Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Impact of computerized physician order entry on medication prescription errors in the intensive care unit: a controlled cross-sectional trial

Open access
Colpaert, Kirsten, Claus, Barbara, Somers, Annemie, Vandewoude, Koenraad, Robays, Hugo, Decruyenaere, Johan·2006·Critical Care

Abstract

Introduction: Medication errors in the intensive care unit (ICU) are frequent and lead to attributable patient morbidity and mortality, increased length of ICU stay and substantial extra costs. We investigated if the introduction of a computerized ICU system (Centricity Critical Care Clinisoft, GE Healthcare) reduced the incidence and severity of medication prescription errors (MPEs). Methods: A prospective trial was conducted in a paper-based unit (PB-U) versus a computerized unit (C-U) in a 22-bed ICU of a tertiary university hospital. Every medication order and medication prescription error was validated by a clinical pharmacist. The registration of different classes of MPE was done according to the National Coordinating Council for Medication Error Reporting and Prevention guidelines. An independent panel evaluated the severity of MPEs. We identified three groups: minor MPEs (no potential to cause harm); intercepted MPEs (potential to cause harm but intercepted on time); and serious MPEs (non-intercepted potential adverse drug events (ADE) or ADEs, being MPEs with potential to cause, or actually causing, patient harm). Results: The C-U and the PB-U each contained 80 patient-days, and a total of 2,510 medication prescriptions were evaluated. The clinical pharmacist identified 375 MPEs. The incidence of MPEs was significantly lower in the C-U compared with the PB-U (44/1286 (3.4%) versus 331/1224 (27.0%); P < 0.001). There were significantly less minor MPEs in the C-U than in the PB-U (9 versus 225; P < 0.001). Intercepted MPEs were also lower in the C-U (12 versus 46; P < 0.001), as well as the non-intercepted potential ADEs (21 versus 48; P < 0.001). There was also a reduction of ADEs (2 in the C-U versus 12 in the PB-U; P < 0.01). No fatal errors occurred. The most frequent drug classes involved were cardiovascular medication and antibiotics in both groups. Patients with renal failure experienced less dosing errors in the C-U versus the PB-U (12 versus 35 serious MPEs; P < 0.001). Conclusion: The ICU computerization, including the medication order entry, resulted in a significant decrease in the occurrence and severity of medication errors in the ICU.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc3983

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 184

Metadata

Authors
Colpaert, K., Claus, B., Somers, A., Vandewoude, K., Robays, H., & Decruyenaere, J.
Venue
Critical Care
Published
2006-01-26
Volume
10
Issue
1
Pages
R21-R21
ISSN
1364-8535 (ISSN-L)
OpenAlex
W1500726896
Cited by
184
References
9
FWCI
18.86
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of computerized physician order entry on medication prescription errors in the intensive care unit: a controlled cross-sectional trial. https://app.cochat.ai/papers/10.1186/cc3983
The paper
Colpaert, K., Claus, B., Somers, A., Vandewoude, K., Robays, H., & Decruyenaere, J. (2006). Impact of computerized physician order entry on medication prescription errors in the intensive care unit: a controlled cross-sectional trial. Critical Care. https://doi.org/10.1186/cc3983

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.