Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

First experience with MR-guided focused ultrasound in the treatment of Parkinson's disease

Open access
Magara, Anouk, Bühler, Robert, Moser, David, Kowalski, Milek, Pourtehrani, Payam, Jeanmonod, Daniel·2014·Journal of Therapeutic Ultrasound

Abstract

BACKGROUND: Radiofrequency (RF) subthalamotomies have been proposed since the 1960s to treat patients suffering from Parkinson's disease (PD). Recently, the magnetic resonance (MR)-guided focused ultrasound technology (MRgFUS) offers the possibility to perform subthalamic thermocoagulations with reduced risks and optimized accuracy. We describe here the initial results of the MRgFUS pallidothalamic tractotomy (PTT), an anatomical and physiological update of the earlier subthalamotomies. METHODS: Thirteen consecutive patients suffering from chronic (mean disease duration 9.7 years) and therapy-resistant PD were treated unilaterally with an MRgFUS PTT. Primary relief assessment indicators were the score reduction of the Unified Parkinson Disease Rating Scale (UPDRS) and the patient estimation of global symptom relief (GSR) taken at 3 months follow-up. Final temperatures at target were between 52°C and 59°C. The MR examinations were performed before the treatment, 2 days and 3 months after it. The accuracy of the targeting was calculated on 2 days post-treatment MR pictures for each PTT lesion. RESULTS: The first four patients received a PTT using the lesional parameters applied for thalamotomies. They experienced clear-cut recurrences at 3 months (mean UPDRS relief 7.6%, mean GSR 22.5%), and their MR showed no sign of thermal lesion in T2-weighted (T2w) images. As a consequence, the treatment protocol was adapted for the following nine patients by applying repetition of the final temperatures 4 to 5 times. That produced thermocoagulations of larger volumes (172 mm(3) against 83 mm(3) for the first four patients), which remained visible at 3 months on T2w images. These nine patients enjoyed a mean UPDRS reduction of 60.9% and a GSR of 56.7%, very close to the results obtained with radiofrequency lesioning. The targeting accuracy for the whole patient group was 0.5, 0.5, and 0.6 mm for the anteroposterior (AP), mediolateral (ML), and dorsoventral (DV) dimensions, respectively. CONCLUSIONS: This study demonstrated the feasibility, safety, and accuracy of the MRgFUS PTT. To obtain similar results as the ones of RF PTT, it was necessary to integrate the fact that white matter, in this case, the pallidothalamic tract, requires repeated thermal exposition to achieve full lesioning and thus full therapeutic effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/2050-5736-2-11

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 263

Metadata

Authors
Magara, A., Bühler, R., Moser, D., Kowalski, M., Pourtehrani, P., & Jeanmonod, D.
Venue
Journal of Therapeutic Ultrasound
Published
2014-05-31
Volume
2
Issue
1
Pages
11-11
ISSN
2050-5736 (ISSN-L)
OpenAlex
W2159144035
Cited by
263
References
17
FWCI
11.25
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: First experience with MR-guided focused ultrasound in the treatment of Parkinson's disease. https://app.cochat.ai/papers/10.1186/2050-5736-2-11
The paper
Magara, A., Bühler, R., Moser, D., Kowalski, M., Pourtehrani, P., & Jeanmonod, D. (2014). First experience with MR-guided focused ultrasound in the treatment of Parkinson's disease. Journal of Therapeutic Ultrasound. https://doi.org/10.1186/2050-5736-2-11

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.