CoChat

Mortality prediction using SAPS II: an update for French intensive care units

Open access
Le Gall, Jean Roger, Neumann, Anke, Hemery, François, Bleriot, Jean Pierre, Fulgencio, Jean Pierre, Garrigues, Bernard, Gouzes, Christian, Lepage, Eric, Moine, Pierre, Villers, Daniel · 2005 · Critical Care
Cited by 174

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Introduction: The standardized mortality ratio (SMR) is commonly used for benchmarking intensive care units (ICUs). Available mortality prediction models are outdated and must be adapted to current populations of interest. The objective of this study was to improve the Simplified Acute Physiology Score (SAPS) II for mortality prediction in ICUs, thereby improving SMR estimates. Method: A retrospective data base study was conducted in patients hospitalized in 106 French ICUs between 1 January 1998 and 31 December 1999. A total of 77,490 evaluable admissions were split into a training set and a validation set. Calibration and discrimination were determined for the original SAPS II, a customized SAPS II and an expanded SAPS II developed in the training set by adding six admission variables: age, sex, length of pre-ICU hospital stay, patient location before ICU, clinical category and whether drug overdose was present. The training set was used for internal validation and the validation set for external validation. Results: With the original SAPS II calibration was poor, with marked underestimation of observed mortality, whereas discrimination was good (area under the receiver operating characteristic curve 0.858). Customization improved calibration but had poor uniformity of fit; discrimination was unchanged. The expanded SAPS II exhibited good calibration, good uniformity of fit and better discrimination (area under the receiver operating characteristic curve 0.879). The SMR in the validation set was 1.007 (confidence interval 0.985–1.028). Some ICUs had better and others worse performance with the expanded SAPS II than with the customized SAPS II. Conclusion: The original SAPS II model did not perform sufficiently well to be useful for benchmarking in France. Customization improved the statistical qualities of the model but gave poor uniformity of fit. Adding simple variables to create an expanded SAPS II model led to better calibration, discrimination and uniformity of fit, producing a tool suitable for benchmarking.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc3821

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 174

Metadata

Authors
Le Gall, J. R., Neumann, A., Hemery, F., Bleriot, J. P., Fulgencio, J. P., Garrigues, B., Gouzes, C., Lepage, E., Moine, P., & Villers, D.
Venue
Critical Care
Published
2005-10-06
Volume
9
Issue
6
Pages
R645-52
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2119254210
Cited by
174
References
1
FWCI
4.58
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.