A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Recent technological advances in integrated circuits, wireless communications, and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices. A number of these devices can be integrated into a Wireless Body Area Network (WBAN), a new enabling technology for health monitoring. Methods: Using off-the-shelf wireless sensors we designed a prototype WBAN which features a standard ZigBee compliant radio and a common set of physiological, kinetic, and environmental sensors. Results: We introduce a multi-tier telemedicine system and describe how we optimized our prototype WBAN implementation for computer-assisted physical rehabilitation applications and ambulatory monitoring. The system performs real-time analysis of sensors' data, provides guidance and feedback to the user, and can generate warnings based on the user's state, level of activity, and environmental conditions. In addition, all recorded information can be transferred to medical servers via the Internet and seamlessly integrated into the user's electronic medical record and research databases. Conclusion: WBANs promise inexpensive, unobtrusive, and unsupervised ambulatory monitoring during normal daily activities for prolonged periods of time. To make this technology ubiquitous and affordable, a number of challenging issues should be resolved, such as system design, configuration and customization, seamless integration, standardization, further utilization of common off-the-shelf components, security and privacy, and social issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Taub, E., Uswatte, G., & Pidikiti, R. D. (1999) · PubMed · Cited by 1,168
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
CodeBlue: An Ad Hoc Sensor Network Infrastructure for Emergency Medical Care
Malan, D. J., Fulford-Jones, T. R. F., Welsh, M., & Moulton, S. (2004) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 798
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Self-citationEnhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 614
Activity and location recognition using wearable sensors
Lee, S.-W., & Mase, K. (2002) · IEEE Pervasive Computing · doi:10.1109/mprv.2002.1037719 · Cited by 525
Multi-sensor Activity Context Detection for Wearable Computing
Kern, N., Schiele, B., & Schmidt, A. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39863-9_17 · Cited by 313
Aminian, K., Robert, P., Buchser, E. E., Rutschmann, B., Hayoz, D., & Depairon, M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513304 · Cited by 308
Martin, T., Jovanov, E., & Raskovic, D. (2002) · Digest of Papers. Fourth International Symposium on Wearable Computers · doi:10.1109/iswc.2000.888463 · Cited by 234
Self-citationA Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
Healthwear: medical technology becomes wearable
Pentland, A. (2004) · Computer · doi:10.1109/mc.2004.1297238 · Cited by 192
A 300-μm W 1.9-ghz cmos oscillator utilizing micromachined resonators
Otis, B. P., & Rabaey, J. M. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.813219 · Cited by 179
Shoe-integrated sensor system for wireless gait analysis and real-time feedback
Morris, S. J., & Paradiso, J. A. (2002) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1053379 · Cited by 177
Steele, B. G., Belza, B., Cain, K., Warms, C., Coppersmith, J., & Howard, J. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.10.0045 · Cited by 176
Unsupervised, dynamic identification of physiological and activity context in wearable computing
Krause, A., Siewiorek, D. P., Smailagic, A., & Farringdon, J. (2004) · Seventh IEEE International Symposium on Wearable Computers, 2003. Proceedings. · doi:10.1109/iswc.2003.1241398 · Cited by 153
Medical Monitoring Applications for Wearable Computing
Raskovic, D. (2004) · The Computer Journal · doi:10.1093/comjnl/47.4.495 · Cited by 143
Wearable sensors and telerehabilitation
Winters, J. M., Wang, Y., & Winters, J. M. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213627 · Cited by 130
Wireless personal area networks in telemedical environment
Jovanov, E., Price, J., Raskovic, D., Kavi, K., Martin, T., & Adhami, R. (2002) · Proceedings 2000 IEEE EMBS International Conference on Information Technology Applications in Biomedicine. ITAB-ITIS 2000. Joint Meeting Third IEEE EMBS International Conference on Information Technology Applications in Biomedicine (ITAB'00). Third Works · doi:10.1109/itab.2000.892342 · Cited by 82
Self-citationAdaptive neural network clustering of Web users
Rangarajan, S., Phoha, V. V., Balagani, K. S., Šelmić, R. R., & Iyengar, S. S. (2004) · Computer · doi:10.1109/mc.2004.1297299 · Cited by 70
A Wireless ECG Smart Sensor for Broad Application in Life Threatening Event Detection
Welch, J., Guilak, F., & Baker, S. D. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403967 · Cited by 45
Total energy expenditure estimated using a foot-contact pedometer.
Tharion, W. J., Yokota, M., Buller, M. J., DeLany, J. P., & Hoyt, R. W. (2004) · PubMed · Cited by 29
An implementation of hierarchical signal processing on wireless sensor in TinyOS environment
Otto, C., Gober, J. P., McMurtrey, R. W., Milenković, A., & Jovanov, E. (2005) · ACM Southeast Regional Conference (ACMSE) · doi:10.1145/1167253.1167266 · Cited by 20
Self-citationA BiCMOS Wireless Stimulator Chip for Micromachined Stimulating Microprobes
Ghovanloo, M., & Najafi, K. (2002) · Cited by 16
Winters, J. M., Wang, Y., & Winters, J. M. W. (2003) · Cited by 15
Cited by
A survey on wireless body area networks
Latré, B., Braem, B., Moerman, I., Blondia, C., & Demeester, P. (2011) · Wireless Networks · doi:10.1007/s11276-010-0252-4 · Cited by 1,099
Wireless sensor networks: a survey on recent developments and potential synergies
Rawat, P., Singh, K. D., Chaouchi, H., & Bonnin, J. M. (2014) · The Journal of Supercomputing · doi:10.1007/s11227-013-1021-9 · Cited by 1,054
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Self-citationA Comprehensive Survey of Wireless Body Area Networks: On PHY, MAC, and Network Layers Solutions
Ullah, S., Higgins, H., Braem, B., Latre, B., Blondia, C., Moerman, I., Saleem, S., Rahman, Z., & Kwak, K. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9571-3 · Cited by 811
Chen, C., Jafari, R., & Kehtarnavaz, N. (2015) · 2015 IEEE International Conference on Image Processing (ICIP) · doi:10.1109/icip.2015.7350781 · Cited by 765
Metadata
- Authors
- Jovanov, E., Milenkovic, A., Otto, C., & de Groen, P. C.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2005-03-01
- Volume
- 2
- Issue
- 1
- Pages
- 6-6
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2166618391
- Cited by
- 1,013
- References
- 24
- FWCI
- 31.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.