Novel red fluorophores with superior performance in STED microscopy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In optical microscopy, most red-emitting dyes provide only moderate performance due to unspecific binding, poor labeling efficiency, and insufficient brightness. Here we report on four novel red fluororescent dyes, including the first phosphorylated dye, created by combining a rigidized rhodamine backbone with various polar groups. They exhibit large fluorescence quantum yields and improved NHS ester stability. While these fluorophores are highly suitable for fluorescence microscopy in general, they excel in stimulated emission depletion (STED) microscopy, providing < 25 nm spatial resolution in raw images of cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Self-citationWurm, C. A., Neumann, D., Lauterbach, M. A., Harke, B., Egner, A., Hell, S. W., & Jakobs, S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1107553108 · Cited by 173 · cited 2×
“While KK114 was successfully applied in confocal and STED microscopy (Bückers et al. 2011; Hua et al. 2011; Wurm et al. 2011), the disadvantage of this compound is the negative net charge of the dye residue (making dye conjugates tentatively not cell-permeable), and the moderate hydrolytic…”
MethodSelf-citation
Cited by
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Universal quenching of common fluorescent probes by water and alcohols
Maillard, J., Klehs, K., Rumble, C., Vauthey, E., Heilemann, M., & Fürstenberg, A. (2021) · Chemical Science · doi:10.1039/d0sc05431c · Cited by 306
Coaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution
Göttfert, F., Wurm, C. A., Mueller, V., Berning, S., Cordes, V. C., Honigmann, A., & Hell, S. W. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.029 · Cited by 298
Self-citationChoose Your Label Wisely: Water-Soluble Fluorophores Often Interact with Lipid Bilayers
Hughes, L. D., Rawle, R. J., & Boxer, S. G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087649 · Cited by 290
Seeing beyond the limit: A guide to choosing the right super-resolution microscopy technique
Valli, J., Garcia-Burgos, A., Rooney, L. M., Vale de Melo e Oliveira, B., Duncan, R. R., & Rickman, C. (2021) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2021.100791 · Cited by 159
“However, this is dependent on the STED lasers present on the system, and the availability of efficiently depleted fluorophores can become limited as the number of desired colors increases (46).”
Background
Metadata
- Authors
- Wurm, C. A., Kolmakov, K., Göttfert, F., Ta, H., Bossi, M., Schill, H., Berning, S., Jakobs, S., Donnert, G., Belov, V. N., & Hell, S. W.
- Venue
- Optical Nanoscopy
- Published
- 2012
- Volume
- 1
- Issue
- 1
- Pages
- 7
- ISSN
- 2192-2853 (ISSN-L)
- OpenAlex
- W2130097076
- Cited by
- 120
- References
- 2
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel red fluorophores with superior performance in STED microscopy. https://app.cochat.ai/papers/10.1186/2192-2853-1-7
- The paper
- Wurm, C. A., Kolmakov, K., Göttfert, F., Ta, H., Bossi, M., Schill, H., Berning, S., Jakobs, S., Donnert, G., Belov, V. N., & Hell, S. W. (2012). Novel red fluorophores with superior performance in STED microscopy. Optical Nanoscopy. https://doi.org/10.1186/2192-2853-1-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.