Accelerometer-based wireless body area network to estimate intensity of therapy in post-acute rehabilitation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: It has been suggested that there is a dose-response relationship between the amount of therapy and functional recovery in post-acute rehabilitation care. To this day, only the total time of therapy has been investigated as a potential determinant of this dose-response relationship because of methodological and measurement challenges. The primary objective of this study was to compare time and motion measures during real life physical therapy with estimates of active time (i.e. the time during which a patient is active physically) obtained with a wireless body area network (WBAN) of 3D accelerometer modules positioned at the hip, wrist and ankle. The secondary objective was to assess the differences in estimates of active time when using a single accelerometer module positioned at the hip. Methods: Five patients (77.4 ± 5.2 y) with 4 different admission diagnoses (stroke, lower limb fracture, amputation and immobilization syndrome) were recruited in a post-acute rehabilitation center and observed during their physical therapy sessions throughout their stay. Active time was recorded by a trained observer using a continuous time and motion analysis program running on a Tablet-PC. Two WBAN configurations were used: 1) three accelerometer modules located at the hip, wrist and ankle (M3) and 2) one accelerometer located at the hip (M1). Acceleration signals from the WBANs were synchronized with the observations. Estimates of active time were computed based on the temporal density of the acceleration signals. Results: A total of 62 physical therapy sessions were observed. Strong associations were found between WBANs estimates of active time and time and motion measures of active time. For the combined sessions, the intraclass correlation coefficient (ICC) was 0.93 (P ≤ 0.001) for M3 and 0.79 (P ≤ 0.001) for M1. The mean percentage of differences between observation measures and estimates from the WBAN of active time was -8.7% ± 2.0% using data from M3 and -16.4% ± 10.4% using data from M1. Conclusion: WBANs estimates of active time compare favorably with results from observation-based time and motion measures. While the investigation on the association between active time and outcomes of rehabilitation needs to be studied in a larger scale study, the use of an accelerometer-based WBAN to measure active time is a promising approach that offers a better overall precision than methods relying on work sampling. Depending on the accuracy needed, the use of a single accelerometer module positioned on the hip may still be an interesting alternative to using multiple modules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Effects of Augmented Exercise Therapy Time After Stroke: A Meta-Analysis
Kwakkel, G., van Peppen, R., Wagenaar, R. C., Wood Dauphinee, S., Richards, C., Ashburn, A., Miller, K., Lincoln, N., Partridge, C., Wellwood, I., et al. (2004) · Stroke · doi:10.1161/01.str.0000143153.76460.7d · Cited by 1,081
Bernhardt (2004) · doi:10.1161/01.str.0000120727.40792.40 · Cited by 593
Impact of intensity of practice after stroke: Issues for consideration
Kwakkel, G. (2006) · Disability and Rehabilitation · doi:10.1080/09638280500534861 · Cited by 417
Horn, S. D., DeJong, G., Smout, R. J., Gassaway, J., James, R., & Conroy, B. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.09.016 · Cited by 293
Cited by
Application of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
Wireless sensor networks for rehabilitation applications: Challenges and opportunities
Hadjidj, A., Souil, M., Bouabdallah, A., Challal, Y., & Owen, H. (2013) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2012.10.002 · Cited by 163
Marcroft, C., Khan, A., Embleton, N. D., Trenell, M., & Plötz, T. (2015) · Frontiers in Neurology · doi:10.3389/fneur.2014.00284 · Cited by 146
Peiris, C. L., Taylor, N. F., & Shields, N. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.03.004 · Cited by 55
Metadata
- Authors
- Choquette, S., Hamel, M., & Boissy, P.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2008-09-02
- Volume
- 5
- Issue
- 1
- Pages
- 20-20
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2072120632
- Cited by
- 43
- References
- 6
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerometer-based wireless body area network to estimate intensity of therapy in post-acute rehabilitation. https://app.cochat.ai/papers/10.1186/1743-0003-5-20
- The paper
- Choquette, S., Hamel, M., & Boissy, P. (2008). Accelerometer-based wireless body area network to estimate intensity of therapy in post-acute rehabilitation. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-5-20
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.