Towards treatment planning and treatment of deep-seated solid tumors by electrochemotherapy
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background: Electrochemotherapy treats tumors by combining specific chemotherapeutic drugs with an intracellular target and electric pulses, which increases drug uptake into the tumor cells. Electrochemotherapy has been successfully used for treatment of easily accessible superficial tumor nodules. In this paper, we present the first case of deep-seated tumor electrochemotherapy based on numerical treatment planning. Methods: The aim of our study was to treat a melanoma metastasis in the thigh of a patient. Treatment planning for electrode positioning and electrical pulse parameters was performed for two different electrode configurations: one with four and another with five long needle electrodes. During the procedure, the four electrode treatment plan was adopted and the patient was treated accordingly by electrochemotherapy with bleomycin. The response to treatment was clinically and radiographically evaluated. Due to a partial response of the treated tumor, the metastasis was surgically removed after 2 months and pathological analysis was performed. Results: A partial response of the tumor to electrochemotherapy was obtained. Histologically, the metastasis showed partial necrosis due to electrochemotherapy, estimated to represent 40-50% of the tumor. Based on the data obtained, we re-evaluated the electrical treatment parameters in order to correlate the treatment plan with the clinical response. Electrode positions in the numerical model were updated according to the actual positions during treatment. We compared the maximum value of the measured electric current with the current predicted by the model and good agreement was obtained. Finally, tumor coverage with an electric field above the reversible threshold was recalculated and determined to be approximately 94%. Therefore, according to the calculations, a small volume of tumor cells remained viable after electrochemotherapy, and these were sufficient for tumor regrowth. Conclusions: In this, the first reported clinical case, deep-seated melanoma metastasis in the thigh of the patient was treated by electrochemotherapy, according to a treatment plan obtained by numerical modeling and optimization. Although only a partial response was obtained, the presented work demonstrates that treatment of deep-seated tumor nodules by electrochemotherapy is feasible and sets the ground for numerical treatment planning-based electrochemotherapy. Trial registration: EudraCT:2008-008290-54
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marty, M., Sersa, G., Garbay, J. R., Gehl, J., Collins, C. G., Snoj, M., Billard, V., Geertsen, P. F., Larkin, J. O., Miklavcic, D., et al. (2006) · European Journal of Cancer Supplements · doi:10.1016/j.ejcsup.2006.08.002 · Cited by 908
Self-citationElectrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 716 · cited 3×
“All conductivity values were chosen according to previous measurements of tumor and tissue conductivity and models of subcutaneous tumor and skin electroporation [12-14].”
BackgroundMethodMir, L. M., Gehl, J., Sersa, G., Collins, C. G., Garbay, J.-R., Billard, V., Geertsen, P. F., Rudolf, Z., O’Sullivan, G. C., & Marty, M. (2006) · European Journal of Cancer Supplements · doi:10.1016/j.ejcsup.2006.08.003 · Cited by 610 · cited 1×
“Drug doses needed for treatment are provided in the published Standard Operating Procedures [ 5 ].”
MethodSelf-citationGothelf, A., Mir, L. M., & Gehl, J. (2003) · Cancer Treatment Reviews · doi:10.1016/s0305-7372(03)00073-2 · Cited by 549 · cited 1×
“drug choice, distribution and concentration in the tumors, in addition to adequate electric pulse parameter selection and pulse delivery leading to cell membrane electroporation of the tumor tissue [1-4].”
BackgroundElectrochemotherapy in treatment of tumours
Sersa, G., Miklavcic, D., Cemazar, M., Rudolf, Z., Pucihar, G., & Snoj, M. (2008) · European Journal of Surgical Oncology (EJSO) · doi:10.1016/j.ejso.2007.05.016 · Cited by 459 · cited 2×
“drug choice, distribution and concentration in the tumors, in addition to adequate electric pulse parameter selection and pulse delivery leading to cell membrane electroporation of the tumor tissue [1-4].”
BackgroundSelf-citationMiklavčič, D., Šemrov, D., Mekid, H., & Mir, L. M. (2000) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(00)00101-x · Cited by 366 · cited 1×
“In our post-treatment model, tissue electroporation thresholds for muscle and tumor were taken from previous studies in which these thresholds were determined by comparing in vivo measurements and numerical modeling of electroporation of different tissues [14,23,24].”
MethodCampana, L. G., Mocellin, S., Basso, M., Puccetti, O., De Salvo, G. L., Chiarion-Sileni, V., Vecchiato, A., Corti, L., Rossi, C. R., & Nitti, D. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-008-0204-8 · Cited by 291 · cited 1×
“The Cliniporator Vitae device is a pulse generator with 6 independently controlled and electrically insulated outputs each providing up to 3000 V, max current 50 A, delivering 8 rectangular electrical pulses (rise time 1 μs) of 100 μs duration at a pulse repetition frequency of 4 Hz [17].”
MethodEffect of Cell Electroporation on the Conductivity of a Cell Suspension
Pavlin, M., Kandušer, M., Reberšek, M., Pucihar, G., Hart, F. X., Magjarevićcacute;, R., & Miklavčič, D. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.048975 · Cited by 290 · cited 1×
“This assumption was already considered both theoretically and practically in previous studies and can be considered as justified [25-27].”
ResultSequential Finite Element Model of Tissue Electropermeabilization
Sel, D., Cukjati, D., Batiuskaite, D., Slivnik, T., Mir, L. M., & Miklavcic, D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845212 · Cited by 284 · cited 1×
“All clinically relevant tissue structures (tumor, muscle, adipose tissue) were delineated and used to construct 3D geometry objects in the numerical computing environment Matlab (Mathworks, USA) by the planar contour method as previously described by [11] (Figure 2).”
MethodSelf-citationIvorra, A., Al-Sakere, B., Rubinsky, B., & Mir, L. M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/019 · Cited by 217
Cited by
Antitumor effectiveness of electrochemotherapy: A systematic review and meta-analysis
Mali, B., Jarm, T., Snoj, M., Sersa, G., & Miklavcic, D. (2013) · European Journal of Surgical Oncology (EJSO) · doi:10.1016/j.ejso.2012.08.016 · Cited by 353
Self-citationChun, K.-R. J., Miklavčič, D., Vlachos, K., Bordignon, S., Scherr, D., Jais, P., & Schmidt, B. (2024) · Europace · doi:10.1093/europace/euae134 · Cited by 254
Miklavčič, D., Serša, G., Brecelj, E., Gehl, J., Soden, D., Bianchi, G., Ruggieri, P., Rossi, C. R., Campana, L. G., & Jarm, T. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0991-8 · Cited by 229
“This concept has already been successfully used in a clinical case [20, 46] and is being further developed.”
MethodAntivascular effects of electrochemotherapy: implications in treatment of bleeding metastases
Jarm, T., Cemazar, M., Miklavcic, D., & Sersa, G. (2010) · Expert Review of Anticancer Therapy · doi:10.1586/era.10.43 · Cited by 224
Self-citationCalvet, C. Y., Famin, D., André, F. M., & Mir, L. M. (2014) · OncoImmunology · doi:10.4161/onci.28131 · Cited by 223
Electrochemotherapy: A New Technological Approach in Treatment of Metastases in the Liver
Edhemovic, I., Gadzijev, E. M., Brecelj, E., Miklavcic, D., Kos, B., Zupanic, A., Mali, B., Jarm, T., Pavliha, D., Marcan, M., et al. (2011) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500224 · Cited by 182
Self-citationSano, M. B., Neal, R. E., Garcia, P. A., Gerber, D., Robertson, J., & Davalos, R. V. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-83 · Cited by 117
“[35,46], reaching a final conductivity of 0.”
Metadata
- Authors
- Miklavcic, D., Snoj, M., Zupanic, A., Kos, B., Cemazar, M., Kropivnik, M., Bracko, M., Pecnik, T., Gadzijev, E., & Sersa, G.
- Venue
- BioMedical Engineering OnLine
- Published
- 2010-02-23
- Volume
- 9
- Issue
- 1
- Pages
- 10-10
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2124148893
- Cited by
- 198
- References
- 19
- FWCI
- 13.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.