The DOI matches its Crossref record.
Assessment of cytotoxicity of (N-isopropyl acrylamide) and Poly(N-isopropyl acrylamide)-coated surfaces
Open accessAbstract
Poly(N-isopropyl acrylamide) (pNIPAM) is one of the most popular stimulus-responsive polymers for research. It is especially of great interest in the field of tissue engineering. While it is known that the NIPAM monomer is toxic, there is little conclusive research on the cytotoxicity of the polymer. In this work, the relative biocompatibility of the NIPAM monomer, pNIPAM, and pNIPAM-coated substrates prepared using different polymerization (free radical and plasma polymerization) and deposition (spin coating and plasma polymerization) techniques was evaluated using appropriate cytotoxicity tests (MTS, Live/Dead, plating efficiency). Four different mammalian cell types (endothelial, epithelial, smooth muscle, and fibroblasts) were used for the cytotoxicity testing. The pNIPAM-coated surfaces were evaluated for their thermoresponse and surface chemistry using X-ray photoelectron spectroscopy and goniometry. We found that while cell viability on pNIPAM surfaces decreases when compared to controls, the viability also seems to be deposition type dependent, with sol–gel based pNIPAM surfaces being the least biocompatible. Long term experiments proved that all pNIPAM-coated surfaces were not cytotoxic to the four cell types evaluated in a direct contact test. Plating efficiency experiments did not show cytotoxicity. Cellular sensitivity to pNIPAM and to the NIPAM monomer varied depending on cell type. Endothelial cells consistently showed decreased viability after 48 hours of exposure to pNIPAM extracts and were more sensitive than the other cell lines to impurities in the polymer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermoresponsive polymers and their biomedical application in tissue engineering – a review
Doberenz, F., Zeng, K., Willems, C., Zhang, K., & Groth, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02052g · Cited by 427
Thermo-sensitive polymers in medicine: A review
Zarrintaj, P., Jouyandeh, M., Ganjali, M. R., Hadavand, B. S., Mozafari, M., Sheiko, S. S., Vatankhah-Varnoosfaderani, M., Gutiérrez, T. J., & Saeb, M. R. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.05.024 · Cited by 288
Drug delivery based on stimuli-responsive injectable hydrogels for breast cancer therapy: A review
Xin, H., & Naficy, S. (2022) · Gels · doi:10.3390/gels8010045 · Cited by 83
Metadata
- Authors
- Cooperstein, M. A., & Canavan, H. E.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2013-08-07
- Volume
- 8
- Issue
- 1
- Pages
- 19-19
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W2112254361
- Cited by
- 205
- References
- 0
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of cytotoxicity of (N-isopropyl acrylamide) and Poly(N-isopropyl acrylamide)-coated surfaces. https://app.cochat.ai/papers/10.1186/1559-4106-8-19
- The paper
- Cooperstein, M. A., & Canavan, H. E. (2013). Assessment of cytotoxicity of (N-isopropyl acrylamide) and Poly(N-isopropyl acrylamide)-coated surfaces. Biointerphases. https://doi.org/10.1186/1559-4106-8-19
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.