Handheld computers for data entry: high tech has its problems too
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: The use of handheld computers in medicine has increased in the last decade, they are now used in a variety of clinical settings. There is an underlying assumption that electronic data capture is more accurate that paper-based data methods have been rarely tested. This report documents a study to compare the accuracy of hand held computer data capture versus more traditional paper-based methods. METHODS: Clinical nurses involved in a randomised controlled trial collected patient information on a hand held computer in parallel with a paper-based data form. Both sets of data were entered into an access database and the hand held computer data compared to the paper-based data for discrepancies. RESULTS: Error rates from the handheld computers were 67.5 error per 1000 fields, compared to the accepted error rate of 10 per 10,000 field for paper-based double data entry. Error rates were highest in field containing a default value. CONCLUSION: While popular with staff, unacceptable high error rates occurred with hand held computers. Training and ongoing monitoring are needed if hand held computers are to be used for clinical data collection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The use of mobile phones as a data collection tool: A report from a household survey in South Africa
Tomlinson, M., Solomon, W., Singh, Y., Doherty, T., Chopra, M., Ijumba, P., Tsai, A. C., & Jackson, D. (2009) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-9-51 · Cited by 340
“Prior studies have reported technical problems with data upload and download using PDA-based survey systems [24], as well as difficulties in remote sites with data upload due to electrical interference with telephone lines and switchboard difficulties [1].”
Randomized controlled trials: what are they and who needs them?
Pihlstrom, B. L., Curran, A. E., Voelker, H. T., & Kingman, A. (2012) · Periodontology 2000 · doi:10.1111/j.1600-0757.2011.00439.x · Cited by 42
(2021) · doi:10.2196/31130 · Cited by 16
Metadata
- Authors
- Shelby-James, T. M., Abernethy, A. P., McAlindon, A., & Currow, D. C.
- Venue
- Trials
- Published
- 2007-02-20
- Volume
- 8
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1745-6215 (ISSN-L)
- OpenAlex
- W1946734236
- Cited by
- 40
- References
- 0
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Handheld computers for data entry: high tech has its problems too. https://app.cochat.ai/papers/10.1186/1745-6215-8-5
- The paper
- Shelby-James, T. M., Abernethy, A. P., McAlindon, A., & Currow, D. C. (2007). Handheld computers for data entry: high tech has its problems too. Trials. https://doi.org/10.1186/1745-6215-8-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.