Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 115 of the 115 references it cites were found in a registry or an index.

On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion

Open access
Ortiz-Catalan, Max, Brånemark, Rickard, Håkansson, Bo, Delbeke, Jean · 2012 · BioMedical Engineering OnLine

Abstract

The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface electrodes and their highly environmental dependency. This paper describes several implantable electrodes and discusses them as a solution for the natural control of artificial limbs. In this context "natural" is defined as producing control over limb movement analogous to that of an intact physiological system. This includes coordinated and simultaneous movements of different degrees of freedom. It also implies that the input signals must come from nerves or muscles that were originally meant to produce the intended movement and that feedback is perceived as originating in the missing limb without requiring burdensome levels of concentration. After scrutinizing different electrode designs and their clinical implementation, we concluded that the epimysial and cuff electrodes are currently promising candidates to achieving a long-term stable and natural control of robotic prosthetics, provided that communication from the electrodes to the outside of the body is guaranteed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1475-925x-11-33

Cites

115 of 115 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Implantable electrodes (IEs) for prosthetic control. This classification uses 4 categories taking account of the target and the location within the target: 1) extra-muscular, 2) intra-muscular, 3) extra-neural, 4) intra-neural. The invasiveness is proportional to selectivity and inverse to the simplicity of the implantation. IMES stands for Implantable Myoelectric Sensors.
Figure 1 Implantable electrodes (IEs) for prosthetic control. This classification uses 4 categories taking account of the target and the location within the target: 1) extra-muscular, 2) intra-muscular, 3) extra-neural, 4) intra-neural. The invasiveness is proportional to selectivity and inverse to the simplicity of the implantation. IMES stands for Implantable Myoelectric Sensors.CC BY · PubMed Central
Figure 2 A bipolar epimysial electrode. Illustration of a bipolar epimysial electrode with two PtIr discs mounted and covered by silicon sheets in which round windows allow the exposure of the PtIr.
Figure 2 A bipolar epimysial electrode. Illustration of a bipolar epimysial electrode with two PtIr discs mounted and covered by silicon sheets in which round windows allow the exposure of the PtIr.CC BY · PubMed Central
Figure 3 Intra-muscular electrodes. Illustrations of (a) a coiled wire electrode where the exposed tip is the sensing part, and (b) an implantable myoelectric sensor where the sensing part is the electrode caps.
Figure 3 Intra-muscular electrodes. Illustrations of (a) a coiled wire electrode where the exposed tip is the sensing part, and (b) an implantable myoelectric sensor where the sensing part is the electrode caps.CC BY · PubMed Central
Figure 4 Cuff electrode. Cuff electrode with circumferential (A, B, D and E) and discrete (C) contacts with possible differential configurations in bipolar (1), tripolar (2) [46] and short-circuit tripolar (3) [47]. In the latter configuration, the outer electrode pair is short-circuited in order to yield a screening effect [47].
Figure 4 Cuff electrode. Cuff electrode with circumferential (A, B, D and E) and discrete (C) contacts with possible differential configurations in bipolar (1), tripolar (2) [46] and short-circuit tripolar (3) [47]. In the latter configuration, the outer electrode pair is short-circuited in order to yield a screening effect [47].CC BY · PubMed Central
Figure 5 Spiral cuff electrode. Illustration of a self-sizing spiral cuff electrode with continuous or ring contacts.
Figure 5 Spiral cuff electrode. Illustration of a self-sizing spiral cuff electrode with continuous or ring contacts.CC BY · PubMed Central
Figure 6 Intrafascicular electrodes. Illustrations of (a) a polymer-based intrafascicular electrode (polyLIFE) based in the design from [67] and a multi-contact longitudinal intrafascicular electrode.
Figure 6 Intrafascicular electrodes. Illustrations of (a) a polymer-based intrafascicular electrode (polyLIFE) based in the design from [67] and a multi-contact longitudinal intrafascicular electrode.CC BY · PubMed Central
Figure 7 Micro-electrode array. Illustration of a micro-electrode array where the tip of each needle is the sensing area. Sketch based in [73].
Figure 7 Micro-electrode array. Illustration of a micro-electrode array where the tip of each needle is the sensing area. Sketch based in [73].CC BY · PubMed Central
Figure 8 Sieve electrode. Illustration of a sieve electrode where the sensing area is around the holes, even if 100% of the holes do not have a contact.
Figure 8 Sieve electrode. Illustration of a sieve electrode where the sensing area is around the holes, even if 100% of the holes do not have a contact.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 115 references

Cited by

See all 144

Metadata

Authors
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J.
Affiliations
  • Sahlgrenska University Hospital (SE)
  • Chalmers University of Technology (SE)
  • UCLouvain (BE)
Corresponding author
Ortiz-Catalan, Max
Venue
BioMedical Engineering OnLine
Published
2012
Volume
11
Issue
1
Pages
33
ISSN
1475-925X (ISSN-L)
OpenAlex
W2108693629
Cited by
144
References
115
Citations by year
2026: 1 · 2025: 6 · 2024: 9 · 2023: 12 · 2022: 11 · 2021: 10 · 2020: 8 · 2019: 19 · 2018: 11 · 2017: 18 · 2016: 8 · 2015: 14 · 2014: 13 · 2013: 4
FWCI
1.05
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BioMedical Engineering OnLine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
Funders
  • Waalse Gewest
  • VINNOVA (2010-00482)
  • Chalmers Tekniska Högskola
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
implanted electrodes, robotic prostheses, cuff electrodes, neural interfaces, surface electrodes, pattern recognition, long-term stability, feedback perception
MeSH terms
Animals, Artificial Limbs, Electrodes, Implanted, Humans, Muscles, Nervous System Physiological Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion. https://app.cochat.ai/papers/10.1186/1475-925x-11-33
The paper
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012). On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-11-33

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.