Shoe-integrated sensor system for wireless gait analysis and real-time feedback

Morris, S.J., Paradiso, J.A. · 2002 · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology

Abstract

We are developing a sensor system for use in clinical gait analysis. This research involves the development of an on-shoe device that can be used for continuous and real-time monitoring of gait. This paper presents the design of an instrumented insole and a removable instrumented shoe attachment. Transmission of the data is in real-time and wireless, providing information about the three-dimensional motion, position, and pressure distribution of the foot. Using pattern recognition and numerical analysis of the calibrated sensor outputs, algorithms will be developed to analyze the data in real-time. Results will be validated by comparison to results from a commercial optical gait analysis system at the Massachusetts General Hospital (MGH) Biomoti on Lab.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2002.1053379

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 5

  1. 10.1109/7333.928571 · DOI · Paper page
  2. 10.1016/0021-9290(94)00074-E · DOI · Paper page
  3. 10.1147/sj.393.0511 · DOI
  4. 10.1109/10.58601 · doi:10.1109/10.58601
  5. 10.1016/S0268-0033(01)00035-3 · DOI · Paper page

Cited by

See all 177

Metadata

Authors
Morris, S. J., & Paradiso, J. A.
Venue
Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology
Publisher
IEEE
Published
2002
Pages
2468-2469 vol.3
OpenAlex
W2162525356
Cited by
177
References
0
FWCI
6.72
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shoe-integrated sensor system for wireless gait analysis and real-time feedback. https://app.cochat.ai/papers/10.1109/iembs.2002.1053379
The paper
Morris, S. J., & Paradiso, J. A. (2002). Shoe-integrated sensor system for wireless gait analysis and real-time feedback. Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2002.1053379

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.