Assessment of hand kinematics using inertial and magnetic sensors
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Assessment of hand kinematics is important when evaluating hand functioning. Major drawbacks of current sensing glove systems are lack of rotational observability in particular directions, labour intensive calibration methods which are sensitive to wear and lack of an absolute hand orientation estimate. METHODS: We propose an ambulatory system using inertial sensors that can be placed on the hand, fingers and thumb. It allows a full 3D reconstruction of all finger and thumb joints as well as the absolute orientation of the hand. The system was experimentally evaluated for the static accuracy, dynamic range and repeatability. RESULTS: The RMS position norm difference of the fingertip compared to an optical system was 5±0.5 mm (mean ± standard deviation) for flexion-extension and 12.4±3.0 mm for combined flexion-extension abduction-adduction movements of the index finger. The difference between index and thumb tips during a pinching movement was 6.5±2.1 mm. The dynamic range of the sensing system and filter was adequate to reconstruct full 80 degrees movements of the index finger performed at 116 times per minute, which was limited by the range of the gyroscope. Finally, the reliability study showed a mean range difference over five subjects of 1.1±0.4 degrees for a flat hand test and 1.8±0.6 degrees for a plastic mold clenching test, which is smaller than other reported data gloves. CONCLUSION: Compared to existing data gloves, this research showed that inertial and magnetic sensors are of interest for ambulatory analysis of the human hand and finger kinematics in terms of static accuracy, dynamic range and repeatability. It allows for estimation of multi-degree of freedom joint movements using low-cost sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“or are worn on the back of the hand, leaving sensation intact, but are bulky and impractical for users to wear on their own [14,15,16,17].”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558 · cited 2×
“Wu G, van der Helm FCT, Veeger HEJ, Makhsous M, van Roy P, Anglin C, Nagels J, Karduna AR, McQuade K, Wang X, Werner FW, Bucholz B: ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion–Part II: shoulder, elbow, wrist and hand.”
ResultKuipers, J. B. (1999) · Princeton University Press eBooks · doi:10.1515/9780691211701 · Cited by 1,290
Survey of Nonlinear Attitude Estimation Methods
Crassidis, J. L., Markley, F. L., & Cheng, Y. (2007) · Journal of Guidance, Control, and Dynamics · doi:10.2514/1.22452 · Cited by 1,094 · cited 2×
“We will use the multiplicative error quaternion method [13], where the filter operates on the error quaternion which can be expressed as a non-co nstrained vector.”
MethodQuaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887 · cited 2×
“This method has an excellent reputation in navigation purposes for airplanes and satellites [13] and, more recently, for MEMS based IMMS tracking as well [14-17].”
MethodResultVision-based hand pose estimation: A review
Erol, A., Bebis, G., Nicolescu, M., Boyle, R. D., & Twombly, X. (2007) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.10.012 · Cited by 866 · cited 1×
“In addition, occlusion of the hand-segments or markers result in a non-observable situation, inducing a poor estimate of th hand pose [1,2].”
BackgroundA Survey of Glove-Based Systems and Their Applications
Dipietro, L., Sabatini, A. M., & Dario, P. (2008) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2008.923862 · Cited by 691 · cited 1×
“Two popular sensingmethods are resistive-bend sensors and optical fiber sensors, with the latter one giving the highest accuracy (< 1 deg), [3].”
BackgroundClinical mechanics of the hand
Brand, P. W. (1985) · Medical Entomology and Zoology · Cited by 690
Zero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662 · cited 1×
“In order to reduce drifting errors, an additional zero velocity detector is implemented to detect no-movement situations in which the integrators are set to zero [20].”
MethodKuipers, J. (2020) · Princeton University Press eBooks · doi:10.2307/j.ctvx5wc3k · Cited by 642
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588 · cited 2×
“[8] is exploited to estimate the optimal absolute hand kinematics.”
BackgroundSelf-citation
Cited by
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
Computational neurorehabilitation: modeling plasticity and learning to predict recovery
Reinkensmeyer, D. J., Burdet, E., Casadio, M., Krakauer, J. W., Kwakkel, G., Lang, C. E., Swinnen, S. P., Ward, N. S., & Schweighofer, N. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0148-3 · Cited by 183
Edriss, S., Romagnoli, C., Caprioli, L., Zanela, A., Panichi, E., Campoli, F., Padua, E., Annino, G., & Bonaiuto, V. (2024) · Applied Sciences · doi:10.3390/app14031012 · Cited by 142
3D human gesture capturing and recognition by the IMMU-based data glove
Fang, B., Sun, F., Liu, H., & Liu, C. (2017) · Neurocomputing · doi:10.1016/j.neucom.2017.02.101 · Cited by 139
Yu, L., Xiong, D., Guo, L., & Wang, J. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.02.012 · Cited by 134
Metadata
- Authors
- Kortier, H. G., Sluiter, V. I., Roetenberg, D., & Veltink, P. H.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014
- Volume
- 11
- Issue
- 1
- Pages
- 70
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2144794162
- Cited by
- 173
- References
- 30
- FWCI
- 33.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.