CoChat

Contamination of human DNA samples with mouse DNA can lead to false detection of XMRV-like sequences

Open access
Oakes, Brendan, Tai, Albert K, Cingöz, Oya, Henefield, Madeleine H, Levine, Susan, Coffin, John M, Huber, Brigitte T · 2010 · Retrovirology
Cited by 133

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: In 2006, a novel gammaretrovirus, XMRV (xenotropic murine leukemia virus-related virus), was discovered in some prostate tumors. A more recent study indicated that this infectious retrovirus can be detected in 67% of patients suffering from chronic fatigue syndrome (CFS), but only very few healthy controls (4%). However, several groups have published to date that they could not identify XMRV RNA or DNA sequences in other cohorts of CFS patients, while another group detected murine leukemia virus (MLV)-like sequences in 87% of such patients, but only 7% of healthy controls. Since there is a high degree of similarity between XMRV and abundant endogenous MLV proviruses, it is important to distinguish contaminating mouse sequences from true infections. Results: DNA from the peripheral blood of 112 CFS patients and 36 healthy controls was tested for XMRV with two different PCR assays. A TaqMan qPCR assay specific for XMRV pol sequences was able to detect viral DNA from 2 XMRV-infected cells (~ 10-12 pg DNA) in up to 5 μg of human genomic DNA, but yielded negative results in the test of 600 ng genomic DNA from 100,000 peripheral blood cells of all samples tested. However, positive results were obtained with some of these samples, using a less specific nested PCR assay for a different XMRV sequence. DNA sequencing of the PCR products revealed a wide variety of virus-related sequences, some identical to those found in prostate cancer and CFS patients, others more closely related to known endogenous MLVs. However, all samples that tested positive for XMRV and/or MLV DNA were also positive for the highly abundant intracisternal A-type particle (IAP) long terminal repeat and most were positive for murine mitochondrial cytochrome oxidase sequences. No contamination was observed in any of the negative control samples, containing those with no DNA template, which were included in each assay. Conclusions: Mouse cells contain upwards of 100 copies each of endogenous MLV DNA. Even much less than one cell's worth of DNA can yield a detectable product using highly sensitive PCR technology. It is, therefore, vital that contamination by mouse DNA be monitored with adequately sensitive assays in all samples tested.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1742-4690-7-109

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

2 retracted

Show all 6 references

Cited by

See all 133

Metadata

Authors
Oakes, B., Tai, A. K., Cingöz, O., Henefield, M. H., Levine, S., Coffin, J. M., & Huber, B. T.
Venue
Retrovirology
Published
2010-12
Volume
7
Issue
1
Pages
109-109
ISSN
1742-4690 (ISSN-L)
OpenAlex
W2115733904
Cited by
133
References
6
FWCI
21.73
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contamination of human DNA samples with mouse DNA can lead to false detection of XMRV-like sequences. https://app.cochat.ai/papers/10.1186/1742-4690-7-109
The paper
Oakes, B., Tai, A. K., Cingöz, O., Henefield, M. H., Levine, S., Coffin, J. M., & Huber, B. T. (2010). Contamination of human DNA samples with mouse DNA can lead to false detection of XMRV-like sequences. Retrovirology. https://doi.org/10.1186/1742-4690-7-109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.