R. B. (2005) · JAMA · doi:10.1001/jama.293.10.1223 · Cited by 2,936
Research designs for studies evaluating the effectiveness of change and improvement strategies
Eccles, M. (2003) · Quality and Safety in Health Care · doi:10.1136/qhc.12.1.47 · Cited by 586
Improving Outcomes with Clinical Decision Support: An Implementer's Guide, Second Edition
Osheroff, J. (2012) · doi:10.4324/9781498757461 · Cited by 517
Bates, D. W., Kuperman, G. J., Rittenberg, E., Teich, J. M., Fiskio, J., Ma’luf, N., Onderdonk, A., Wybenga, D., Winkelman, J., Brennan, T. A., et al. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00410-0 · Cited by 292 · cited 3×
“However, CPOE with embedded decision-support tools could reduce such repetitive testing [11,13,14].”
BackgroundPearson, S.-A., Moxey, A., Robertson, J., Hains, I., Williamson, M., Reeve, J., & Newby, D. (2009) · BMC Health Services Research · doi:10.1186/1472-6963-9-154 · Cited by 193 · cited 1×
“They have demonstrated their efficacy in improving clinical practices and patient outcomes [1-7], particularly under the form of on-screen computer reminders [8].”
BackgroundThe Impact of Peer Management on Test-Ordering Behavior
Neilson, E. G., Johnson, K. B., Rosenbloom, S. T., Dupont, W. D., Talbert, D., Giuse, D. A., Kaiser, A., Miller, R. A., & and the Resource Utilization Committee* (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-3-200408030-00008 · Cited by 147 · cited 4×
“However, CPOE with embedded decision-support tools could reduce such repetitive testing [11,13,14].”
BackgroundInfluentialMollon, B., Chong, J. J., Holbrook, A. M., Sung, M., Thabane, L., & Foster, G. (2009) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-9-11 · Cited by 124 · cited 1×
“They have demonstrated their efficacy in improving clinical practices and patient outcomes [1-7], particularly under the form of on-screen computer reminders [8].”
BackgroundKilbridge, P. M. (2006) · Quality and Safety in Health Care · doi:10.1136/qshc.2005.014969 · Cited by 72
Cited by
Benefits and drawbacks of electronic health record systems
Menachemi, N., & Collum (2011) · Risk Management and Healthcare Policy · doi:10.2147/rmhp.s12985 · Cited by 909
The Landscape of Inappropriate Laboratory Testing: A 15-Year Meta-Analysis
Zhi, M., Ding, E. L., Theisen-Toupal, J., Whelan, J., & Arnaout, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0078962 · Cited by 535
Health IT and Patient Safety: Building Safer Systems for Better Care
Chou, D. (2012) · JAMA · doi:10.1001/jama.308.21.2282-a · Cited by 503
Interventions Aimed at Reducing Use of Low-Value Health Services: A Systematic Review
Colla, C. H., Mainor, A. J., Hargreaves, C., Sequist, T., & Morden, N. (2017) · Medical Care Research and Review · doi:10.1177/1077558716656970 · Cited by 357
Stelfox, H. T., Leigh, J. P., Dodek, P. M., Turgeon, A. F., Forster, A. J., Lamontagne, F., Fowler, R. A., Soo, A., & Bagshaw, S. M. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4910-1 · Cited by 70
Metadata
- Authors
- Niès, J., Colombet, I., Zapletal, E., Gillaizeau, F., Chevalier, P., & Durieux, P.
- Venue
- BMC Health Services Research
- Published
- 2010-03-19
- Volume
- 10
- Issue
- 1
- Pages
- 70-70
- ISSN
- 1472-6963 (ISSN-L)
- OpenAlex
- W2023574292
- Cited by
- 44
- References
- 9
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of automated alerts on unnecessarily repeated serology tests in a cardiovascular surgery department: a time series analysis. https://app.cochat.ai/papers/10.1186/1472-6963-10-70
- The paper
- Niès, J., Colombet, I., Zapletal, E., Gillaizeau, F., Chevalier, P., & Durieux, P. (2010). Effects of automated alerts on unnecessarily repeated serology tests in a cardiovascular surgery department: a time series analysis. BMC Health Services Research. https://doi.org/10.1186/1472-6963-10-70
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.