The DOI matches its Crossref record.
Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients
Open accessAbstract
Introduction: Esophageal Doppler provides a continuous and non-invasive estimate of descending aortic blood flow (ABF) and corrected left ventricular ejection time (LVETc). Considering passive leg raising (PLR) as a reversible volume expansion (VE), we compared the relative abilities of PLR-induced ABF variations, LVETc and respiratory pulsed pressure variations (ΔPP) to predict fluid responsiveness. Methods: We studied 22 critically ill patients in acute circulatory failure in the supine position, during PLR, back to the supine position and after two consecutive VEs of 250 ml of saline. Responders were defined by an increase in ABF induced by 500 ml VE of more than 15%. Results: Ten patients were responders and 12 were non-responders. In responders, the increase in ABF induced by PLR was similar to that induced by a 250 ml VE (16% versus 20%; p = 0.15). A PLR-induced increase in ABF of more than 8% predicted fluid responsiveness with a sensitivity of 90% and a specificity of 83%. Corresponding positive and negative predictive values (PPV and NPV, respectively) were 82% and 91%, respectively. A ΔPP threshold value of 12% predicted fluid responsiveness with a sensitivity of 70% and a specificity of 92%. Corresponding PPV and NPV were 87% and 78%, respectively. A LVETc of 245 ms or less predicted fluid responsiveness with a sensitivity of 70%, and a specificity of 67%. Corresponding PPV and NPV were 60% and 66%, respectively. Conclusion: The PLR-induced increase in ABF and a ΔPP of more than 12% offer similar predictive values in predicting fluid responsiveness. An isolated basal LVETc value is not a reliable criterion for predicting response to fluid loading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
Monnet, X., Marik, P., & Teboul, J.-L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4134-1 · Cited by 482
Levitov, A., Frankel, H. L., Blaivas, M., Kirkpatrick, A. W., Su, E., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001847 · Cited by 440
Metadata
- Authors
- Lafanechère, A., Pène, F., Goulenok, C., Delahaye, A., Mallet, V, Choukroun, G., Chiche, J., Mira, J., & Cariou, A.
- Venue
- Critical Care
- Published
- 2006-09-13
- Volume
- 10
- Issue
- 5
- Pages
- R132-R132
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2150428752
- Cited by
- 178
- References
- 0
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. https://app.cochat.ai/papers/10.1186/cc5044
- The paper
- Lafanechère, A., Pène, F., Goulenok, C., Delahaye, A., Mallet, V, Choukroun, G., Chiche, J., Mira, J., & Cariou, A. (2006). Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. Critical Care. https://doi.org/10.1186/cc5044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.