Development of a biomechanical energy harvester
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Biomechanical energy harvesting-generating electricity from people during daily activities-is a promising alternative to batteries for powering increasingly sophisticated portable devices. We recently developed a wearable knee-mounted energy harvesting device that generated electricity during human walking. In this methods-focused paper, we explain the physiological principles that guided our design process and present a detailed description of our device design with an emphasis on new analyses. METHODS: Effectively harvesting energy from walking requires a small lightweight device that efficiently converts intermittent, bi-directional, low speed and high torque mechanical power to electricity, and selectively engages power generation to assist muscles in performing negative mechanical work. To achieve this, our device used a one-way clutch to transmit only knee extension motions, a spur gear transmission to amplify the angular speed, a brushless DC rotary magnetic generator to convert the mechanical power into electrical power, a control system to determine when to open and close the power generation circuit based on measurements of knee angle, and a customized orthopaedic knee brace to distribute the device reaction torque over a large leg surface area. RESULTS: The device selectively engaged power generation towards the end of swing extension, assisting knee flexor muscles by producing substantial flexion torque (6.4 Nm), and efficiently converted the input mechanical power into electricity (54.6%). Consequently, six subjects walking at 1.5 m/s generated 4.8 +/- 0.8 W of electrical power with only a 5.0 +/- 21 W increase in metabolic cost. CONCLUSION: Biomechanical energy harvesting is capable of generating substantial amounts of electrical power from walking with little additional user effort making future versions of this technology particularly promising for charging portable medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876
Evaluation of motions and actuation methods for biomechanical energy harvesting
Niu, P., Chapman, P., Riemer, R., & Zhang, X. (2005) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1355442 · Cited by 117
Cited by
A comprehensive review on vibration energy harvesting: Modelling and realization
Wei, C., & Jing, X. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.073 · Cited by 952
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
Giant magnetoelastic effect in soft systems for bioelectronics
Zhou, Y., Zhao, X., Xu, J., Fang, Y., Chen, G., Song, Y., Li, S., & Chen, J. (2021) · Nature Materials · doi:10.1038/s41563-021-01093-1 · Cited by 459
A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
Humans can continuously optimize energetic cost during walking
Selinger, J. C., O’Connor, S. M., Wong, J. D., & Donelan, J. M. (2015) · Current Biology · doi:10.1016/j.cub.2015.08.016 · Cited by 395
Self-citation
Metadata
- Authors
- Li, Q., Naing, V., & Donelan, J. M.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2009-06-23
- Volume
- 6
- Issue
- 1
- Pages
- 22-22
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2057488373
- Cited by
- 121
- References
- 2
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.