Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of hand kinematics using inertial and magnetic sensors

Open access
Kortier, Henk G, Sluiter, Victor I, Roetenberg, Daniel, Veltink, Peter H · 2014 · Journal of NeuroEngineering and Rehabilitation

Abstract

BACKGROUND: Assessment of hand kinematics is important when evaluating hand functioning. Major drawbacks of current sensing glove systems are lack of rotational observability in particular directions, labour intensive calibration methods which are sensitive to wear and lack of an absolute hand orientation estimate. METHODS: We propose an ambulatory system using inertial sensors that can be placed on the hand, fingers and thumb. It allows a full 3D reconstruction of all finger and thumb joints as well as the absolute orientation of the hand. The system was experimentally evaluated for the static accuracy, dynamic range and repeatability. RESULTS: The RMS position norm difference of the fingertip compared to an optical system was 5±0.5 mm (mean ± standard deviation) for flexion-extension and 12.4±3.0 mm for combined flexion-extension abduction-adduction movements of the index finger. The difference between index and thumb tips during a pinching movement was 6.5±2.1 mm. The dynamic range of the sensing system and filter was adequate to reconstruct full 80 degrees movements of the index finger performed at 116 times per minute, which was limited by the range of the gyroscope. Finally, the reliability study showed a mean range difference over five subjects of 1.1±0.4 degrees for a flat hand test and 1.8±0.6 degrees for a plastic mold clenching test, which is smaller than other reported data gloves. CONCLUSION: Compared to existing data gloves, this research showed that inertial and magnetic sensors are of interest for ambulatory analysis of the human hand and finger kinematics in terms of static accuracy, dynamic range and repeatability. It allows for estimation of multi-degree of freedom joint movements using low-cost sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-0003-11-70

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 173

Metadata

Authors
Kortier, H. G., Sluiter, V. I., Roetenberg, D., & Veltink, P. H.
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2014
Volume
11
Issue
1
Pages
70
ISSN
1743-0003 (ISSN-L)
OpenAlex
W2144794162
Cited by
173
References
1
FWCI
33.46
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of hand kinematics using inertial and magnetic sensors. https://app.cochat.ai/papers/10.1186/1743-0003-11-70
The paper
Kortier, H. G., Sluiter, V. I., Roetenberg, D., & Veltink, P. H. (2014). Assessment of hand kinematics using inertial and magnetic sensors. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-11-70

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.