Cited by 55Medical Imaging Techniques and ApplicationsRadiopharmaceutical Chemistry and ApplicationsLung Cancer Diagnosis and Treatment

Correction of scan time dependence of standard uptake values in oncological PET

Open access
van den Hoff, Jörg, Lougovski, Alexandr, Schramm, Georg, Maus, Jens, Oehme, Liane, Petr, Jan, Beuthien-Baumann, Bettina, Kotzerke, Jörg +1 more·2014·EJNMMI Research

Abstract

BACKGROUND: Standard uptake values (SUV) as well as tumor-to-blood standard uptake ratios (SUR) measured with [ 18F-]fluorodeoxyglucose (FDG) PET are time dependent. This poses a serious problem for reliable quantification since variability of scan start time relative to the time of injection is a persistent issue in clinical oncological Positron emission tomography (PET). In this work, we present a method for scan time correction of, both, SUR and SUV. METHODS: Assuming irreversible FDG kinetics, SUR is linearly correlated to Km (the metabolic rate of FDG), where the slope only depends on the shape of the arterial input function (AIF) and on scan time. Considering the approximately invariant shape of the AIF, this slope (the 'Patlak time') is an investigation independent function of scan time. This fact can be used to map SUR and SUV values from different investigations to a common time point for quantitative comparison. Additionally, it turns out that modelling the invariant AIF shape by an inverse power law is possible which further simplifies the correction procedure. The procedure was evaluated in 15 fully dynamic investigations of liver metastases from colorectal cancer and 10 dual time point (DTP) measurements. From each dynamic study, three 'static scans' at T=20,35,and 55 min post injection (p.i.) were created, where the last scan defined the reference time point to which the uptake values measured in the other two were corrected. The corrected uptake values were then compared to those actually measured at the reference time. For the DTP studies, the first scan (acquired at (78.1 ± 15.9) min p.i.) served as the reference, and the uptake values from the second scan (acquired (39.2 ± 9.9) min later) were corrected accordingly and compared to the reference. RESULTS: For the dynamic data, the observed difference between uncorrected values and values at reference time was (-52±4.5)% at T=20 min and (-31±3.7)% at T=35 min for SUR and (-30±6.6)% at T=20 min and (-16±4)% at T=35 min for SUV. After correction, the difference was reduced to (-2.9±6.6)% at T=20 min and (-2.7±5)% at T=35 min for SUR and (1.9% ± 6.2)% at T=20 min and (1.7 ± 3.3)% at T=35 min for SUV. For the DTP studies, the observed differences of SUR and SUV between late and early scans were (48 ± 11)% and (24 ± 8.4)%, respectively. After correction, these differences were reduced to (2.6 ± 6.9)% and (-2.4±7.3)%, respectively. CONCLUSION: If FDG kinetics is irreversible in the targeted tissue, correction of SUV and SUR for scan time variability is possible with good accuracy. The correction distinctly improves comparability of lesion uptake values measured at different times post injection.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/2191-219x-4-18

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • SUV of tumor lesions increases steadily over time after [18F]FDG injection.

    “The SUV of tumor lesions, therefore, increases steadily over time after [18F]FDG injection [70,71].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [71]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 20 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
van den Hoff, J., Lougovski, A., Schramm, G., Maus, J., Oehme, L., Petr, J., Beuthien-Baumann, B., Kotzerke, J., & Hofheinz, F.
Affiliations
  • Helmholtz-Zentrum Dresden-Rossendorf (DE)
  • University Hospital Carl Gustav Carus (DE)
Venue
EJNMMI Research
Published
2014
Volume
4
Issue
1
Pages
18
ISSN
2191-219X (ISSN-L)
OpenAlex
W2113612612
Cited by
55
References
20
Citations by year
2026: 1 · 2025: 2 · 2024: 4 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 8 · 2019: 6 · 2018: 8 · 2017: 5 · 2016: 4 · 2015: 9
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • EJNMMI Research (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Bundesministerium für Bildung und Forschung
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
Keywords
standardized uptake value, FDG-PET, arterial input function, inverse power law, liver metastasis, colorectal cancer, dual-time-point imaging, dynamic PET, PET quantification, tumor glucose metabolism

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review