Assessment of cytotoxicity of (N-isopropyl acrylamide) and Poly(N-isopropyl acrylamide)-coated surfaces
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Poly(N-isopropyl acrylamide) (pNIPAM) is one of the most popular stimulus-responsive polymers for research. It is especially of great interest in the field of tissue engineering. While it is known that the NIPAM monomer is toxic, there is little conclusive research on the cytotoxicity of the polymer. In this work, the relative biocompatibility of the NIPAM monomer, pNIPAM, and pNIPAM-coated substrates prepared using different polymerization (free radical and plasma polymerization) and deposition (spin coating and plasma polymerization) techniques was evaluated using appropriate cytotoxicity tests (MTS, Live/Dead, plating efficiency). Four different mammalian cell types (endothelial, epithelial, smooth muscle, and fibroblasts) were used for the cytotoxicity testing. The pNIPAM-coated surfaces were evaluated for their thermoresponse and surface chemistry using X-ray photoelectron spectroscopy and goniometry. We found that while cell viability on pNIPAM surfaces decreases when compared to controls, the viability also seems to be deposition type dependent, with sol–gel based pNIPAM surfaces being the least biocompatible. Long term experiments proved that all pNIPAM-coated surfaces were not cytotoxic to the four cell types evaluated in a direct contact test. Plating efficiency experiments did not show cytotoxicity. Cellular sensitivity to pNIPAM and to the NIPAM monomer varied depending on cell type. Endothelial cells consistently showed decreased viability after 48 hours of exposure to pNIPAM extracts and were more sensitive than the other cell lines to impurities in the polymer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385 · cited 1×
“PNIPAM is one of the most commonly used stimulusresponsive polymers for research [7,8].”
BackgroundNishida, K., Yamato, M., Hayashida, Y., Watanabe, K., Yamamoto, K., Adachi, E., Nagai, S., Kikuchi, A., Maeda, N., Watanabe, H., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040455 · Cited by 1,513 · cited 1×
“There is currently a great deal of research regarding the development of engineered tissues or devices using pNIPAM [9-12].”
BackgroundOkano, T., Yamada, N., Sakai, H., & Sakurai, Y. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271005 · Cited by 1,020 · cited 1×
“When the temperature is lowered to below pNIPAM’s lower critical solution temperature (LCST, 32°C), the polymer’s chains extend and cells detach in intact sheets [1,2].”
BackgroundMechanism of cell detachment from temperature-modulated, hydrophilic-hydrophobic polymer surfaces
Okano, T., Yamada, N., Okuhara, M., Sakai, H., & Sakurai, Y. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93257-e · Cited by 886
Thermosensitive water-soluble copolymers with doubly responsive reversibly interacting entities
Dimitrov, I., Trzebicka, B., Müller, A. H. E., Dworak, A., & Tsvetanov, C. B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.07.001 · Cited by 750 · cited 1×
“PNIPAM is one of the most commonly used stimulusresponsive polymers for research [7,8].”
BackgroundVihola, H., Laukkanen, A., Valtola, L., Tenhu, H., & Hirvonen, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.008 · Cited by 689 · cited 11×
“Free radical polymerization of NIPAM was adapted from Vihola et al [13].”
BackgroundMethodResultInfluentialCell sheet engineering for myocardial tissue reconstruction
Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00110-8 · Cited by 673
Cole, M. A., Voelcker, N. H., Thissen, H., & Griesser, H. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.026 · Cited by 454
Repair of impaired myocardium by means of implantation of engineered autologous myoblast sheets
Memon, I. A., Sawa, Y., Fukushima, N., Matsumiya, G., Miyagawa, S., Taketani, S., Sakakida, S. K., Kondoh, H., Aleshin, A. N., Shimizu, T., et al. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.07.023 · Cited by 325 · cited 1×
“There is currently a great deal of research regarding the development of engineered tissues or devices using pNIPAM [9-12].”
Background
Cited by
Thermoresponsive polymers and their biomedical application in tissue engineering – a review
Doberenz, F., Zeng, K., Willems, C., Zhang, K., & Groth, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02052g · Cited by 427
Thermo-sensitive polymers in medicine: A review
Zarrintaj, P., Jouyandeh, M., Ganjali, M. R., Hadavand, B. S., Mozafari, M., Sheiko, S. S., Vatankhah-Varnoosfaderani, M., Gutiérrez, T. J., & Saeb, M. R. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.05.024 · Cited by 288
Thermoresponsive polysaccharides and their thermoreversible physical hydrogel networks
Graham, S., Marina, P. F., & Blencowe, A. (2019) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2018.11.053 · Cited by 245
Cook, M. T., Haddow, P., Kirton, S. B., & McAuley, W. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008123 · Cited by 225
Nanogels As drug-delivery Systems: a Comprehensive Overview
Suhail, M., Rosenholm, J. M., Minhas, M. U., Badshah, S. F., Naeem, A., Khan, K. U., & Fahad, M. (2019) · Therapeutic Delivery · doi:10.4155/tde-2019-0010 · Cited by 210
Swimming Microrobots: Soft, Reconfigurable, and Smart
Medina‐Sánchez, M., Magdanz, V., Guix, M., Fomin, V. M., & Schmidt, O. G. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201707228 · Cited by 207
Patra, S., Roy, E., Karfa, P., Kumar, S., Madhuri, R., & Sharma, P. K. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b01786 · Cited by 160
RetractedDrug delivery based on stimuli-responsive injectable hydrogels for breast cancer therapy: A review
Xin, H., & Naficy, S. (2022) · Gels · doi:10.3390/gels8010045 · Cited by 83
Metadata
- Authors
- Cooperstein, M. A., & Canavan, H. E.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2013-08-07
- Volume
- 8
- Issue
- 1
- Pages
- 19-19
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W2112254361
- Cited by
- 205
- References
- 26
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.