Correction of scan time dependence of standard uptake values in oncological PET
Open accessAbstract
BACKGROUND: Standard uptake values (SUV) as well as tumor-to-blood standard uptake ratios (SUR) measured with [ 18F-]fluorodeoxyglucose (FDG) PET are time dependent. This poses a serious problem for reliable quantification since variability of scan start time relative to the time of injection is a persistent issue in clinical oncological Positron emission tomography (PET). In this work, we present a method for scan time correction of, both, SUR and SUV. METHODS: Assuming irreversible FDG kinetics, SUR is linearly correlated to Km (the metabolic rate of FDG), where the slope only depends on the shape of the arterial input function (AIF) and on scan time. Considering the approximately invariant shape of the AIF, this slope (the 'Patlak time') is an investigation independent function of scan time. This fact can be used to map SUR and SUV values from different investigations to a common time point for quantitative comparison. Additionally, it turns out that modelling the invariant AIF shape by an inverse power law is possible which further simplifies the correction procedure. The procedure was evaluated in 15 fully dynamic investigations of liver metastases from colorectal cancer and 10 dual time point (DTP) measurements. From each dynamic study, three 'static scans' at T=20,35,and 55 min post injection (p.i.) were created, where the last scan defined the reference time point to which the uptake values measured in the other two were corrected. The corrected uptake values were then compared to those actually measured at the reference time. For the DTP studies, the first scan (acquired at (78.1 ± 15.9) min p.i.) served as the reference, and the uptake values from the second scan (acquired (39.2 ± 9.9) min later) were corrected accordingly and compared to the reference. RESULTS: For the dynamic data, the observed difference between uncorrected values and values at reference time was (-52±4.5)% at T=20 min and (-31±3.7)% at T=35 min for SUR and (-30±6.6)% at T=20 min and (-16±4)% at T=35 min for SUV. After correction, the difference was reduced to (-2.9±6.6)% at T=20 min and (-2.7±5)% at T=35 min for SUR and (1.9% ± 6.2)% at T=20 min and (1.7 ± 3.3)% at T=35 min for SUV. For the DTP studies, the observed differences of SUR and SUV between late and early scans were (48 ± 11)% and (24 ± 8.4)%, respectively. After correction, these differences were reduced to (2.6 ± 6.9)% and (-2.4±7.3)%, respectively. CONCLUSION: If FDG kinetics is irreversible in the targeted tissue, correction of SUV and SUR for scan time variability is possible with good accuracy. The correction distinctly improves comparability of lesion uptake values measured at different times post injection.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
SUV of tumor lesions increases steadily over time after [18F]FDG injection.
“The SUV of tumor lesions, therefore, increases steadily over time after [18F]FDG injection [70,71].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [71]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2000) · doi:10.32614/r.manuals · Cited by 355,706 · see citing works
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777 · see citing works
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,565 · see citing works
Patlak, C. S., & Blasberg, R. G. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.87 · Cited by 1,673 · see citing works
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,329 · see citing works
Self-citationSUV: standard uptake or silly useless value?
Keyes, J. W. (1995) · PubMed · Cited by 803 · see citing works
Huang, S. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00155-4 · Cited by 458 · see citing works
The dose uptake ratio as an index of glucose metabolism: useful parameter or oversimplification?
Hamberg, L. M., Hunter, G. J. S., Alpert, N. M., Choi, N. C., Babich, J. W., & Fischman, A. J. (1994) · PubMed · Cited by 395 · see citing works
Sugawara, Y., Zasadny, K. R., Neuhoff, A. W., & Wahl, R. L. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv37521 · Cited by 265 · see citing works
Kim, C. K., Gupta, N. C., Chandramouli, B., & Alavi, A. A. (1994) · PubMed · Cited by 229 · see citing works
Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136 · see citing works
van den Hoff, J., Oehme, L., Schramm, G., Maus, J., Lougovski, A., Petr, J., Beuthien-Baumann, B., & Hofheinz, F. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-77 · Cited by 127 · see citing works
Self-citationBeaulieu, S., Kinahan, P. E., Tseng, J. R., Dunnwald, L. K., Schubert, E. K., Pham, P., Lewellen, B., & Mankoff, D. A. (2003) · PubMed · Cited by 124 · see citing works
Automatic volume delineation in oncological PET
Hofheinz, F., Pötzsch, C., Oehme, L., Beuthien‐Baumann, B., Steinbach, J., Kotzerke, J., & van den Hoff, J. (2011) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0419-11-07 · Cited by 91 · see citing works
Self-citationReference Range for Intrapatient Variability in Blood-Pool and Liver SUV for <sup>18</sup>F-FDG PET
Boktor, R. R., Walker, G., Stacey, R., Gledhill, S., & Pitman, A. G. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.108530 · Cited by 90 · see citing works
Vriens, D., de Geus‐Oei, L., Oyen, W. J. G., & Visser, E. P. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065243 · Cited by 83 · see citing works
Hofheinz, F., Pötzsch, C., Oehme, L., Beuthien‐Baumann, B., Steinbach, J., Kotzerke, J., & van den Hoff, J. (2012) · Nuklearmedizin - NuclearMedicine · Cited by 43 · see citing works
Self-citationOptimizing Imaging Time for Improved Performance in Oncology PET Studies
Thie, J. A. (2002) · Molecular Imaging and Biology · doi:10.1016/s1095-0397(01)00061-9 · Cited by 38 · see citing works
Tahari, A. K., & Wahl, R. L. (2013) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12140 · Cited by 13 · see citing works
Flagged first, then by citations
1 of the 20 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Bütof, R., Hofheinz, F., Zöphel, K., Stadelmann, T., Schmollack, J., Jentsch, C., Löck, S., Kotzerke, J., Baumann, M. A., & van den Hoff, J. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.155309 · Cited by 67 · see citing works
Self-citationKramer, G. M., Frings, V., Hoetjes, N., Hoekstra, O. S., Smit, E. F., de Langen, A. J., & Boellaard, R. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.170225 · Cited by 65 · see citing works
Bailey, D. L., Antoch, G., Bartenstein, P., Barthel, H., Beer, A. J., Bisdas, S., Bluemke, D. A., Boellaard, R., Claussen, C. D., Franzius, C., et al. (2015) · Molecular Imaging and Biology · doi:10.1007/s11307-014-0818-0 · Cited by 64 · see citing works
Hofheinz, F., Bütof, R., Apostolova, I., Zöphel, K., Steffen, I., Amthauer, H., Kotzerke, J., Baumann, M., & van den Hoff, J. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0174-y · Cited by 55 · see citing works
Self-citationInfluences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 50 · see citing works
“The SUV of tumor lesions, therefore, increases steadily over time after [18F]FDG injection [70,71].”
BackgroundSelf-citationPitfalls and Limitations of Radionuclide and Hybrid Imaging in Infection and Inflammation
Glaudemans, A. W. J. M., Israel, O., & Slart, R. H. J. A. (2015) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2015.02.005 · Cited by 48 · see citing works
Hofheinz, F., Li, Y., Steffen, I. G., Lin, Q., Lili, C., Wu, H., van den Hoff, J., & Zschaeck, S. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04307-6 · Cited by 46 · see citing works
Self-citationHofheinz, F., van den Hoff, J., Steffen, I. G., Lougovski, A., Ego, K., Amthauer, H., & Apostolova, I. I. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0208-5 · Cited by 44 · see citing works
Self-citationHofheinz, F., Apostolova, I. I., Oehme, L., Kotzerke, J., & van den Hoff, J. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.190736 · Cited by 36 · see citing works
Self-citationBraune, A., Hofheinz, F., Bluth, T., Kiss, T., Wittenstein, J., Scharffenberg, M., Kotzerke, J., & de Abreu, M. G. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226597 · Cited by 36 · see citing works
Self-citationVerloh, N., Einspieler, I., Utpatel, K., Menhart, K., Brunner, S. M., Hofheinz, F., van den Hoff, J., Wiggermann, P., Evert, M., Stroszczynski, C., et al. (2018) · EJNMMI Research · doi:10.1186/s13550-018-0452-y · Cited by 34 · see citing works
Self-citationSollini, M., Bandera, F., & Kirienko, M. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04531-0 · Cited by 30 · see citing works
Combined brain and spinal FDG PET allows differentiation between ALS and ALS mimics
Weehaeghe, D. V., Devrome, M., Schramm, G., Vocht, J. D., Deckers, W., Baete, K., Damme, P. V., Koole, M. J. B., & Laere, K. V. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04786-y · Cited by 30 · see citing works
Self-citationZschaeck, S., Li, Y., Lin, Q., Beck, M., Amthauer, H., Bauersachs, L., Hajiyianni, M., Rogasch, J., Ehrhardt, V. H., Kalinauskaite, G., et al. (2020) · PLOS ONE · doi:10.1371/journal.pone.0236841 · Cited by 28 · see citing works
Self-citation18F-FDG PET/MRI for therapy response assessment in sarcoma: comparison of PET and MR imaging results
Schuler, M. K., Platzek, I., Beuthien‐Baumann, B., Fenchel, M. C., Ehninger, G., & van den Hoff, J. (2015) · Clinical Imaging · doi:10.1016/j.clinimag.2015.05.014 · Cited by 28 · see citing works
Self-citationBütof, R., Hofheinz, F., Zöphel, K., Schmollack, J., Jentsch, C., Zschaeck, S., Kotzerke, J., van den Hoff, J., & Baumann, M. A. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.207670 · Cited by 26 · see citing works
Self-citationDistribution and kinetics of the Kv1.3-blocking peptide HsTX1[R14A] in experimental rats
Bergmann, R., Kubeil, M., Zarschler, K., Chhabra, S., Tajhya, R. B., Beeton, C., Pennington, M. W., Bachmann, M. P., Norton, R. S., & Stephan, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-03998-x · Cited by 25 · see citing works
Hybrid FDG-PET/MR imaging of chronic osteomyelitis: a prospective case series
Hulsen, D. J. W., Geurts, J. A. P., Arts, J. J. C., Loeffen, D. V., Mitea, C., & Vöö, S. A. (2019) · European Journal of Hybrid Imaging · doi:10.1186/s41824-019-0055-5 · Cited by 25 · see citing works
Kurland, B. F., Muzi, M., Peterson, L. M., Doot, R. K., Wangerin, K. A., Mankoff, D. A., Linden, H. M., & Kinahan, P. E. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.162289 · Cited by 24 · see citing works
Hristova, I., Boellaard, R., Vogel, W. V., Mottaghy, F. M., Marreaud, S. I., Collette, S., Schöffski, P., Sanfilippo, R. G., Dewji, R., van der Graaf, W., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3002-0 · Cited by 23 · see citing works
Wijngaarden, J. E., Huisman, M. C., Jauw, Y. W. S., van Dongen, G. A. M. S., Greuter, H. N. J. M., Schuit, R. C., Cleveland, M., Gootjes, E. C., Vugts, D. J., van Oordt, C. W. M. D. H., et al. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-023-06151-1 · Cited by 17 · see citing works
Einspieler, I., Mergen, V., Wendorff, H., Haller, B., Eiber, M. J., Schwaiger, M., Nekolla, S. G., & Mustafa, M. (2020) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-02011-4 · Cited by 16 · see citing works
Das, S. K., McGurk, R., Miften, M. M., Mutic, S., Bowsher, J. E., Bayouth, J. E., Erdi, Y. E., Mawlawi, O. R., Boellaard, R., Bowen, S. R., et al. (2019) · Medical Physics · doi:10.1002/mp.13676 · Cited by 15 · see citing works
Zschaeck, S., Hofheinz, F., Zöphel, K., Bütof, R., Jentsch, C., Schmollack, J., Löck, S., Kotzerke, J., Baretton, G. B., Weitz, J., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3742-0 · Cited by 12 · see citing works
Self-citationVrist, M. H., Bech, J. N., Lauridsen, T. G., Fynbo, C. A., & Theil, J. (2021) · EJNMMI Research · doi:10.1186/s13550-021-00859-7 · Cited by 9 · see citing works
Li, Y., Hofheinz, F., Furth, C., Lili, C., Wu, H., Ghadjar, P., & Zschaeck, S. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3996-1 · Cited by 8 · see citing works
Self-citationWilliams, J. M., Rani, S. D., Li, X., Arlinghaus, L. R., Lee, T., MacDonald, L. R., Partridge, S. C., Kang, H., Whisenant, J. G., Abramson, R. G., et al. (2015) · Medical Physics · doi:10.1118/1.4921363 · Cited by 8 · see citing works
Nikulin, P., Hofheinz, F., Maus, J., Li, Y., Bütof, R., Lange, C., Furth, C., Zschaeck, S., Kreissl, M. C., Kotzerke, J., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04991-9 · Cited by 7 · see citing works
Self-citationZschaeck, S., Li, Y., Bütof, R., Lili, C., Wu, H., Troost, E. G. C., Beck, M., Amthauer, H., Kaul, D., Kotzerke, J., et al. (2020) · International Journal of Cancer · doi:10.1002/ijc.32897 · Cited by 6 · see citing works
Self-citationAsphericity derived from [18F]FDG PET as a new prognostic parameter in cervical cancer patients
Cegła, P., Hofheinz, F., Burchardt, E., Czepczyński, R., Kubiak, A., van den Hoff, J., Nikulin, P., Boś, A., Roszak, A., & Cholewiński, W. (2023) · Scientific Reports · doi:10.1038/s41598-023-35191-8 · Cited by 6 · see citing works
Self-citationPopovic, M. M., Talarico, O. S., van den Hoff, J., Kunin, H. S., Zhang, Z., Lafontaine, D., Doğan, S., Leung, J., Kaye, E., Czmielewski, C., et al. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00707-0 · Cited by 6 · see citing works
Hu, B., Jin, H., Li, X., Wu, X., Xu, J., & Gao, Y. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.943933 · Cited by 4 · see citing works
Interobserver variability of image-derived arterial blood SUV in whole-body FDG PET
Hofheinz, F., Maus, J., Zschaeck, S., Rogasch, J. M. M., Schramm, G., Oehme, L., Apostolova, I. I., Kotzerke, J., & van den Hoff, J. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0486-9 · Cited by 4 · see citing works
Self-citationDurand, E., & Besson, F. L. (2015) · Médecine Nucléaire · doi:10.1016/j.mednuc.2015.01.002 · Cited by 4 · see citing works
Quantification: there is more to worry about than good scanner hardware and reliable calibration
Kotzerke, J., & van den Hoff, J. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3808-z · Cited by 4 · see citing works
Self-citationRepeatability of Tumor SUV Quantification: The Role of Variable Blood SUV
van den Hoff, J., & Hofheinz, F. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.161570 · Cited by 4 · see citing works
Self-citationBeuthien‐Baumann, B. (2018) · Der Radiologe · doi:10.1007/s00117-018-0380-x · Cited by 3 · see citing works
Self-citationİnce, S., Laforest, R. A., Itani, M., Prasad, V., Derenoncourt, P.-R., Crandall, J. P., Ashrafinia, S., Smith, A. M., Wahl, R. L., & Fraum, T. J. (2024) · Journal of Nuclear Medicine · doi:10.2967/jnumed.123.266469 · Cited by 3 · see citing works
An improved Patlak-based Ki parametric imaging approach for clinical 18F-FDG total-body PET
Gu, W., Zhu, Z., Liu, Z., Wang, Y., Li, Y., Xu, T., Liu, W., Wang, K., Luo, G., & Zhou, Y. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad9ce4 · Cited by 3 · see citing works
He, M., Baker, S. L., Shah, V. D., Lockhart, S. N., & Jagust, W. J. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2870441 · Cited by 3 · see citing works
Braun, T., Manava, P., Ludwigs, S., Lell, M., & Schoen, M. (2018) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0919-17-08 · Cited by 3 · see citing works
How to obtain the image-derived blood concentration from 89Zr-immuno-PET scans
Wijngaarden, J. E., Ahbari, A., Pouw, J. E. E., Greuter, H. N. J. M., Bahce, I., Zwezerijnen, G. J. C., Vugts, D. J., van Dongen, G. A. M. S., Boellaard, R., van Oordt, C. W. M. D. H., et al. (2024) · EJNMMI Physics · doi:10.1186/s40658-024-00621-7 · Cited by 2 · see citing works
Is There a Relevant Imaging Time for Optimal Quantitative 89Zr-DFO-Daratumumab PET Imaging?
Laffon, É., & Marthan, R. (2021) · Radiology · doi:10.1148/radiol.2021204454 · Cited by 2 · see citing works
Jin, H., Hu, B., Zhang, J., Long, Y. H., Xuan, A., Wu, X., Xu, J., & Gao, Y. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1578419 · Cited by 1 · see citing works
Sag, S. J. M., Menhart, K., Hitzenbichler, F., Schmid, Ç., Hofheinz, F., van den Hoff, J., Maier, L. S., Hellwig, D., Grosse, J., & Sag, C. M. (2023) · Journal of Nuclear Cardiology · doi:10.1007/s12350-023-03285-5 · Cited by 1 · see citing works
Self-citationLaffon, É., & Marthan, R. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186676 · Cited by 1 · see citing works
Monitoring scanner calibration using the image-derived arterial blood SUV in whole-body FDG-PET
Maus, J., Hofheinz, F., Apostolova, I. I., Kreissl, M. C., Kotzerke, J., & van den Hoff, J. (2018) · EJNMMI Research · doi:10.1186/s13550-018-0391-7
Self-citationNguyen, T., Baun, C., & Høilund‐Carlsen, P. F. (2018) · Medicine · doi:10.1097/md.0000000000012312
SUR for mediastinal metastatic lymph node status in non-small-cell lung cancer patients
Laffon, É., & Marthan, R. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04876-x
van den Hoff, J. (2017) · Springer eBooks · doi:10.1007/978-3-319-42202-2_21
Bildgebung, Kinetik, Quantifizierung
Braune, A., & Großer, O. S. (2023) · Angewandte Nuklearmedizin · doi:10.1055/a-1802-8602
Yamashita, Y., HIRAKAWA, K., Yoshidome, S., Awamoto, S., Kitamura, Y., Isoda, T., Baba, S., Kobayashi, K., Kato, T., & Ishigami, K. (2025) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.125.270450
Additional file 1 of How to obtain the image-derived blood concentration from 89Zr-immuno-PET scans
Wijngaarden, J. E., Ahbari, A., Pouw, J. E. E., Greuter, H. N. J. M., Bahce, I., Zwezerijnen, G. J. C., Vugts, D. J., van Dongen, G. A. M. S., Boellaard, R., van Oordt, C. W. M. D. H., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26677934
Popovic, M., Talarico, O. S., van den Hoff, J., Kunin, H. S., Zhang, Z., Lafontaine, D., Dogan, S., Leung, J., Kaye, E., Czmielewski, C., et al. (2020) · Figshare · doi:10.6084/m9.figshare.13279805
Self-citationNamías, M., Pedro, A. P. S., Pelegrina, L. T., Brenner, L. C., Agüero, R., Campisi, R., & Geronazzo, R. J. (2026) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2026.103001
- Authors
- van den Hoff, J., Lougovski, A., Schramm, G., Maus, J., Oehme, L., Petr, J., Beuthien-Baumann, B., Kotzerke, J., & Hofheinz, F.
- Affiliations
- Helmholtz-Zentrum Dresden-Rossendorf (DE)
- University Hospital Carl Gustav Carus (DE)
- Venue
- EJNMMI Research
- Published
- 2014
- Volume
- 4
- Issue
- 1
- Pages
- 18
- ISSN
- 2191-219X (ISSN-L)
- PMC
- PMC3992152
- OpenAlex
- W2113612612
- Cited by
- 55
- References
- 20
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 8 · 2019: 6 · 2018: 8 · 2017: 5 · 2016: 4 · 2015: 9
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- EJNMMI Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Bundesministerium für Bildung und Forschung
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Keywords
- standardized uptake value, FDG-PET, arterial input function, inverse power law, liver metastasis, colorectal cancer, dual-time-point imaging, dynamic PET, PET quantification, tumor glucose metabolism
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review