Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Cooling and hemodynamic management in heatstroke: practical recommendations

Open access
Bouchama, Abderrezak, Dehbi, Mohammed, Chaves-Carballo, Enrique·2007·Critical Care

Abstract

Introduction: Although rapid cooling and management of circulatory failure are crucial to the prevention of irreversible tissue damage and death in heatstroke, the evidence supporting the optimal cooling method and hemodynamic management has yet to be established. Methods: A systematic review of all clinical studies published in Medline (1966 to 2006), CINAHL (Cumulative Index to Nursing & Allied Health Literature) (1982 to 2006), and Cochrane Database was performed using the OVID interface without language restriction. Search terms included heatstroke, sunstroke, and heat stress disorders. Results: Fourteen articles reported populations subjected to cooling treatment for classic or exertional heatstroke and included data on cooling time, neurologic morbidity, or mortality. Five additional articles described invasive monitoring with central venous or pulmonary artery catheters. The four clinical trials and 15 observational studies covered a total of 556 patients. A careful analysis of the results obtained indicated that the cooling method based on conduction, namely immersion in iced water, was effective among young people, military personnel, and athletes with exertional heatstroke. There was no evidence to support the superiority of any one cooling technique in classic heatstroke. The effects of non-invasive, evaporative, or conductive-based cooling techniques, singly or combined, appeared to be comparable. No evidence of a specific endpoint temperature for safe cessation of cooling was found. The circulatory alterations in heatstroke were due mostly to a form of distributive shock associated with relative or absolute hypovolemia. Myocardial failure was found to be rare. Conclusion: A systematic review of the literature failed to identify reliable clinical data on the optimum treatment of heatstroke. Nonetheless, the findings of this study could serve as a framework for preliminary recommendations in cooling and hemodynamic management of heatstroke until more evidence-based data are generated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc5910

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 222

Metadata

Authors
Bouchama, A., Dehbi, M., & Chaves-Carballo, E.
Venue
Critical Care
Published
2007-05-12
Volume
11
Issue
3
Pages
R54-R54
ISSN
1364-8535 (ISSN-L)
OpenAlex
W1985289727
Cited by
222
References
3
FWCI
4.75
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cooling and hemodynamic management in heatstroke: practical recommendations. https://app.cochat.ai/papers/10.1186/cc5910
The paper
Bouchama, A., Dehbi, M., & Chaves-Carballo, E. (2007). Cooling and hemodynamic management in heatstroke: practical recommendations. Critical Care. https://doi.org/10.1186/cc5910

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.