Automated detection of near falls: algorithm development and preliminary results
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Falls are a major source of morbidity and mortality among older adults. Unfortunately, self-report is, to a large degree, the gold-standard method for characterizing and quantifying fall frequency. A number of studies have demonstrated that near falls predict falls and that near falls may occur more frequently than falls. These studies suggest that near falls might be an appropriate fall risk measure. However, to date, such investigations have also relied on self-report. The purpose of the present study was to develop a method for automatic detection of near falls, potentially a sensitive, objectivemarker of fall risk and to demonstrate the ability to detect near falls using this approach. Findings: 15 healthy subjects wore a tri-axial accelerometer on the pelvis as they walked on a treadmill under different conditions. Near falls were induced by placing obstacles on the treadmill and were defined using observational analysis. Acceleration-derived parameters were examined as potential indicators of near falls, alone and in various combinations. 21 near falls were observed and compared to 668 "non-near falls" segments, consisting of normal and abnormal (but not near falls) gait. The best single method was based on the maximum peak-to-peak vertical acceleration derivative, with detection rates better than 85% sensitivity and specificity. Conclusions: These findings suggest that tri-axial accelerometers may be used to successfully distinguish near falls from other gait patterns observed in the gait laboratory and may have the potential for improving the objective evaluation of fall risk, perhaps both in the lab and in at home-settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guideline for the Prevention of Falls in Older Persons
Society, A. G., Society, G., Of, A. A., & On Falls Prevention, O. S. P. (2001) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2001.49115.x · Cited by 2,242
Weiss, A., Herman, T., Plotnik, M., Brozgol, M., Maidan, I., Giladi, N., Gurevich, T., & Hausdorff, J. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.015 · Cited by 207 · cited 1×
“Different techniques have been developed to automatically identify falls and related measures with varying degrees of success using sensors embedded in the home environment or body-fixed sensors [7-9].”
BackgroundSelf-citationA pilot study of long-term monitoring of human movements in the home using accelerometry
Mathie, M. J., Coster, A. C. F., Lovell, N. H., Celler, B. G., Lord, S. R., & Tiedemann, A. (2004) · Journal of Telemedicine and Telecare · doi:10.1258/135763304323070788 · Cited by 153
Cited by
Weiss, A., Brozgol, M., Dorfman, M., Herman, T., Shema, S., Giladi, N., & Hausdorff, J. M. (2013) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968313491004 · Cited by 304
Self-citationSensors-Based Wearable Systems for Monitoring of Human Movement and Falls
Shany, T., Redmond, S. J., Narayanan, M. R., & Lovell, N. H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2146246 · Cited by 285
Automatic Fall Monitoring: A Review
Pannurat, N., Thiemjarus, S., & Nantajeewarawat, E. (2014) · Sensors · doi:10.3390/s140712900 · Cited by 237
“(2010) [91] 1 1 F2, F5, F10, F16, F44, F45, F46 TB, RB Sen = 85.”
BackgroundMethodInfluentialSemi-supervised near-miss fall detection for ironworkers with a wearable inertial measurement unit
Yang, K., Ahn, C. R., Vuran, M. C., & Aria, S. S. (2016) · Automation in Construction · doi:10.1016/j.autcon.2016.04.007 · Cited by 202
“[41] investigated subjects walking on treadmills to detect near-falls in normal activities.”
BackgroundMethodInfluentialAziz, O., Musngi, M., Park, E. J., Mori, G., & Robinovitch, S. N. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1504-y · Cited by 202
Metadata
- Authors
- Weiss, A., Shimkin, I., Giladi, N., & Hausdorff, J. M.
- Venue
- BMC Research Notes
- Published
- 2010-03-05
- Volume
- 3
- Issue
- 1
- Pages
- 62-62
- ISSN
- 1756-0500 (ISSN-L)
- OpenAlex
- W2095976411
- Cited by
- 72
- References
- 3
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.