The release behavior and kinetic evaluation of tramadol HCl from chemically cross linked Ter polymeric hydrogels
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND AND THE PURPOSE OF THE STUDY: Hydrogels, being stimuli responsive are considered to be effective for targeted and sustained drug delivery. The main purpose for this work was to study the release behavior and kinetic evaluation of Tramadol HCl from chemically cross linked ter polymeric hydrogels. METHODS: Ter-polymers of methacrylate, vinyl acetate and acrylic acid cross linked with ethylene glycol dimethacrylate (EGDMA) were prepared by free radical polymerization. The drug release rates, dynamic swelling behavior and pH sensitivity of hydrogels ranging in composition from 1-10 mol% EGDMA were studied. Tramadol HCl was used as model drug substance. The release behavior was investigated at pH 8 where all formulations exhibited non-Fickian diffusion mechanism. RESULTS AND MAJOR CONCLUSION: Absorbency was found to be more than 99% indicating good drug loading capability of these hydrogels towards the selected drug substance. Formulations designed with increasing amounts of EGDMA had a decreased equilibrium media content as well as media penetrating velocity and thus exhibited a slower drug release rate. Fitting of release data to different kinetic models indicate that the kinetic order shifts from the first to zero order as the concentration of drug was increased in the medium, showing gradual independency of drug release towards its concentration. Formulations with low drug content showed best fitness with Higuchi model whereas those with higher concentration of drug followed Hixson-Crowell model with better correlation values indicating that the drug release from these formulations depends more on change in surface area and diameter of tablets than that on concentration of the drug. Release exponent (n) derived from Korse-Meyer Peppas equation implied that the release of Tramadol HCl from these formulations was generally non-Fickian (n > 0.5 > 1) showing swelling controlled mechanism. The mechanical strength and controlled release capability of the systems indicate that these co-polymeric hydrogels have a great potential to be used as colon drug delivery device through oral administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yee Kuen, C., & Masarudin, M. J. (2022) · Molecules · doi:10.3390/molecules27020473 · Cited by 78
Noureen, S., Noreen, S., Ghumman, S. A., Batool, F., Hameed, H., Hasan, S., Noreen, F., Elsherif, M. A., & Bukhari, S. N. A. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14050916 · Cited by 28
Tulain, U. R., Ahmad, M., & Rashid, A. (2018) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2018.1434668 · Cited by 16
Metadata
- Authors
- Malana, M. A., & Zohra, R.
- Venue
- DARU Journal of Pharmaceutical Sciences
- Published
- 2013-01-18
- Volume
- 21
- Issue
- 1
- Pages
- 10-10
- ISSN
- 1560-8115 (ISSN-L)
- 2008-2231
- OpenAlex
- W2120684240
- Cited by
- 36
- References
- 0
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The release behavior and kinetic evaluation of tramadol HCl from chemically cross linked Ter polymeric hydrogels. https://app.cochat.ai/papers/10.1186/2008-2231-21-10
- The paper
- Malana, M. A., & Zohra, R. (2013). The release behavior and kinetic evaluation of tramadol HCl from chemically cross linked Ter polymeric hydrogels. DARU Journal of Pharmaceutical Sciences. https://doi.org/10.1186/2008-2231-21-10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.