Biological effects of exposure to magnetic resonance imaging: an overview
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to allow the integration of the specific literature on the bio-effects produced by magnetic resonance systems with the vast literature concerning the bio-effects produced by electromagnetic fields. This work gives an overview of the findings about the safety concerns of exposure to static magnetic fields, radio-frequency fields, and time varying magnetic field gradients, focusing primarily on the physics of the interactions between these electromagnetic fields and biological matter. The scientific literature is summarized, integrated, and critically analyzed with the help of authoritative reviews by recognized experts, international safety guidelines are also cited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ahlbom, A. (1998) · Health Physics · Cited by 5,817
Herbertz, J. (1998) · PubMed · Cited by 598
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436 · cited 7×
“Schenck JF, Dumoulin CL, Redington RW, Kressel HY, Elliott RT, McDougall IL: Human exposure to 4.0 T magnetic fields in a whole-body scanner.”
BackgroundInfluentialBook of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 395
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s · Cited by 343 · cited 6×
“Numerous studies carried out over the past 35 years have indicated that the exposure to radiofrequency radiation may produce various physiological effects, due to RF energy-induced heating in tissues, including those associated with alterations in visual, auditory, endocrine, neural, cardiovascular, immune, reproducti…”
BackgroundInfluentialFree radical mechanism for the effects of environmental electromagnetic fields on biological systems
BROCKLEHURST, B., & McLAUCHLAN, K. A. (1996) · International Journal of Radiation Biology · doi:10.1080/095530096146147 · Cited by 323 · cited 1×
“In fact, according to the most accepted theory [38-40], the magnetic field splits the radical pairs into two energy levels, this increases the amount of radicals pairs that escape the recombination reaction [41], i.”
BackgroundPeripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields
Reilly, J. P. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446217 · Cited by 293 · cited 2×
“5 T exposure and, when corrected for pulse shape and pulse train length, appeared to agree roughly with the Reilly model [49] for the induced electric field required for stimulation.”
MethodReview of Patient Safety in Time-Varying Gradient Fields
Schaefer, D. J., Bourland, J. D., & Nyenhuis, J. A. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<20::aid-jmri3>3.0.co;2-y · Cited by 254 · cited 5×
“[47] collected the experimental data obtained in these studies and compared the different results reported.”
BackgroundResultInfluential
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
La Gioia, A., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 297
Biological Effects and Safety in Magnetic Resonance Imaging: A Review
Hartwig, V., Giovannetti, G., Vanello, N., Lombardi, M., Landini, L., & Simi, S. (2009) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph6061778 · Cited by 234
“size, the anatomical features and the sensitivity of the tissues [11].”
BackgroundInfluentialStimuli-responsive liposomal nanoformulations in cancer therapy: Pre-clinical & clinical approaches
Ashrafizadeh, M., Delfi, M., Zarrabi, A., Bigham, A., Sharifi, E., Rabiee, N., Paiva-Santos, A. C., Kumar, A. P., Tan, S. C., Hushmandi, K., et al. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.08.001 · Cited by 225
Plewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 220
“Furthermore, MRI does all of this in a noninvasive manner, which permits safe repeated scans with no known harm (26) when used within welldefined technical constraints (27).”
BackgroundMR Artifacts, Safety, and Quality Control
Zhuo, J., & Gullapalli, R. P. (2006) · RadioGraphics · doi:10.1148/rg.261055134 · Cited by 212
Yang, K., Yang, G., Chen, L., Cheng, L., Wang, L., Ge, C., & Liu, Z. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.052 · Cited by 185
“On the other hand, MR imaging, different from Xray computed tomography (CT) and nuclear imaging, is a relatively safe imagingmethodwithout inducing any ionizing radiation to the patients [34,37].”
Ban, Q., Bai, T., Duan, X., & Kong, J. (2017) · Biomaterials Science · doi:10.1039/c6bm00600k · Cited by 172
Whole-body adipose tissue analysis: comparison of MRI, CT and dual energy X-ray absorptiometry
KULLBERG, J., BRANDBERG, J., ANGELHED, J.-E., FRIMMEL, H., BERGELIN, E., STRID, L., AHLSTRÖM, H., JOHANSSON, L., & LÖNN, L. (2009) · The British Journal of Radiology · doi:10.1259/bjr/80083156 · Cited by 164
Metadata
- Authors
- Formica, D., & Silvestri, S.
- Venue
- BioMedical Engineering OnLine
- Published
- 2004-04-22
- Volume
- 3
- Issue
- 1
- Pages
- 11-11
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2153292125
- Cited by
- 173
- References
- 46
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.