ScanImage: Flexible software for operating laser scanning microscopes
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Laser scanning microscopy is a powerful tool for analyzing the structure and function of biological specimens. Although numerous commercial laser scanning microscopes exist, some of the more interesting and challenging applications demand custom design. A major impediment to custom design is the difficulty of building custom data acquisition hardware and writing the complex software required to run the laser scanning microscope. RESULTS: We describe a simple, software-based approach to operating a laser scanning microscope without the need for custom data acquisition hardware. Data acquisition and control of laser scanning are achieved through standard data acquisition boards. The entire burden of signal integration and image processing is placed on the CPU of the computer. We quantitate the effectiveness of our data acquisition and signal conditioning algorithm under a variety of conditions. We implement our approach in an open source software package (ScanImage) and describe its functionality. CONCLUSIONS: We present ScanImage, software to run a flexible laser scanning microscope that allows easy custom design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex
Trachtenberg, J. T., Chen, B. E., Knott, G. W., Feng, G., Sanes, J. R., Welker, E., & Svoboda, K. (2002) · Nature · doi:10.1038/nature01273 · Cited by 1,927
Self-citationHandbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Horowitz, P., Hill, W., & Rollefson, R. J. (1990) · American Journal of Physics · doi:10.1119/1.16385 · Cited by 1,487
Cell Biology: a Laboratory Handbook
Harris, A. (1995) · Journal of Medical Genetics · doi:10.1136/jmg.32.9.759 · Cited by 1,225
Horowitz, P., & Hill, W. (2015) · Cited by 1,195
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
Self-citationAnatomical and functional imaging of neurons using 2-photon laser scanning microscopy
Denk, W., Delaney, K. R., Gelperin, A., Kleinfeld, D., Strowbridge, B. W., Tank, D. W., & Yuste, R. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90189-9 · Cited by 348
Facilitation at single synapses probed with optical quantal analysis
Oertner, T. G., Sabatini, B. L., Nimchinsky, E. A., & Svoboda, K. (2002) · Nature Neuroscience · doi:10.1038/nn867 · Cited by 323
Self-citationTwo-Photon Imaging in Living Brain Slices
Mainen, Z. F., Maletic-Savatic, M., Shi, S. H., Hayashi, Y., Malinow, R., & Svoboda, K. (1999) · Methods · doi:10.1006/meth.1999.0776 · Cited by 175
Self-citation
Cited by
Items 201–204 of 204
Ren, B., Burkovetskaya, M., Jung, Y., Bergdolt, L., Totusek, S., Martinez‐Cerdeno, V., Stauch, K., Korade, Z., & Dunaevsky, A. (2023) · Glia · doi:10.1002/glia.24331 · Cited by 18
“Scan-Image software written in MATLAB (Math-Works) was used to acquire the images (Pologruto et al., 2003).”
MethodMultimodal cue integration and learning in a neural representation of head direction
Basnak, M. A., Kutschireiter, A., Okubo, T. S., Chen, A., Gorelik, P., Drugowitsch, J., & Wilson, R. I. (2025) · Nature Neuroscience · doi:10.1038/s41593-024-01823-z · Cited by 13
Scudder, S. L., Gonzales, F. R., Howell, K. K., Stein, I. S., Dozier, L. E., Anagnostaras, S. G., Zito, K., & Patrick, G. N. (2021) · eNeuro · doi:10.1523/eneuro.0073-20.2021 · Cited by 10
“Time-Lapse Imaging and Image Analysis for spine dynamics EGFP-transfected CA1 pyramidal neurons [7-9 days in vitro (DIV)] at depths of 10-50 µm were imaged using a custom two-photon microscope (Woods et al., 2011) controlled with ScanImage (Pologruto et al., 2003).”
MethodCoexistence of state, choice, and sensory integration coding in barrel cortex LII/III
Gardères, P.-M., Le Gal, S., Rousseau, C., Mamane, A., Ganea, D. A., & Haiss, F. (2024) · Nature Communications · doi:10.1038/s41467-024-49129-9 · Cited by 7
“Two-photon laser scanning was controlled using the ScanImage software 2018 88 .”
Metadata
- Authors
- Pologruto, T. A., Sabatini, B. L., & Svoboda, K.
- Venue
- BioMedical Engineering OnLine
- Published
- 2003-05-17
- Volume
- 2
- Issue
- 1
- Pages
- 13-13
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2121071682
- Cited by
- 1,294
- References
- 16
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.