Assessment of hand kinematics using inertial and magnetic sensors
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Assessment of hand kinematics is important when evaluating hand functioning. Major drawbacks of current sensing glove systems are lack of rotational observability in particular directions, labour intensive calibration methods which are sensitive to wear and lack of an absolute hand orientation estimate. METHODS: We propose an ambulatory system using inertial sensors that can be placed on the hand, fingers and thumb. It allows a full 3D reconstruction of all finger and thumb joints as well as the absolute orientation of the hand. The system was experimentally evaluated for the static accuracy, dynamic range and repeatability. RESULTS: The RMS position norm difference of the fingertip compared to an optical system was 5±0.5 mm (mean ± standard deviation) for flexion-extension and 12.4±3.0 mm for combined flexion-extension abduction-adduction movements of the index finger. The difference between index and thumb tips during a pinching movement was 6.5±2.1 mm. The dynamic range of the sensing system and filter was adequate to reconstruct full 80 degrees movements of the index finger performed at 116 times per minute, which was limited by the range of the gyroscope. Finally, the reliability study showed a mean range difference over five subjects of 1.1±0.4 degrees for a flat hand test and 1.8±0.6 degrees for a plastic mold clenching test, which is smaller than other reported data gloves. CONCLUSION: Compared to existing data gloves, this research showed that inertial and magnetic sensors are of interest for ambulatory analysis of the human hand and finger kinematics in terms of static accuracy, dynamic range and repeatability. It allows for estimation of multi-degree of freedom joint movements using low-cost sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“or are worn on the back of the hand, leaving sensation intact, but are bulky and impractical for users to wear on their own [14,15,16,17].”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558
Kuipers, J. B. (1999) · Princeton University Press eBooks · doi:10.1515/9780691211701 · Cited by 1,290
Survey of Nonlinear Attitude Estimation Methods
Crassidis, J. L., Markley, F. L., & Cheng, Y. (2007) · Journal of Guidance, Control, and Dynamics · doi:10.2514/1.22452 · Cited by 1,094
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
Vision-based hand pose estimation: A review
Erol, A., Bebis, G., Nicolescu, M., Boyle, R. D., & Twombly, X. (2007) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.10.012 · Cited by 866
A Survey of Glove-Based Systems and Their Applications
Dipietro, L., Sabatini, A. M., & Dario, P. (2008) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2008.923862 · Cited by 691
Clinical mechanics of the hand
Brand, P. W. (1985) · Medical Entomology and Zoology · Cited by 690
Zero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662
Kuipers, J. (2020) · Princeton University Press eBooks · doi:10.2307/j.ctvx5wc3k · Cited by 642
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Self-citationYun, X., & Bachmann, E. R. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886270 · Cited by 569
A New Mathematical Formulation for Strapdown Inertial Navigation
Bortz, J. (1971) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1971.310252 · Cited by 416
Model-based hand tracking using a hierarchical Bayesian filter
Stenger, B., Thayananthan, A., Torr, P. H. S., & Cipolla, R. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.189 · Cited by 415
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356
Self-citationAmbulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Roetenberg, D., Slycke, P. J., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889184 · Cited by 334
Self-citationGustafsson, F. (2013) · Cited by 327
Anthropometric data for describing the kinematics of the human hand
BUCHHOLZ, B., ARMSTRONG, T. J., & GOLDSTEIN, S. A. (1992) · Ergonomics · doi:10.1080/00140139208967812 · Cited by 246
Nenya: subtle and eyes-free mobile input with a magnetically-tracked finger ring
Ashbrook, D., Baudisch, P., & White, S. (2011) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1978942.1979238 · Cited by 231
Clinical mechanics of the hand
Helm, P. A. (1986) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(86)90081-x · Cited by 173
Gentner, R., & Claßen, J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.11.005 · Cited by 169
Evaluation of an instrumented glove for hand-movement acquisition
Dipietro, L., Sabatini, A. M., & Dario, P. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.03.0181 · Cited by 158
A low cost instrumented glove for extended monitoring and functional hand assessment
Simone, L. K., Sundarrajan, N., Luo, X., Jia, Y., & Kamper, D. G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.021 · Cited by 154 · cited 2×
“Simone et al [25], evaluated the “Shadow Monitor” which has a simpler approach and showed a comparable reliability.”
Quaternions and Rotation Sequences
Kuipers, J. (2012) · doi:10.7546/giq-1-2000-127-143 · Cited by 127
Evaluation of a fiber optic glove for semi-automated goniometric measurements
Wise, S., Gardner, W., Sabelman, E. E., Valainis, E., Wong, Y., Glass, K., DRACE, J. E., & Rosen, J. M. (1990) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1990.10.0411 · Cited by 126
Assessing assumptions in kinematic hand models: A review
Bullock, I. M., Borràs, J., & Dollar, A. M. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290879 · Cited by 108
A Goniometric Glove for Clinical Hand Assessment
WILLIAMS, N. W., Penrose, J., Caddy, C. M., BARNES, E., Hose, D. R., & HARLEY, P. (2000) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.1999.0360 · Cited by 86
A New Wearable Input Device: SCURRY
Kim, Y. S., Soh, B. S., & Lee, S. G. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.858736 · Cited by 81
The AcceleGlove: a whole-hand input device for virtual reality
Hernandez-Rebollar, J. L., Kyriakopoulos, N., & Lindeman, R. W. (2002) · ACM SIGGRAPH Conference Abstracts and Applications · doi:10.1145/1242073.1242272 · Cited by 75
Development of a Fingertip Glove Equipped with Magnetic Tracking Sensors
Fahn, C., & Sun, H. (2010) · Sensors · doi:10.3390/s100201119 · Cited by 48
Rowe, J. B., Friedman, N., Bachman, M., & Reinkensmeyer, D. J. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650397 · Cited by 27
Cited by
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
Computational neurorehabilitation: modeling plasticity and learning to predict recovery
Reinkensmeyer, D. J., Burdet, E., Casadio, M., Krakauer, J. W., Kwakkel, G., Lang, C. E., Swinnen, S. P., Ward, N. S., & Schweighofer, N. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0148-3 · Cited by 183
Edriss, S., Romagnoli, C., Caprioli, L., Zanela, A., Panichi, E., Campoli, F., Padua, E., Annino, G., & Bonaiuto, V. (2024) · Applied Sciences · doi:10.3390/app14031012 · Cited by 142
3D human gesture capturing and recognition by the IMMU-based data glove
Fang, B., Sun, F., Liu, H., & Liu, C. (2017) · Neurocomputing · doi:10.1016/j.neucom.2017.02.101 · Cited by 139
Yu, L., Xiong, D., Guo, L., & Wang, J. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.02.012 · Cited by 134
Metadata
- Authors
- Kortier, H. G., Sluiter, V. I., Roetenberg, D., & Veltink, P. H.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014
- Volume
- 11
- Issue
- 1
- Pages
- 70
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2144794162
- Cited by
- 173
- References
- 30
- FWCI
- 33.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.