Nanomechanical properties of α-synuclein amyloid fibrils: a comparative study by nanoindentation, harmonic force microscopy, and Peakforce QNM
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
We report on the use of three different atomic force spectroscopy modalities to determine the nanomechanical properties of amyloid fibrils of the human α-synuclein protein. α-Synuclein forms fibrillar nanostructures of approximately 10 nm diameter and lengths ranging from 100 nm to several microns, which have been associated with Parkinson's disease. Atomic force microscopy (AFM) has been used to image the morphology of these protein fibrils deposited on a flat surface. For nanomechanical measurements, we used single-point nanoindentation, in which the AFM tip as the indenter is moved vertically to the fibril surface and back while the force is being recorded. We also used two recently developed AFM surface property mapping techniques: Harmonic force microscopy (HarmoniX) and Peakforce QNM. These modalities allow extraction of mechanical parameters of the surface with a lateral resolution and speed comparable to tapping-mode AFM imaging. Based on this phenomenological study, the elastic moduli of the α-synuclein fibrils determined using these three different modalities are within the range 1.3-2.1 GPa. We discuss the relative merits of these three methods for the determination of the elastic properties of protein fibrils, particularly considering the differences and difficulties of each method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein folding and misfolding
Dobson, C. M. (2003) · Nature · doi:10.1038/nature02261 · Cited by 4,791 · cited 2×
“The reason for this spread, besides the previously mentioned errors, has been related to heterogeneity in the internal packing of amyloids [1,16,38].”
BackgroundUeber die Berührung fester elastischer Körper.
Hertz, H. (1882) · crll · doi:10.1515/crll.1882.92.156 · Cited by 4,789
Effect of contact deformations on the adhesion of particles
Derjaguin, B. V., Muller, V. M., & Toporov, Y. P. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90018-1 · Cited by 4,589
Alpha-synuclein and neurodegenerative diseases
Goedert, M. (2001) · Nature Reviews Neuroscience · doi:10.1038/35081564 · Cited by 1,408 · cited 1×
“a-Synuclein amyloid fibrils are found in the brains of Parkinson’s disease patients as components of larger plaques called Lewy bodies [5,6].”
BackgroundEnergy dissipation in tapping-mode atomic force microscopy
Cleveland, J. P., Anczykowski, B., Schmid, A. E., & Elings, V. B. (1998) · Applied Physics Letters · doi:10.1063/1.121434 · Cited by 881
Role of Intermolecular Forces in Defining Material Properties of Protein Nanofibrils
Knowles, T. P., Fitzpatrick, A. W., Meehan, S., Mott, H. R., Vendruscolo, M., Dobson, C. M., & Welland, M. E. (2007) · Science · doi:10.1126/science.1150057 · Cited by 782 · cited 2×
“Mechanical properties such as stiffness, rigidity, resistance to breakage or adhesive properties of these fibrils or individual monomers are interesting for the use of these fibrils as nanomaterials, for getting a better understanding of the physico-chemical properties of these fibrils, and to get more insight into th…”
BackgroundResultInfluentialCharacterization of the nanoscale properties of individual amyloid fibrils
Smith, J. F., Knowles, T. P. J., Dobson, C. M., MacPhee, C. E., & Welland, M. E. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604035103 · Cited by 640 · cited 1×
“Mechanical properties such as stiffness, rigidity, resistance to breakage or adhesive properties of these fibrils or individual monomers are interesting for the use of these fibrils as nanomaterials, for getting a better understanding of the physico-chemical properties of these fibrils, and to get more insight into th…”
BackgroundUnderstanding amyloid aggregation by statistical analysis of atomic force microscopy images
Adamcik, J., Jung, J.-M., Flakowski, J., De Los Rios, P., Dietler, G., & Mezzenga, R. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.59 · Cited by 619 · cited 1×
“Atomic force microscopy (AFM) has been primarily used as an imaging tool to determine morphological parameters such as height and length of amyloid fibrils, such as those formed from a-synuclein [2-4], insulin [7], and b-lactoglobulin [8].”
MethodDependence of α-Synuclein Aggregate Morphology on Solution Conditions
Hoyer, W., Antony, T., Cherny, D., Heim, G., Jovin, T. M., & Subramaniam, V. (2002) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)00775-1 · Cited by 565
Self-citationAmyloids: Not Only Pathological Agents but Also Ordered Nanomaterials
Cherny, I., & Gazit, E. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200703133 · Cited by 561 · cited 1×
“Mechanical properties such as stiffness, rigidity, resistance to breakage or adhesive properties of these fibrils or individual monomers are interesting for the use of these fibrils as nanomaterials, for getting a better understanding of the physico-chemical properties of these fibrils, and to get more insight into th…”
BackgroundAn atomic force microscope tip designed to measure time-varying nanomechanical forces
Sahin, O., Magonov, S., Su, C., Quate, C. F., & Solgaard, O. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.226 · Cited by 481 · cited 2×
“The higher harmonic vibrations of the cantilever excited by these material properties can provide more information, but they are heavily suppressed and are difficult to measure [21,24].”
BackgroundShults, C. W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509567103 · Cited by 476
Nanostructured films from hierarchical self-assembly of amyloidogenic proteins
Knowles, T. P. J., Oppenheim, T. W., Buell, A. K., Chirgadze, D. Y., & Welland, M. E. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.26 · Cited by 391 · cited 13×
“2 GPa) [37], and potentially reflect the differences in experimental conditions.”
BackgroundInfluentialRosa-Zeiser, A., Weilandt, E., Hild, S., & Marti, O. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/11/020 · Cited by 341
Amyloidogenic Self-Assembly of Insulin Aggregates Probed by High Resolution Atomic Force Microscopy
Jansen, R., Dzwolak, W., & Winter, R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.048843 · Cited by 270 · cited 1×
“Atomic force microscopy (AFM) has been primarily used as an imaging tool to determine morphological parameters such as height and length of amyloid fibrils, such as those formed from a-synuclein [2-4], insulin [7], and b-lactoglobulin [8].”
MethodBurnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Cook, S. M., Lang, K. M., Chynoweth, K. M., Wigton, M., Simmonds, R. W., & Schäffer, T. E. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/9/010 · Cited by 186 · cited 2×
“Using the law of propagation of errors, we estimate that this systematic error combined with the above-mentioned and the previously described 2% error in the deflection sensitivity measurements [34] yields an uncertainty of approximately 39% of the average measured value.”
BackgroundŞahin, Ö., & Erina, N. A. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/44/445717 · Cited by 175 · cited 2×
“HarmoniX has been applied to both polymers and biological features, for example, DNA [25,26].”
MethodDeformation and Fracture Behaviour of Polymers
(2001) · Engineering Materials · doi:10.1007/978-3-662-04556-5 · Cited by 174
Cantilever spring constant calibration using laser Doppler vibrometry
Ohler, B. (2007) · Review of Scientific Instruments · doi:10.1063/1.2743272 · Cited by 173 · cited 3×
“In this study, cantilevers were calibrated with the thermal noise method, which has an associated average error of 5% [33].”
BackgroundMethodDetermination of protein structural flexibility by microsecond force spectroscopy
Dong, M., Husale, S., & Şahin, Ö. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.156 · Cited by 169 · cited 2×
“HarmoniX has been applied to both polymers and biological features, for example, DNA [25,26].”
MethodGuo, S., & Akhremitchev, B. B. (2006) · Biomacromolecules · doi:10.1021/bm0600724 · Cited by 153 · cited 7×
“The radius of the tip in indentation studies is often determined by scanning electron microscopy [16] after the indentation experiments where the tip shape could be influenced by wear [30].”
BackgroundMethodInfluentialDetermination of the elastic modulus of native collagen fibrils via radial indentation
Heim, A. J., Matthews, W. G., & Koob, T. J. (2006) · Applied Physics Letters · doi:10.1063/1.2367660 · Cited by 142 · cited 2×
“AFM nanoindentation has been performed on different biological substrates such as collagen [15], insulin fibrils, and crystals [16], but also on different polymeric materials, such as fibrils used for biodegradable scaffolds [17].”
Backgroundvan Raaij, M. E., Segers‐Nolten, I. M. J., & Subramaniam, V. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.090449 · Cited by 128 · cited 4×
“Using SPIP software (Image Metrology A/S, Lyngby, Denmark), a trace was drawn on top of the fibril to determine the average height from the height images or modulus of elasticity from the stiffness maps of the individual fibrils, according to the procedure described in [4].”
BackgroundMethodInfluentialSelf-citationCalibration of silicon atomic force microscope cantilevers
Gibson, C. T., Smith, D. A., & Roberts, C. J. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/2/009 · Cited by 114 · cited 1×
“There are a number of techniques available to determine the spring constant, each with their own uncertainties [33-35].”
BackgroundFinite Sample Thickness Effects on Elasticity Determination Using Atomic Force Microscopy
Akhremitchev, B. B., & Walker, G. C. (1999) · Langmuir · doi:10.1021/la980585z · Cited by 109 · cited 3×
“The typical size scales of the fibrils give rise to finite sample thickness effects [16,36].”
BackgroundMethodNanoscale structures and mechanics of barnacle cement
Sullan, R. M. A., Gunari, N., Tanur, A. E., Chan, Y., Dickinson, G. H., Orihuela, B., Rittschof, D., & Walker, G. C. (2009) · Biofouling · doi:10.1080/08927010802688095 · Cited by 99 · cited 3×
“From the point of contact the modulus of elasticity values for the following 2 nm were averaged (20% indentation [12]).”
BackgroundNanoindentation study of nanofibers
Tan, E. P. S., & Lim, C. T. (2005) · Applied Physics Letters · doi:10.1063/1.2051802 · Cited by 96 · cited 1×
“AFM nanoindentation has been performed on different biological substrates such as collagen [15], insulin fibrils, and crystals [16], but also on different polymeric materials, such as fibrils used for biodegradable scaffolds [17].”
BackgroundPaparcone, R., Keten, S., & Buehler, M. J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.11.026 · Cited by 92
α-Synuclein Misfolding: Single Molecule AFM Force Spectroscopy Study
Yu, J., Málková, Š., & Lyubchenko, Y. L. (2008) · Journal of Molecular Biology · doi:10.1016/j.jmb.2008.10.006 · Cited by 84 · cited 1×
“Mechanical properties such as stiffness, rigidity, resistance to breakage or adhesive properties of these fibrils or individual monomers are interesting for the use of these fibrils as nanomaterials, for getting a better understanding of the physico-chemical properties of these fibrils, and to get more insight into th…”
BackgroundAtomic force microscopy spring constant determination in viscous liquids
Pirzer, T., & Hugel, T. (2009) · Review of Scientific Instruments · doi:10.1063/1.3100258 · Cited by 74 · cited 1×
“These hydrodynamic forces acting on the cantilever are frequency-dependent [27,28].”
BackgroundZenhausern, F., Adrian, M., ten Heggeler-Bordier, B., Eng, L. M., & Descouts, P. (1992) · Scanning · doi:10.1002/sca.4950140405 · Cited by 61 · cited 2×
“First, from the AFM height images of protein fibrils the tip radius was derived from the fibril height-towidth ratio based on tip-sample convolution [21,31].”
MethodŞahin, Ö. (2007) · Review of Scientific Instruments · doi:10.1063/1.2801009 · Cited by 59 · cited 2×
“The system was calibrated with a reference sample (model PS-LDPE, Veeco, Santa Barbara, CA, USA) [20].”
BackgroundMethodCarbon nanotubes: A promising standard for quantitative evaluation of AFM tip apex geometry
Wang, Y., & Chen, X. (2006) · Ultramicroscopy · doi:10.1016/j.ultramic.2006.08.004 · Cited by 53
Deformation and fracture behavior of polymers
Grellmann, W., & Seidler, S. (2001) · Springer eBooks · Cited by 39
AFM-based force spectroscopy measurements of mature amyloid fibrils of the peptide glucagon
Dong, M., Hovgaard, M. B., Mamdouh, W., Xu, S., Otzen, D. E., & Besenbacher, F. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/38/384013 · Cited by 39 · cited 1×
“Mechanical properties such as stiffness, rigidity, resistance to breakage or adhesive properties of these fibrils or individual monomers are interesting for the use of these fibrils as nanomaterials, for getting a better understanding of the physico-chemical properties of these fibrils, and to get more insight into th…”
BackgroundTamayo, J., Calleja, M., Ramos, D., & Mertens, J. (2007) · Physical Review B · doi:10.1103/physrevb.76.180201 · Cited by 27 · cited 1×
“These hydrodynamic forces acting on the cantilever are frequency-dependent [27,28].”
BackgroundQuantitative Characterization of Protein Nanostructures Using Atomic Force Microscopy
Segers‐Nolten, I. M. J., van der Werf, K., van Raaij, M. E., & Subramaniam, V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353874 · Cited by 18
Self-citation
Cited by
Dokukin, M. E., & Sokolov, I. (2012) · Langmuir · doi:10.1021/la302706b · Cited by 385
Structure, function and toxicity of alpha‐synuclein: the Bermuda triangle in synucleinopathies
Villar‐Piqué, A., Lopes da Fonseca, T., & Outeiro, T. F. (2016) · Journal of Neurochemistry · doi:10.1111/jnc.13249 · Cited by 218
“Twisted and untwisted fibrils, curved and straight fibrils, periodic and non-periodic fibrils have all been reported, with fibril widths ranging from 6 to 18 nm and fibril lengths ranging from 0.1 lm to more than 5 lm (van Raaij et al. 2008; Sweers et al. 2011, 2012a,b; Bousset et al. 2013).”
BackgroundInfluentialShin, H., Park, J., Han, S., Sastry, A. M., & Lu, W. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.11.120 · Cited by 217
Imaging living cells surface and quantifying its properties at high resolution using AFM in QI™ mode
Chopinet, L., Formosa, C., Rols, M. P., Duval, R. E., & Dague, E. (2013) · Micron · doi:10.1016/j.micron.2013.02.003 · Cited by 200
Measurement of intrinsic properties of amyloid fibrils by the peak force QNM method
Adamcik, J., Lara, C., Usov, I., Jeong, J. S., Ruggeri, F. S., Dietler, G., Lashuel, H. A., Hamley, I. W., & Mezzenga, R. (2012) · Nanoscale · doi:10.1039/c2nr30768e · Cited by 198
Metadata
- Authors
- Sweers, K., van der Werf, K., Bennink, M., & Subramaniam, V.
- Venue
- Nanoscale Research Letters
- Published
- 2011-03-30
- Volume
- 6
- Issue
- 1
- Pages
- 270-270
- ISSN
- 1556-276X (ISSN-L)
- OpenAlex
- W2126333524
- Cited by
- 175
- References
- 38
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.