CoChat

Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes

Open access
Sales, Marcelo M, Campbell, Carmen Sílvia G, Morais, Pâmella K, Ernesto, Carlos, Soares-Caldeira, Lúcio F, Russo, Paulo, Motta, Daisy F, Moreira, Sérgio R, Nakamura, Fábio Y, Simões, Herbert G · 2011 · Diabetology & Metabolic Syndrome
Cited by 110

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: While several studies have identified the anaerobic threshold (AT) through the responses of blood lactate, ventilation and blood glucose others have suggested the response of the heart rate variability (HRV) as a method to identify the AT in young healthy individuals. However, the validity of HRV in estimating the lactate threshold (LT) and ventilatory threshold (VT) for individuals with type 2 diabetes (T2D) has not been investigated yet. Aim: To analyze the possibility of identifying the heart rate variability threshold (HRVT) by considering the responses of parasympathetic indicators during incremental exercise test in type 2 diabetics subjects (T2D) and non diabetics individuals (ND). Methods: Nine T2D (55.6 ± 5.7 years, 83.4 ± 26.6 kg, 30.9 ± 5.2 kg.m 2(-1)) and ten ND (50.8 ± 5.1 years, 76.2 ± 14.3 kg, 26.5 ± 3.8 kg.m 2(-1)) underwent to an incremental exercise test (IT) on a cycle ergometer. Heart rate (HR), rate of perceived exertion (RPE), blood lactate and expired gas concentrations were measured at the end of each stage. HRVT was identified through the responses of root mean square successive difference between adjacent R-R intervals (RMSSD) and standard deviation of instantaneous beat-to-beat R-R interval variability (SD1) by considering the last 60 s of each incremental stage, and were known as HRVT by RMSSD and SD1 (HRVT-RMSSD and HRVT-SD1), respectively. Results: No differences were observed within groups for the exercise intensities corresponding to LT, VT, HRVT-RMSSD and HHVT-SD1. Furthermore, a strong relationship were verified among the studied parameters both for T2D (r = 0.68 to 0.87) and ND (r = 0.91 to 0.98) and the Bland & Altman technique confirmed the agreement among them. Conclusion: The HRVT identification by the proposed autonomic indicators (SD1 and RMSSD) were demonstrated to be valid to estimate the LT and VT for both T2D and ND.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1758-5996-3-1

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 110

Metadata

Authors
Sales, M. M., Campbell, C. S. G., Morais, P. K., Ernesto, C., Soares-Caldeira, L. F., Russo, P., Motta, D. F., Moreira, S. R., Nakamura, F. Y., & Simões, H. G.
Venue
Diabetology & Metabolic Syndrome
Published
2011-01-12
Volume
3
Issue
1
Pages
1-1
ISSN
1758-5996 (ISSN-L)
OpenAlex
W2161308334
Cited by
110
References
8
FWCI
13.06
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes. https://app.cochat.ai/papers/10.1186/1758-5996-3-1
The paper
Sales, M. M., Campbell, C. S. G., Morais, P. K., Ernesto, C., Soares-Caldeira, L. F., Russo, P., Motta, D. F., Moreira, S. R., Nakamura, F. Y., & Simões, H. G. (2011). Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes. Diabetology & Metabolic Syndrome. https://doi.org/10.1186/1758-5996-3-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.