Optimized dose regimen for whole-body FDG-PET imaging
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The European Association of Nuclear Medicine procedure guidelines for whole-body fluorodeoxyglucose positron-emission tomography (FDG-PET) scanning prescribe a dose proportional to the patient's body mass. However, clinical practice shows degraded image quality in obese patients indicating that using an FDG dose proportional to body mass does not overcome size-related degradation of the image quality. The aim of this study was to optimize the administered FDG dose as a function of the patient's body mass or a different patient-dependent parameter, providing whole-body FDG-PET images of a more constant quality. METHODS: Using a linear relation between administered dose and body mass, FDG-PET imaging was performed on two PET/computed tomography scanners (Biograph TruePoint and Biograph mCT, Siemens). Image quality was assessed by the signal-to-noise ratio (SNR) in the liver in 102 patients with a body mass of 46 to 130 kg. Moreover, the best correlating patient-dependent parameter was derived, and an optimized FDG dose regimen was determined. This optimized dose regimen was validated on the Biograph TruePoint system in 42 new patients. Furthermore, this relation was verified by a simulation study, in which patients with different body masses were simulated with cylindrical phantoms. RESULTS: As expected, both PET systems showed a significant decrease in SNR with increasing patient's body mass when using a linear dosage. When image quality was fitted to the patient-dependent parameters, the fit with the patient's body mass had the highest R2. The optimized dose regimen was found to be Anew= c/t × m2, where m is the body mass, t is the acquisition time per bed position and c is a constant (depending on scanner type). Using this relation, SNR no longer varied with the patient's body mass. This quadratic relation between dose and body mass was confirmed by the simulation study. CONCLUSION: A quadratic relation between FDG dose and the patient's body mass is recommended. Both simulations and clinical observations confirm that image quality remains constant across patients when this quadratic dose regimen is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536 · cited 1×
“In addition, reconstructions using a position-dependent point spread function (PSF) have also been introduced [13].”
MethodFocus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335 · cited 1×
“Since the publication of [1], more PET cameras have been equipped with a time of flight (TOF) option [10-12].”
BackgroundVariations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136 · cited 4×
“The statistical analysis was performed using SigmaPlot for Windows, version 10.0 (Systat Software Inc., Chicago, IL, USA).”
BackgroundInfluentialMasuda, Y., Kondo, C., Matsuo, Y., Uetani, M., & Kusakabe, K. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.060590 · Cited by 104
Cited by
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Self-citationQuantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Self-citationTrägårdh, E., Minarik, D., Almquist, H., Bitzén, U., Garpered, S., Hvittfelt, E., Olsson, B., & Oddstig, J. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0535-4 · Cited by 50
te Riet, J., Rijnsdorp, S., Roef, M. J., & Arends, A. J. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0262-y · Cited by 46
“with W weight in kg, which results in a constant SNR for the liver [6].”
BackgroundMethodPatient-specific optimisation of administered activity and acquisition times for 18F-FDG PET imaging
Wickham, F., McMeekin, H., Burniston, M., McCool, D., Pencharz, D., Skillen, A., & Wagner, T. (2017) · EJNMMI Research · doi:10.1186/s13550-016-0250-3 · Cited by 25
“Noise equivalent count rates tend to be lower for heavier patients [3], and it has been demonstrated that even if activity is administered in proportion to the patient’s weight, image quality is lower in heavier patients [4, 5].”
Background
Metadata
- Authors
- de Groot, E. H., Post, N., Boellaard, R., Wagenaar, N. R., Willemsen, A. T., & van Dalen, J. A.
- Venue
- EJNMMI Research
- Published
- 2013
- Volume
- 3
- Issue
- 1
- Pages
- 63
- ISSN
- 2191-219X (ISSN-L)
- OpenAlex
- W2131819962
- Cited by
- 114
- References
- 4
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimized dose regimen for whole-body FDG-PET imaging. https://app.cochat.ai/papers/10.1186/2191-219x-3-63
- The paper
- de Groot, E. H., Post, N., Boellaard, R., Wagenaar, N. R., Willemsen, A. T., & van Dalen, J. A. (2013). Optimized dose regimen for whole-body FDG-PET imaging. EJNMMI Research. https://doi.org/10.1186/2191-219x-3-63
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.