Asynchronous BCI control using high-frequency SSVEP
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Steady-State Visual Evoked Potential (SSVEP) is a visual cortical response evoked by repetitive stimuli with a light source flickering at frequencies above 4 Hz and could be classified into three ranges: low (up to 12 Hz), medium (12-30) and high frequency (> 30 Hz). SSVEP-based Brain-Computer Interfaces (BCI) are principally focused on the low and medium range of frequencies whereas there are only a few projects in the high-frequency range. However, they only evaluate the performance of different methods to extract SSVEP. METHODS: This research proposed a high-frequency SSVEP-based asynchronous BCI in order to control the navigation of a mobile object on the screen through a scenario and to reach its final destination. This could help impaired people to navigate a robotic wheelchair. There were three different scenarios with different difficulty levels (easy, medium and difficult). The signal processing method is based on Fourier transform and three EEG measurement channels. RESULTS: The research obtained accuracies ranging in classification from 65% to 100% with Information Transfer Rate varying from 9.4 to 45 bits/min. CONCLUSIONS: Our proposed method allows all subjects participating in the study to control the mobile object and to reach a final target without prior training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 1×
“The SSVEP can be elicited up to at least 90 Hz [3] and could be classified into three ranges: low (up to 12 Hz), medium (12-30) and high frequency (> 30 Hz) [1].”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066 · cited 2×
“SSVEPs are periodic, with a stationary distinct spectrum showing characteristic SSVEPs peaks, stable over time [2].”
BackgroundFrequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Noninvasive Brain-Actuated Control of a Mobile Robot by Human EEG
del R. Millan, J., Renkens, F., Mourino, J., & Gerstner, W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827086 · Cited by 740 · cited 2×
“A method to control a mobile robot in indoor environments was presented in [18], but the subjects need a few days of training to control the mobile robot.”
MethodA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654 · cited 1×
“An updated and interesting review of SSVEP-based BCI is presented in [14], where frequencies, stimulation devices, colour, bit rate and other details of BCIs are offered.”
BackgroundA practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Control of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589 · cited 2×
“Ongoing EEG classification of SSVEP (no high-frequency) based-BCI is implemented in [6,7] using a refractory time (when no decisions are allowed), in order to control grasping with a robotic arm.”
MethodMultiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541 · cited 1×
“However, the majority of SSVEP-based BCI are principally focused in the low and medium range of frequencies [5-8].”
BackgroundPhotic‐ and Pattern‐induced Seizures: A Review for the Epilepsy Foundation of America Working Group
Fisher, R. S., Harding, G., Erba, G., Barkley, G. L., & Wilkins, A. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.31405.x · Cited by 427 · cited 1×
“Besides, low and medium frequency SSVEP ranges interfere with alpha rhythm, and could cause an epileptic seizure as well [16].”
Background
Cited by
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
A lower limb exoskeleton control system based on steady state visual evoked potentials
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056009 · Cited by 221
Brain-computer interface technologies: from signal to action
Ortiz-Rosario, A., & Adeli, H. (2013) · Reviews in the Neurosciences · doi:10.1515/revneuro-2013-0032 · Cited by 213
Cao, T., Wan, F., Wong, C. M., da Cruz, J. N., & Hu, Y. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-28 · Cited by 188
“A frequently used strategy to reduce fatigue is to adopt some relatively comfortable stimulations, such as high frequency stimulation [14,15], high duty cycle stimulation [16] and amplitude modulated stimulation [17].”
BackgroundTo train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Zerafa, R., Camilleri, T., Falzon, O., & Camilleri, K. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaca6e · Cited by 160
“Fourier-based transform methods such as the discrete Fourier transform (DFT) [12], the fast Fourier transform (FFT) [50] and the wavelet transform (WT) [51] have been used to estimate the power values at the frequencies of interest for SSVEP detection.”
MethodCombination of high-frequency SSVEP-based BCI and computer vision for controlling a robotic arm
Chen, X., Zhao, B., Wang, Y., & Gao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf594 · Cited by 159
Asynchronous gaze-independent event-related potential-based brain–computer interface
Aloise, F., Aricò, P., Schettini, F., Salinari, S., Mattia, D., & Cincotti, F. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.07.006 · Cited by 43
Metadata
- Authors
- Diez, P. F., Mut, V. A., Avila Perona, E. M., & Laciar Leber, E.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2011
- Volume
- 8
- Issue
- 1
- Pages
- 39
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2075039042
- Cited by
- 212
- References
- 20
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.