Biological effects of exposure to magnetic resonance imaging: an overview
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to allow the integration of the specific literature on the bio-effects produced by magnetic resonance systems with the vast literature concerning the bio-effects produced by electromagnetic fields. This work gives an overview of the findings about the safety concerns of exposure to static magnetic fields, radio-frequency fields, and time varying magnetic field gradients, focusing primarily on the physics of the interactions between these electromagnetic fields and biological matter. The scientific literature is summarized, integrated, and critically analyzed with the help of authoritative reviews by recognized experts, international safety guidelines are also cited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ahlbom, A. (1998) · Health Physics · Cited by 5,817
Herbertz, J. (1998) · PubMed · Cited by 598
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436 · cited 7×
“Schenck JF, Dumoulin CL, Redington RW, Kressel HY, Elliott RT, McDougall IL: Human exposure to 4.0 T magnetic fields in a whole-body scanner.”
BackgroundInfluentialBook of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 395
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s · Cited by 343 · cited 6×
“Numerous studies carried out over the past 35 years have indicated that the exposure to radiofrequency radiation may produce various physiological effects, due to RF energy-induced heating in tissues, including those associated with alterations in visual, auditory, endocrine, neural, cardiovascular, immune, reproducti…”
BackgroundInfluentialFree radical mechanism for the effects of environmental electromagnetic fields on biological systems
BROCKLEHURST, B., & McLAUCHLAN, K. A. (1996) · International Journal of Radiation Biology · doi:10.1080/095530096146147 · Cited by 323 · cited 1×
“In fact, according to the most accepted theory [38-40], the magnetic field splits the radical pairs into two energy levels, this increases the amount of radicals pairs that escape the recombination reaction [41], i.”
BackgroundPeripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields
Reilly, J. P. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446217 · Cited by 293 · cited 2×
“5 T exposure and, when corrected for pulse shape and pulse train length, appeared to agree roughly with the Reilly model [49] for the induced electric field required for stimulation.”
MethodReview of Patient Safety in Time-Varying Gradient Fields
Schaefer, D. J., Bourland, J. D., & Nyenhuis, J. A. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<20::aid-jmri3>3.0.co;2-y · Cited by 254 · cited 5×
“[47] collected the experimental data obtained in these studies and compared the different results reported.”
BackgroundResultInfluentialMagnetic resonance safety update 2002: Implants and devices
Shellock, F. G. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10196 · Cited by 233 · cited 1×
“In fact, the MR environment may be unsafe for patients with certain implants, primarily due to movement or dislodgment of objects made from ferromagnetic materials [9], but also because of heating and induction of electrical currents, which may present risks to patients with implants or external devices [10].”
BackgroundMagnetic fields and radical reactions: recent developments and their role in nature
Brocklehurst, B. (2002) · Chemical Society Reviews · doi:10.1039/b107250c · Cited by 213 · cited 1×
“Claims that low magnetic fields damage health have led to extensive medical, chemical and physical research: though no firm evidence of hazards has emerged [44].”
BackgroundEstimating radiofrequency power deposition in body NMR imaging
Bottomley, P. A., Redington, R. W., Edelstein, W. A., & Schenck, J. F. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020404 · Cited by 171 · cited 1×
“However, especially for human subjects, measurements or estimates of the SAR levels are not trivial, because body SAR during an MRI examination is a complex function of several variables, including the frequency, the type of RF pulse used and its repetition time, the configuration of the anatomical region exposed, and…”
BackgroundSensory stimulation by time‐varying magnetic fields
Cohen, M. S., Weisskoff, R. M., Rzedzian, R. R., & Kantor, H. L. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140226 · Cited by 164 · cited 2×
“Cohen MS, Weisskoff RM, Rzedzian RR, Kantor HL: Sensory stimulation by time varying magnetic fields.”
BackgroundCognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imaging
Kangarlu, A., Burgess, R. E., Zhu, H., Nakayama, T., Hamlin, R. L., Abduljalil, A. M., & Robitaille, P. M. L. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00086-7 · Cited by 163 · cited 1×
“the stimulation of nerve or muscle cells have recently been studied in humans at field strengths as high as 8 T [34].”
BackgroundChakeres, D. W., Kangarlu, A., Boudoulas, H., & Young, D. C. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10367 · Cited by 161 · cited 1×
“, ECG recordings, have been reported at these high field strengths [35].”
BackgroundSchenck, J. F. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49617.x · Cited by 149
Human exposure to 4.0-Tesla magnetic fields in a whole-body scanner
Schenck, J. F., Dumoulin, C. L., Redington, R. W., Kressel, H. Y., Elliott, R. T., & McDougall, I. (1992) · Medical Physics · doi:10.1118/1.596827 · Cited by 149 · cited 2×
“On the other hand, a very small magneto- hydrodynamic force operating on the endolynphatic tissues of the inner ear may be the source for the sensations of nausea and vertigo sometimes reported at higher field strengths [23,36].”
BackgroundPower deposition in whole-body NMR imaging
Bottomley, P. A., & Edelstein, W. A. (1981) · Medical Physics · doi:10.1118/1.595000 · Cited by 147 · cited 1×
“However, especially for human subjects, measurements or estimates of the SAR levels are not trivial, because body SAR during an MRI examination is a complex function of several variables, including the frequency, the type of RF pulse used and its repetition time, the configuration of the anatomical region exposed, and…”
BackgroundSafe Performance of Magnetic Resonance Imaging on Five Patients with Permanent Cardiac Pacemakers
Gimbel, J., JOHNSON, D., LEVINE, P. A., & Wilkoff, B. L. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03387.x · Cited by 145 · cited 1×
“We might conclude that, by examination of current literature and within the limits of our knowledge, the only health hazards to patients significantly associated with the exposure to static magnetic fields are related to the presence of ferromagnetic materials or cardiac pacemakers [28-30].”
BackgroundThe effects of weak magnetic fields on radical recombination reactions in micelles
W. Eveson, C. R. T. (2000) · International Journal of Radiation Biology · doi:10.1080/09553000050176270 · Cited by 143 · cited 1×
“Several studies analyzed the effects of magnetic fields on the recombination reaction of radical pairs in micelles and confirmed that an externally applied magnetic field increases the number of radicals escaping the recombination reaction [37,39,43].”
BackgroundSawyer-Glover, A. M., & Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<92::aid-jmri11>3.0.co;2-7 · Cited by 143 · cited 1×
“Most reported cases of MRI related injuries have been caused by misinformation related to the MR safety aspects of metallic objects, implants, and biomedical devices [7,8].”
BackgroundPhysiological Effects of Fast Oscillating Magnetic Field Gradients
Budinger, T. F., Fischer, H., Hentschel, D., Reinfelder, H.-E., & Schmitt, F. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199111000-00001 · Cited by 141 · cited 7×
“In addition to the studies on animals, several investigators carried out gradient-induced stimulation experiments in humans: among them, Budinger [59], Cohen [60], Schaefer [61,62], Bourland [63] and Ham [64].”
BackgroundInfluentialEncyclopedia of Medical Devices and Instrumentation
Griffiths, H. J. (1989) · Radiology · doi:10.1148/radiology.170.3.1016 · Cited by 140
Tenforde, T. S., Gaffey, C. T., Moyer, B. R., & Budlnger, T. F. (1983) · Bioelectromagnetics · doi:10.1002/bem.2250040102 · Cited by 133 · cited 1×
“However, afterwards, these changes were explained by the presence of the electromotive force (EMF) induced by blood flow in a static magnetic field, which is proportional to the quantity [32, 33].”
Peripheral nerve stimulation during MRI: Effects of high gradient amplitudes and switching rates
Ham, C. L. G., Engels, J. M. L., van de Wiel, G. T., & Machielsen, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070524 · Cited by 129 · cited 3×
“Kangarlu A, Burgess RE, Zhu H, Nakayama T, Hamlin RL, Abduljalil AM, Robitaille PM: Cognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imaging.”
BackgroundMagnetohydrodynamics of blood flow
Keltner, J. R., Roos, M. S., Brakeman, P., & Budinger, T. F. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160113 · Cited by 129
Beers, G. J. (1989) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(89)90556-0 · Cited by 101 · cited 2×
“Those interested in a thorough discussion of this topic are referred to the extensive review by Beers [91].”
BackgroundScaiano, J. C., Cozens, F. L., & McLean, J. R. N. (1994) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1994.tb08222.x · Cited by 100
Observation of blood flow E.M.F. in externally applied strong magnetic field by surface electrodes
Togawa, T., Okai, O., & Oshima, M. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474505 · Cited by 93 · cited 1×
“However, afterwards, these changes were explained by the presence of the electromotive force (EMF) induced by blood flow in a static magnetic field, which is proportional to the quantity [32, 33].”
MR Safety and the American College of Radiology White Paper
Shellock, F. G., & Crues, J. V. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781349 · Cited by 90 · cited 1×
“This information is readily available to MR healthcare professionals, though it requires heightened awareness by the MR community to continually review and update their policies and procedures pertaining to MR safety based on the information in the relevant medical literature [11].”
BackgroundBiological Effects of Radiofrequency Radiation: Concepts and Criteria
Michaelson, S. M. (1991) · Health Physics · doi:10.1097/00004032-199107000-00001 · Cited by 89
INFLUENCE OF STRONG MAGNETIC FIELDS ON THE ELECTROCARDIOGRAM OF SQUIRREL MONKEYS (SAIMIRI SCIUREUS).
BEISCHER, D. E., & Knepton, J. C. (1964) · PubMed · Cited by 84
PHYSIOLOGIC EFFECTS OF INTENSE MR IMAGING GRADIENT FIELDS
BOURLAND, J. D., Nyenhuis, J. A., & Schaefer, D. J. (1999) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00564-7 · Cited by 82 · cited 1×
“[55,57] also found the mean threshold for magnetic stimulation of respiration and for gradientinduced cardiac stimulation in dogs.”
BackgroundOn the thermoregulatory consequences of NMR imaging
Adair, E. R., & Berglund, L. G. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)91042-8 · Cited by 75
Handbook of Biomedical Engineering
(1988) · Elsevier eBooks · doi:10.1016/b978-0-124-15145-1.x5001-4 · Cited by 70
Principles of Nerve and Heart Excitation by Time‐varying Magnetic Fields
REILLY, J. P. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49600.x · Cited by 70 · cited 2×
“Reilly applied his electrode numerical stimulation models to determine gradient-induced nerve [49] and cardiac stimulation thresholds [50,51], and predicted electric field amplitudes required for stimulation as a function of waveform (pulse duration, waveshape, and pulse train length).”
BackgroundMethodShellock, F. G., Schaefer, D. J., & Crues, J. V. (1989) · British Journal of Radiology · doi:10.1259/0007-1285-62-742-904 · Cited by 69
Magnetic field excitation of peripheral nerves and the heart: a comparison of thresholds
Reilly, J. P. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446087 · Cited by 67 · cited 1×
“Reilly applied his electrode numerical stimulation models to determine gradient-induced nerve [49] and cardiac stimulation thresholds [50,51], and predicted electric field amplitudes required for stimulation as a function of waveform (pulse duration, waveshape, and pulse train length).”
MethodShellock, F. G., Schaefer, D., & Kanal, E. (1994) · Radiology · doi:10.1148/radiology.192.3.8058962 · Cited by 63
Corneal temperature changes induced by high-field-strength MR imaging with a head coil.
Shellock, F. G., & Crues, J. V. (1988) · Radiology · doi:10.1148/radiology.167.3.3363146 · Cited by 57
Lin, J. C.-J. (2009) · Advances in electromagnetic fields in living systems · doi:10.1007/978-0-387-92736-7 · Cited by 54
Thermal Responses in Human Subjects Exposed to Magnetic Resonance Imaginga
Shellock, F. G. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49615.x · Cited by 40 · cited 2×
“Therefore, the data obtained in experiments with animals cannot strictly predict thermoregulatory or other physiological changes in human subjects exposed to RF radiation during MR examinations [69,72,73].”
BackgroundHeating of the scrotum by high-field-strength MR imaging.
Shellock, F. G., Rothman, B. J., & Sarti, D. A. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.154.6.2110733 · Cited by 36 · cited 1×
“A study [88] measured the scrotal skin temperatures in volunteers exposed to an MRI procedure at whole-body averaged SAR of 1.”
Adair, E. R., & Berglund, L. G. (1989) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(89)90321-4 · Cited by 34 · cited 1×
“Studies have demonstrated that RF radiationinduced heating may have detrimental effects on testicular functions if the scrotal or testicular tissue temperature exceeds 38°C [76].”
BackgroundPhysiologic changes during high field strength MR imaging
Dk, K., Tw, M., Erickson, J., Plewes, D. B., & Simon, J. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.6.1215 · Cited by 26
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
La Gioia, A., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 297
Biological Effects and Safety in Magnetic Resonance Imaging: A Review
Hartwig, V., Giovannetti, G., Vanello, N., Lombardi, M., Landini, L., & Simi, S. (2009) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph6061778 · Cited by 234
“size, the anatomical features and the sensitivity of the tissues [11].”
BackgroundInfluentialStimuli-responsive liposomal nanoformulations in cancer therapy: Pre-clinical & clinical approaches
Ashrafizadeh, M., Delfi, M., Zarrabi, A., Bigham, A., Sharifi, E., Rabiee, N., Paiva-Santos, A. C., Kumar, A. P., Tan, S. C., Hushmandi, K., et al. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.08.001 · Cited by 225
Plewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 220
“Furthermore, MRI does all of this in a noninvasive manner, which permits safe repeated scans with no known harm (26) when used within welldefined technical constraints (27).”
Background
Metadata
- Authors
- Formica, D., & Silvestri, S.
- Venue
- BioMedical Engineering OnLine
- Published
- 2004-04-22
- Volume
- 3
- Issue
- 1
- Pages
- 11-11
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2153292125
- Cited by
- 173
- References
- 46
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.