The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Impact of a large-scale educational intervention program on venous blood specimen collection practices
Open accessAbstract
BACKGROUND: Phlebotomy performed with poor adherence to venous blood specimen collection (VBSC) guidelines jeopardizes patient safety and may lead to patient suffering and adverse events. A first questionnaire study demonstrated low compliance to VBSC guidelines, motivating an educational intervention of all phlebotomists within a county council. The aim was to evaluate the impact of a large-scale educational intervention program (EIP) on primary health care phlebotomists' adherence to VBSC guidelines. We hypothesised that the EIP would improve phlebotomists' VBSC practical performance. METHODS: The present study comprise primary health care centres (n = 61) from two county councils in northern Sweden. The final selected study group consisted of phlebotomists divided into an intervention group (n = 84) and a corresponding control group (n = 79). Both groups responded to a validated self-reported VBSC questionnaire twice. The EIP included three parts: guideline studies, an oral presentation, and an examination. Non-parametric statistics were used for comparison within and between the groups. RESULTS: Evaluating the EIP, we found significant improvements in the intervention group compared to the control group on self-reported questionnaire responses regarding information search (ES = 0.23-0.33, p < 0.001-0.003), and patient rest prior to phlebotomy (ES = 0.27, p = 0.004). Test request management, patient identity control, release of venous stasis, and test tube labelling had significantly improved in the intervention group but did not significantly differ from the control group (ES = 0.22- 0.49, p = < 0.001- 0.006). The control group showed no significant improvements at all (ES = 0-0.39, p = 0.016-0.961). CONCLUSIONS: The present study demonstrated several significant improvements on phlebotomists' adherence to VBSC practices. Still, guideline adherence improvement to several crucial phlebotomy practices is needed. We cannot conclude that the improvements are solely due to the EIP and suggest future efforts to improve VBSC. The program should provide time for reflections and discussions. Furthermore, a modular structure would allow directed educational intervention based on the specific VBSC guideline flaws existing at a specific unit. Such an approach is probably more effective at improving and sustaining adherence to VBSC guidelines than an EIP containing general pre-analytical practices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SPSS survival manual : a step by step guide to data analysis using SPSS
Pallant, J. (2010) · Cited by 6,888
SPSS Survival Manual: A Step by Step Guide to Data Analysis using IBM SPSS
Pallant, J. (2020) · Routledge eBooks · doi:10.4324/9781003117407 · Cited by 5,201
From best evidence to best practice: effective implementation of change in patients' care
Grol, R., & Grimshaw, J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14546-1 · Cited by 4,531
(2009) · US Department of Education · Cited by 3,654
(2007) · Cited by 3,005
Francke, A. L., Smit, M. C., de Veer, A. J., & Mistiaen, P. (2008) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-8-38 · Cited by 1,134 · cited 4×
“Multiple components such as the lack of awareness, agreement with, or limited familiarity with guidelines [27], lack of support from the clinic or superiors, and time constraints or understaffing appear to be the main impediments for successful implementation of guidelines [27,34].”
BackgroundInfluentialErrors in clinical laboratories or errors in laboratory medicine?
Plebani, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.123 · Cited by 734 · cited 8×
“Common specimen handling errors include incorrect test tube labelling [2,15,20,21], incorrect test request management, missing tubes, and transport errors [2,8,10,14,22].”
BackgroundInfluentialErrors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670 · cited 6×
“Common specimen handling errors include incorrect test tube labelling [2,15,20,21], incorrect test request management, missing tubes, and transport errors [2,8,10,14,22].”
BackgroundInfluentialHow can we improve guideline use? A conceptual framework of implementability
Gagliardi, A. R., Brouwers, M. C., Palda, V. A., Lemieux-Charles, L., & Grimshaw, J. M. (2011) · Implementation Science · doi:10.1186/1748-5908-6-26 · Cited by 472 · cited 4×
“There are few evaluations of how guidelines should be effectively implemented, and it is often unclear who is responsible for implementing and sustaining guideline knowledge and practices [34].”
BackgroundInfluentialHaemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466 · cited 2×
“During the 2-hours lecture, emphasis was put on how to avoid haemolysis as well [19,31].”
Background
Research works printed but not linked: 2
- Clinical and Laboratory Standards Institute: Procedures for the collection of diagnostic blood specimens by venipuncture. Approved Standard. 2007, Wayne: CLSI document H3-A6, 6
- Cohen J: Statistical power analysis for the behavioural sciences. 1988, Hillsdale: L. Erlbaum Associates
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationCauses, consequences and management of sample hemolysis in the clinical laboratory
Heireman, L., Geel, P. V., Musger, L., Heylen, E., Uyttenbroeck, W., & Mahieu, B. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.09.013 · Cited by 172
Bölenius, K., Brulin, C., & Graneheim, U. H. (2014) · Nursing Research and Practice · doi:10.1155/2014/538704 · Cited by 63
“These results are confirmed by our previous study showing that phlebotomy personnel significantly improved control of patients’ photo identification [25].”
BackgroundMethodResultInfluentialSelf-citationThe preanalytical phase – Past, present and future
Cornes, M. P. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219867989 · Cited by 28
Approaching sustainability in Laboratory Medicine
Thakur, A., Mukhopadhyay, T., & Ahirwar, A. K. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0973 · Cited by 26
“Best phlebotomy practices ensure the right site preparation, selection of the correct blood collection container fi lled in the right sequence up till the recommended volume with adequate mixing [18, 19].”
Background
Metadata
- Authors
- Bölenius, K., Lindkvist, M., Brulin, C., Grankvist, K., Nilsson, K., & Söderberg, J.
- Affiliations
- Umeå University (SE)
- Corresponding author
- Bölenius, Karin
- Venue
- BMC Health Services Research
- Published
- 2013-11-05
- Volume
- 13
- Issue
- 1
- Pages
- 463-463
- ISSN
- 1472-6963 (ISSN-L)
- PMC
- PMC4228245
- OpenAlex
- W2102897327
- Semantic Scholar
- 0a85f15a0ce76b641c882af10a7957ccc31251dd
- Cited by
- 30
- References
- 49
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 3 · 2018: 3 · 2017: 5 · 2016: 1 · 2015: 3 · 2014: 1
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMC Health Services Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
- Funders
- Umeå Universitet
- Socialstyrelsen
- Medicinska fakulteten, Umeå Universitet
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Social Sciences › Education › Innovations in Medical Education
- Keywords
- phlebotomy, guideline adherence, educational intervention, phlebotomists, primary care, pre-analytical quality, patient safety, venous stasis, information search, self-reported practices, northern Sweden, pre-analytical variability
- MeSH terms
- Adult, Aged, Blood Specimen Collection, Female, Humans, Male, Middle Aged, Surveys and Questionnaires, Program Evaluation, Medical Laboratory Personnel, Phlebotomy, Guideline Adherence
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of a large-scale educational intervention program on venous blood specimen collection practices. https://app.cochat.ai/papers/10.1186/1472-6963-13-463
- The paper
- Bölenius, K., Lindkvist, M., Brulin, C., Grankvist, K., Nilsson, K., & Söderberg, J. (2013). Impact of a large-scale educational intervention program on venous blood specimen collection practices. BMC Health Services Research. https://doi.org/10.1186/1472-6963-13-463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
