Validation of 24-hour ambulatory gait assessment in Parkinson's disease with simultaneous video observation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Parkinson's disease (PD) is a neurodegenerative disorder resulting in motor disturbances that can impact normal gait. Although PD initially responds well to pharmacological treatment, as the disease progresses efficacy often fluctuates over the course of the day, and clinical management would benefit from long-term objective measures of gait. We have previously described a small device worn on the shank that uses acceleration and angular velocity sensors to calculate stride length and identify freezing of gait in PD patients. In this study we extend validation of the gait monitor to 24-h using simultaneous video observation of PD patients. METHODS: A sleep laboratory was adapted to perform 24-hr video monitoring of patients while wearing the device. Continuous video monitoring of a sleep lab, hallway, kitchen and conference room was performed using a 4-camera security system and recorded to hard disk. Subjects (3) wore the gait monitor on the left shank (just above the ankle) for a 24-h period beginning around 5 pm in the evening. Accuracy of stride length measures were assessed at the beginning and end of the 24-h epoch. Two independent observers rated the video logs to identify when subjects were walking or lying down. RESULTS: The mean error in stride length at the start of recording was 0.05 m (SD 0) and at the conclusion of the 24 h epoch was 0.06 m (SD 0.026). There was full agreement between observer coding of the video logs and the output from the gait monitor software; that is, for every video observation of the subject walking there was a corresponding pulse in the monitor data that indicated gait. CONCLUSIONS: The accuracy of ambulatory stride length measurement was maintained over the 24-h period, and there was 100% agreement between the autonomous detection of locomotion by the gait monitor and video observation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ambulatory monitoring of freezing of gait in Parkinson’s disease
Moore, S. T., MacDougall, H. G., & Ondo, W. G. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.08.023 · Cited by 526 · cited 1×
“In Parkinson’s patients, the gait monitor has demonstrated sensitivity to motor fluctuations (rapid changes in stride length) following levodopa administration over short epochs (up to 3 h) [15,16] and can reliably detect episodes of freezing of gait from the frequency characteristics of vertical leg acceleration [17].”
Background
Cited by
Quantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374
“For example, a small device with acceleration and angular velocity sensors worn on the shank has been used to assess stride length over a 24-hour period.(20) The investigators found a 100% agreement between the stride length measurement assessed with the wearable sensors, and video observation.”
MethodContinuous Monitoring of Turning in Patients with Movement Disability
El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L. (2013) · Sensors · doi:10.3390/s140100356 · Cited by 258
“Sensors, including accelerometers and gyroscopes, have widely been used in wearable systems to quantify balance [10,11], characterize gait [12–15], evaluate fall risk [16] and detect FoG [17–21].”
BackgroundObjective Assessment of Fall Risk in Parkinson's Disease Using a Body-Fixed Sensor Worn for 3 Days
Weiss, A., Herman, T., Giladi, N., & Hausdorff, J. M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096675 · Cited by 225
Remote Physical Activity Monitoring in Neurological Disease: A Systematic Review.
Block, V. A. J., Pitsch, E., Tahir, P., Cree, B. A. C., Allen, D. D., & Gelfand, J. M. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154335 · Cited by 198
“Pan et al, 2007 [138] Mild /severe ECOLOG (Ruputer Pro, Seiko Instruments) Walking /gait/ LE physical activity Crosssectional > 50 19 6 2–6 days Government /Private foundation”
BackgroundA comparison of clinical and objective measures of freezing of gait in Parkinson's disease
Morris, T. R., Cho, C., Dilda, V., Shine, J. M., Naismith, S. L., Lewis, S. J. G., & Moore, S. T. (2012) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2012.03.001 · Cited by 114
Self-citation
Metadata
- Authors
- Moore, S. T., Dilda, V., Hakim, B., & MacDougall, H. G.
- Venue
- BioMedical Engineering OnLine
- Published
- 2011
- Volume
- 10
- Issue
- 1
- Pages
- 82
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2119004004
- Cited by
- 43
- References
- 1
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of 24-hour ambulatory gait assessment in Parkinson's disease with simultaneous video observation. https://app.cochat.ai/papers/10.1186/1475-925x-10-82
- The paper
- Moore, S. T., Dilda, V., Hakim, B., & MacDougall, H. G. (2011). Validation of 24-hour ambulatory gait assessment in Parkinson's disease with simultaneous video observation. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-10-82
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.