CoChat

Psychometric properties of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25), Japanese version

Open access
Suzukamo, Yoshimi, Oshika, Tetsuro, Yuzawa, Mitsuko, Tokuda, Yoshihiro, Tomidokoro, Atsuo, Oki, Kotaro, Mangione, Carol M, Green, Joseph, Fukuhara, Shunichi · 2005 · Health and Quality of Life Outcomes
Cited by 212

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Background: The importance of evaluating the outcomes of health care from the standpoint of the patient is now widely recognized. The purpose of this study is to develop and test a Japanese version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). Methods: A Japanese version was developed with a previously standardized method. The questionnaire and optional items were completed by 245 patients with cataracts, glaucoma, or age-related macular degeneration, by 110 others before and after cataract surgery, and by a reference group (n = 31). We computed rates of missing data, measured reproducibility and internal consistency reliability, and tested for convergent and discriminant validity, concurrent validity, known-groups validity, factor structure, and responsiveness to change. Results: Based on information from the participants, some items were changed to 2-step items (asking if an activity was done, and if it was done, then asking how difficult it was). The near-vision and distance-vision subscales each had 1 item that was endorsed by very few participants, so these items were replaced with items that were optional in the English version. For example, more than 60% of participants did not drive, so the driving question was excluded. Reliability and validity were adequate for all subscales except driving, ocular pain, color vision, and peripheral vision. With cataract surgery, most scores improved by at least 20 points. Conclusion: With minor modifications from the English version, the Japanese NEI VFQ-25 can give reliable, valid, responsive data on vision-related quality of life, for group-level comparisons or for tracking therapeutic outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1477-7525-3-65

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Metadata

Authors
Suzukamo, Y., Oshika, T., Yuzawa, M., Tokuda, Y., Tomidokoro, A., Oki, K., Mangione, C. M., Green, J., & Fukuhara, S.
Venue
Health and Quality of Life Outcomes
Published
2005-10-26
Volume
3
Issue
1
Pages
65-65
ISSN
1477-7525 (ISSN-L)
OpenAlex
W2153132577
Cited by
212
References
34
FWCI
4.14
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Psychometric properties of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25), Japanese version. https://app.cochat.ai/papers/10.1186/1477-7525-3-65
The paper
Suzukamo, Y., Oshika, T., Yuzawa, M., Tokuda, Y., Tomidokoro, A., Oki, K., Mangione, C. M., Green, J., & Fukuhara, S. (2005). Psychometric properties of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25), Japanese version. Health and Quality of Life Outcomes. https://doi.org/10.1186/1477-7525-3-65

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.