Design considerations for a wearable monitor to measure finger posture
Open accessThe DOI matches its Crossref record.
Abstract
Background: Objective measures of hand function as individuals participate in home and community activities are needed in order to better plan and evaluate rehabilitation treatments. Traditional measures collected in the clinical setting are often not reflective of actual functional performance. Recent advances in technology, however, enable the development of a lightweight, comfortable data collection monitor to measure hand kinematics. Methods: This paper presents the design analysis of a wearable sensor glove with a specific focus on the sensors selected to measure bend. The most important requirement for the glove is easy donning and removal for individuals with significantly reduced range of motion in the hands and fingers. Additional requirements include comfort and durability, cost effectiveness, and measurement repeatability. These requirements eliminate existing measurement gloves from consideration. Glove construction is introduced, and the sensor selection and glove evaluation process are presented. Results: Evaluation of commercial bend sensors shows that although most are not appropriate for repeatable measurements of finger flexion, one has been successfully identified. A case study for sensor glove repeatability using the final glove configuration and sensors does show a high degree of repeatability in both the gripped and flat hand positions (average coefficient of variability = 2.96% and 0.10%, respectively). Conclusion: Measuring functional outcomes in a portable manner can provide a wealth of information important to clinicians for the evaluation and treatment of movement disorders in the hand and fingers. This device is an important step in that direction as both a research and an evaluation method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Feedback Control of Soft Robot Actuators via Commercial Flex Bend Sensors
Gerboni, G., Diodato, A., Ciuti, G., Cianchetti, M., & Menciassi, A. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2699677 · Cited by 220
Bundhoo, V., Haslam, E., Birch, B., & Park, E. J. (2009) · Robotica · doi:10.1017/s026357470800458x · Cited by 175
Resistive flex sensors: a survey
Saggio, G., Riillo, F., Sbernini, L., & Quitadamo, L. R. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/1/013001 · Cited by 175
Metadata
- Authors
- Simone, L. K., & Kamper, D. G.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2005-03-01
- Volume
- 2
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2099052740
- Cited by
- 108
- References
- 0
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design considerations for a wearable monitor to measure finger posture. https://app.cochat.ai/papers/10.1186/1743-0003-2-5
- The paper
- Simone, L. K., & Kamper, D. G. (2005). Design considerations for a wearable monitor to measure finger posture. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-2-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.