Real-time PCR assay and rapid diagnostic tests for the diagnosis of clinically suspected malaria patients in Bangladesh
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: More than 95% of total malaria cases in Bangladesh are reported from the 13 high endemic districts. Plasmodium falciparum and Plasmodium vivax are the two most abundant malaria parasites in the country. To improve the detection and management of malaria patients, the National Malaria Control Programme (NMCP) has been using rapid diagnostic test (RDT) in the endemic areas. A study was conducted to establish a SYBR Green-based modified real-time PCR assay as a gold standard to evaluate the performance of four commercially-available malaria RDTs, along with the classical gold standard- microscopy. METHODS: Blood samples were collected from 338 febrile patients referred for the diagnosis of malaria by the attending physician at MatirangaUpazila Health Complex (UHC) from May 2009 to August 2010. Paracheck RDT and microscopy were performed at the UHC. The blood samples were preserved in EDTA tubes. A SYBR Green-based real-time PCR assay was performed and evaluated. The performances of the remaining three RDTs (Falcivax, Onsite Pf and Onsite Pf/Pv) were also evaluated against microscopy and real-time PCR using the stored blood samples. RESULT: In total, 338 febrile patients were enrolled in the study. Malaria parasites were detected in 189 (55.9%) and 188 (55.6%) patients by microscopy and real-time PCR respectively. Among the RDTs, the highest sensitivity for the detection of P. falciparum (including mixed infection) was obtained by Paracheck [98.8%, 95% confidence interval (CI) 95.8-99.9] and Falcivax (97.6%, 95% CI 94.1-99.4) compared to microscopy and real-time PCR respectively. Paracheck and Onsite Pf/Pv gave the highest specificity (98.8%, 95% CI 95.7-99.9) compared to microscopy and Onsite Pf/Pv (98.8, 95% CI 95.8-99.9) compared to real-time PCR respectively for the detection of P. falciparum. On the other hand Falcivax and Onsite Pf/Pv had equal sensitivity (90.5%, 95% CI 69.6-98.8) and almost 100% specificity compared to microscopy for the detection of P. vivax. However, compared to real-time PCR assay RDTs and microscopy gave low sensitivity (76.9%, 95% CI 56.4-91) in detecting of P. vivax although a very high specificity was obtained (99-100%). CONCLUSION: The results of this study suggest that the SYBR Green-based real-time PCR assay could be used as an alternative gold standard method in a reference setting. Commercially-available RDTs used in the study are quite sensitive and specific in detecting P. falciparum, although their sensitivity in detecting P. vivax was not satisfactory compared to the real-time PCR assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perandin, F., Manca, N., Calderaro, A., Piccolo, G., Galati, L., Ricci, L., Medici, M. C., Arcangeletti, M. C., Snounou, G., Dettori, G., et al. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.3.1214-1219.2004 · Cited by 354 · cited 5×
“Real-time PCR was done by the primer sets described by Perandin et al [ 15 ] with some modification to a singleplex reaction.”
BackgroundMethodInfluentialReal-Time PCR for Detection and Identification of Plasmodium spp
Mangold, K. A., Manson, R. U., Koay, E. S. C., Stephens, L., Regner, M., Thomson, R. B., Peterson, L. R., & Kaul, K. L. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.5.2435-2440.2005 · Cited by 278 · cited 1×
“In recent time, real-time PCR method has been established for the quantitative detection of malaria parasites [15-19].”
MethodRapid diagnostic testing for malaria
Murray, C. K., Bell, D., Gasser, R. A., & Wongsrichanalai, C. (2003) · Tropical Medicine & International Health · doi:10.1046/j.1365-3156.2003.01115.x · Cited by 157
Khairnar, K., Martin, D., Lau, R., Ralevski, F., & Pillai, D. R. (2009) · Malaria Journal · doi:10.1186/1475-2875-8-284 · Cited by 101 · cited 2×
“Pf/Pv) for the detection of P. vivax compared to realtime PCR assay in this present study is similar to studies published earlier [ 20 ,26].”
MethodResultSingh, N., Shukla, M. M., Shukla, M. K., Mehra, R. K., Sharma, S., Bharti, P. K., Singh, M. P., Singh, A., & Gunasekar, A. (2010) · Malaria Journal · doi:10.1186/1475-2875-9-191 · Cited by 76 · cited 2×
“study in India, high NPV was also recorded for Falcivax RDT [13].”
Background
Cited by
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Fuhad, K. M. F., Tuba, J. F., Sarker, M. R. A., Momen, S., Mohammed, N., & Rahman, T. (2020) · Diagnostics · doi:10.3390/diagnostics10050329 · Cited by 185
“Many techniques have been reported, in the literature, which detects malarial parasites in a patient such as clinical diagnosis [3,4], microscopic diagnosis [5–10], rapid diagnostic test (RDT) [11– 13] and polymerase chain reaction (PCR) [14–16].”
BackgroundKhan, W. A., Galagan, S. R., Prue, C. S., Khyang, J., Ahmed, S., Ram, M., Alam, M. S., Haq, M. Z., Akter, J., Glass, G., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0098442 · Cited by 67
“vivax, respectively) in febrile patients who typically present with a medium-high parasite density [25].”
BackgroundSelf-citationElahi, R., Mohon, A. N., Khan, W. A., Haque, R., & Alam, M. S. (2013) · Malaria Journal · doi:10.1186/1475-2875-12-378 · Cited by 10
Self-citation
Metadata
- Authors
- Alam, M. S., Mohon, A. N., Mustafa, S., Khan, W. A., Islam, N., Karim, M. J., Khanum, H., Sullivan, D. J., & Haque, R.
- Venue
- Malaria Journal
- Published
- 2011-06-26
- Volume
- 10
- Issue
- 1
- Pages
- 175-175
- ISSN
- 1475-2875 (ISSN-L)
- OpenAlex
- W2106889709
- Cited by
- 69
- References
- 5
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time PCR assay and rapid diagnostic tests for the diagnosis of clinically suspected malaria patients in Bangladesh. https://app.cochat.ai/papers/10.1186/1475-2875-10-175
- The paper
- Alam, M. S., Mohon, A. N., Mustafa, S., Khan, W. A., Islam, N., Karim, M. J., Khanum, H., Sullivan, D. J., & Haque, R. (2011). Real-time PCR assay and rapid diagnostic tests for the diagnosis of clinically suspected malaria patients in Bangladesh. Malaria Journal. https://doi.org/10.1186/1475-2875-10-175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.