Nanomechanical properties of α-synuclein amyloid fibrils: a comparative study by nanoindentation, harmonic force microscopy, and Peakforce QNM
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We report on the use of three different atomic force spectroscopy modalities to determine the nanomechanical properties of amyloid fibrils of the human α-synuclein protein. α-Synuclein forms fibrillar nanostructures of approximately 10 nm diameter and lengths ranging from 100 nm to several microns, which have been associated with Parkinson's disease. Atomic force microscopy (AFM) has been used to image the morphology of these protein fibrils deposited on a flat surface. For nanomechanical measurements, we used single-point nanoindentation, in which the AFM tip as the indenter is moved vertically to the fibril surface and back while the force is being recorded. We also used two recently developed AFM surface property mapping techniques: Harmonic force microscopy (HarmoniX) and Peakforce QNM. These modalities allow extraction of mechanical parameters of the surface with a lateral resolution and speed comparable to tapping-mode AFM imaging. Based on this phenomenological study, the elastic moduli of the α-synuclein fibrils determined using these three different modalities are within the range 1.3-2.1 GPa. We discuss the relative merits of these three methods for the determination of the elastic properties of protein fibrils, particularly considering the differences and difficulties of each method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein folding and misfolding
Dobson, C. M. (2003) · Nature · doi:10.1038/nature02261 · Cited by 4,791 · cited 2×
“The reason for this spread, besides the previously mentioned errors, has been related to heterogeneity in the internal packing of amyloids [1,16,38].”
Background
Cited by
Dokukin, M. E., & Sokolov, I. (2012) · Langmuir · doi:10.1021/la302706b · Cited by 385
Imaging living cells surface and quantifying its properties at high resolution using AFM in QI™ mode
Chopinet, L., Formosa, C., Rols, M. P., Duval, R. E., & Dague, E. (2013) · Micron · doi:10.1016/j.micron.2013.02.003 · Cited by 200
Measurement of intrinsic properties of amyloid fibrils by the peak force QNM method
Adamcik, J., Lara, C., Usov, I., Jeong, J. S., Ruggeri, F. S., Dietler, G., Lashuel, H. A., Hamley, I. W., & Mezzenga, R. (2012) · Nanoscale · doi:10.1039/c2nr30768e · Cited by 198
Tan, J.-C., Saines, P. J., Bithell, E. G., & Cheetham, A. K. (2012) · ACS Nano · doi:10.1021/nn204054k · Cited by 183
Saar-Dover, R., Bitler, A., Nezer, R., Shmuel-Galia, L., Firon, A., Shimoni, E., Trieu-Cuot, P., & Shai, Y. (2012) · PLoS Pathogens · doi:10.1371/journal.ppat.1002891 · Cited by 164
“We also characterized the surface rigidity of non-treated WT, dltA mutant and dltA complemented strains by PeakForce QNM, which is based on a force-volume approach, and determination of the average value of DMT-modulus [34,35].”
Method
Metadata
- Authors
- Sweers, K., van der Werf, K., Bennink, M., & Subramaniam, V.
- Venue
- Nanoscale Research Letters
- Published
- 2011-03-30
- Volume
- 6
- Issue
- 1
- Pages
- 270-270
- ISSN
- 1556-276X (ISSN-L)
- OpenAlex
- W2126333524
- Cited by
- 175
- References
- 1
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.